Records from 2012 to 2025. Most recent: inspection, 21 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)57.3 ft × 18.3 ft × 3.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2011
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
10 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
21 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8256635
28 July 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8196753
8 September 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7554473
14 February 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7396283
15 January 2020
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6890265
2 July 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6734054
17 July 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6465597
19 July 2017
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6240881
17 October 2016
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6023931
2 August 2016
COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5955971
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 October 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release has expired. Also provide proof of registration sticker.
46 CFR 180.64
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 27 October 2025
Resolved
A vessel must carry either a first aid kit approved under 46 CFR 160.041 or a kit with equivalent contents and instructions. For expiring items, label expiration dates on the outside of the first aid kit.
46 CFR 160.041
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 October 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (2) U.S. Coast Pilot or similar publication.
46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 October 2025
Resolved
Inspection of radiotelephone installation. Every vessel subject to part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years.
47 CFR 80.903
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 July 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection, giving consideration to provisions for a seaworthy hull. <Is discovered multiple cracked welds. 03 welds on loading ramp, 2nd void a longitudinal stringer on the stbd side marked "W" and 4th stringer from top, stbd side.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 July 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A portable hand bilge pump must be: (1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and(2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharge overboard.
46 CFR 182.520
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 July 2018
Resolved
Provide valid COD for vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2018
Resolved 13 September 2018
Resolution: COD on board.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 July 2018
Resolved
Conuct fire and man overboard drills in the presence of a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2018
Resolved 13 September 2018
Resolution: Conducted drills.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2018
Resolved
Provide proof of pre employment testing for crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2018
Resolved 13 September 2018
Resolution: Results provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2018
Resolved
Prove fixed fire fighting system shuts down generator when activated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2018
Resolved 13 September 2018
Resolution: Tested sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 July 2018
Resolved
Provide new battery and hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 13 September 2018
Resolution: verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 July 2018
Resolved
Provide fuel supply and return lines for generator that meet the SAE J1942 standard with J1475 fitted ends.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 10 July 2019
Resolution: Proper install
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 August 2017
Resolved
Conduct drills prior to carrying passengers in the presents of a marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 August 2017
Resolved
Conduct Fire Boy/Engine shutdowns check, pior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2018
Engineering › Non-conventional Propulsion/Steering › Shaft (jet)
Issued 19 July 2017
Resolved
Conduct function check of both Main Diesel Engine
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 July 2017
Resolved
Conduct check of bilge alarms prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 August 2016
Resolved
Provide valid radio telephony safety certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 17 October 2016
Resolution: Received valid certificate
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 August 2016
Resolved
Prove generator shuts down when the pre engineered fixed fire system is activated.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2018
Stability › Watertight Integrity › General
Issued 2 August 2016
Resolved
Renew wasted hose from bow ramp counterweight sump to collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 5 August 2016
Resolution: Pictures of newly installed hose received.