Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named MISS VIRGINIA
MISS VIRGINIA is a 1971 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1994, most recently in November 2025, along with 100 deficiencies and 2 casualty investigations between 2002 and 2010.
Records from 1994 to 2025. Most recent: inspection, 13 November 2025.
- Built
- 1971
- Last inspected
- 13 November 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 100 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2002–2010
Identity
535723
WDF2104
111508
Flag
UNITED STATES
367424930
Maury page id
psix-111508
Inspections, by type
…with no type recorded8
Years with a record
29 calendar years (1994–2025)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)49.9 ft × 16.4 ft × 5.2 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCLEARWATER BAY MARINE WAY · CLEARWATER, FL, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTARPON SPRINGS, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF2104MMSI 367424930 · active · compulsorily equipped · granted 5 September 2019, expires 10 September 2029
WCB2067MMSI not assigned · expired · compulsorily equipped · granted 25 November 1998, cancelled 20 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
13 November 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8228037
1 May 2025
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8082203
6 January 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8058614
9 February 2024
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7856172
2 May 2023
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7644995
8 February 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7622577
15 July 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7457990
2 February 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7384295
12 May 2021
Deficiency Check · In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7184141
5 November 2020
In-Service Inspection · Deficiency Check · COI Inspection · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7078479
14 November 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6853597
17 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6835689
2 October 2018
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6517814
1 May 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6386057
7 November 2017
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6303258
21 November 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6028480
26 April 2016
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5858414
8 September 2015
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5238190
5 May 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4851928
23 May 2012
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4342180
20 December 2011
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4212146
28 September 2010
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3858261
3 September 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3316947
6 May 2008
Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3201556
29 March 2008
Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 3173828
5 June 2006
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2666951
8 May 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2640138
7 July 2005
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2416648
15 September 2004
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2191225
11 May 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2059713
23 October 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1938557
12 September 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1896501
29 January 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1737061
17 September 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1674372
14 May 2002
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1613219
18 January 2002
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480203
17 January 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1483628
11 June 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391591
1 October 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057741
19 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427891
23 May 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376220
7 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 215904
28 March 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 117233
16 December 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 812790
19 August 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470224
5 April 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808069
2 August 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 180276
22 June 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1440019
3 June 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429018
26 May 1998
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1126974
26 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 86633
25 July 1997
Re-Inspection · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407945
15 July 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1359212
24 May 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1367841
12 March 1996
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078870
11 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 175180
9 November 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 98329
8 June 1995
Plan Review "T" Boat · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146330
13 December 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 882172
7 November 1994
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867790
Deficiency record · 100
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 November 2025
Resolved
Each item of survival craft equipment must be stored in a way that does not interfere with launching.
Life floats tethered together using improperly sized line. Tether must be replaced utilizing a length of line that will reach the waterline from the stowage position.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 November 2025
Resolved
Rotating machinery must be properly protected by a cover, guard, or rail. Both main engines must have the belt guards installed to the satisfaction of the MI.
46 CFR 177.960
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2025
Resolved
The intent of this part is to insure that all machinery be installed and maintained in such a manner as to
afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed missing insulation/lagging from the port side main engine turbo. Repair to satisfaction of CG inspectors.
46 CFR 182.01-5(a)
701c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2025
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed leaking hydraulic lines connected to main steering ram. Repair to satisfaction of CG inspectors.
46 CFR 182.30-1(a)
701c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2025
Resolved
The intent of this part is to insure that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed missing double hose clamps on nonmetallic fuel lines connected to main engines and generator. Repair to satisfaction of CG inspectors.
46 CFR 182.01-5(a)
701c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2025
Resolved
46 CFR 181.420(a)(3)
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Installed system does not shutdown generator. Repair to satisfaction of CG inspectors.
CODE 705: Vessel is restricted from operating the generator while passengers are on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2025
Resolved
46 CFR 182.01-5
"Old T"
All machinery be installed and maintained in such a manner as to afford adequate protection against fire,
explosion, machinery failure and personnel injury. MI observed deteriorated generator fuel supply line. Repair to the satisfaction of CG inspectors.
CODE 705: Generator can't be operated until fuel line is replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 6 February 2025
Resolved
46 CFR 182.01-5(a)
"Old T"
The intent of this part is to insure that all machinery be installed and maintained in such a manner as to afford adequate protection against personnel injury. MI observed missing belt guards covering rotating machinery on port and stbd main engines. Repair to satisfaction of CG inspectors.
CODE 705: Make repairs within 7 days of inspection
(NLT 13FEB2025).
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 February 2025
Resolved
46 CFR 176.810(b)(1)(iv)
The required fire extinguisher maintenance shall be logged. Monthly maintenance was being performed. Update maintenance logs to the satisfaction of CG inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2025
Resolved
46 CFR 185.364
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. MI observed lack of crew and passenger instruction for the handling, storage, and operation of rechargeable batteries contained in cell phones.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 6 February 2025
Resolved
33 CFR 159.7 (C)
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. MI observed sewage overboard valves in the open position.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2024
Resolved
A vessel must carry one floating waterlight, unless it
is limited to daytime operation, in which case no
floating waterlight is required.
Floating waterlight is inoperative.
Repair or replace light. Operations restricted to daylight only.
46 CFR 180.70(d)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2024
Resolved
Each ring life buoy with a floating waterlight must have
a lanyard of at least 910 millimeters (3 feet) in
length, but not more than 1,830 millimeters (6 feet),
securing the waterlight around the body of the ring life
buoy.
Floating waterlight lanyard is not at least 3 feet in length.
46 CFR 180.70(d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2024
Resolved
On a vessel carrying only one ring buoy, the floating
waterlight must be attached to the lanyard with a
corrosion-resistant clip. The clip must have a strength
of at least 22.7 kilograms (50 pounds), and allow the
waterlight to be quickly disconnected from the ring life
buoy.
Clip found to be deteriorated.
46 CFR 180.70(d)(3)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2024
Resolved
Machinery and equipment installed on each vessel must be
suitable for the vessel and its operation and for the
purpose intended. All machinery and equipment must be
installed and maintained in such a manner as to afford
adequate protection from causing fire, explosion,
machinery failure, and personnel injury.
Forward emergency fuel shut-off valve's packing is no longer
sufficient to ensure no fuel leaks out of the valve stem.
Valve to be repacked or replaced.
46 CFR 182.100
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 February 2024
Resolved
An exposed hazard, such as gears or rotating machinery,
must be properly protected by a cover, guard, or rail.
Both main diesel engine accessory drive and belts do not
have guards around them.
Install guards around belts.
46 CFR 177.960
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2024
Resolved
Each battery must be located as high above the bilge as
practicable, secured to protect against shifting with
the roll and pitch of the vessel, and free from exposure
to water splash or spray.
Generator battery found to be unsecured and not covered.
Battery to be firmly secured and covered to prevent water splash.
46 CFR 183.350(b)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 February 2024
Resolved
First aid kit is expired.
Replace first aid kit with an approved type kit.
46 CFR 160.041
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 February 2024
Resolved
Each life jacket carried on a vessel on a oceans route must have a life jacket light.
11 adult life jackets lights found inoperable.
46 CFR 180.75
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 February 2024
Resolved
The Certificate of Inspection and any SOLAS Certificates
must be posted under glass or other suitable transparent
material, such that all pages are visible, in a
conspicuous place on the vessel where observation by
passengers is likely. If posting is impracticable, such
as in an open boat, the certificates must be kept on
board in a weathertight container readily available for
use by the crew and display to passengers and others on
request.
COI not posted; post COI as indicated above.
46 CFR 176.302
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2024
Resolved
When, in accordance with § 178.210 of this chapter, a
vessel must be provided with a stability letter, the
stability letter must be posted under glass or other
suitable transparent material, such that all pages are
visible, at the operating station of the vessel. If
posting is impracticable, the stability letter must be
kept on board in a weathertight container readily
available for use by the crew and display to passengers
and others on request.
Stability letter not posted; post stability letter as indicated above.
46 CFR 176.306
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2023
Resolved
Each life preserver carried on a vessel engaged in ocean, coastwise, or Great Lakes service after June 30, 1980, must have a personal flotation device light that is approved under subpart 161.012 of this chapter.
MI observed 05 child life preservers were outfitted with inoperable lights.
Vessel route is restricted to limited coastwise.
46 CFR 180.25-20
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
MI observed vessel was only outfitted with 02 alcohol testing devices. When underway for overnight voyages, vessel sails with 04 crewmembers.
Vessel route is restricted to limited coastwise.
46 CFR 4.06-15(a)(1)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2023
Resolved
The marine employer must have a sufficient number of urine-specimen collection and shipping kits meeting the requirements of 49 CFR Part 40 that are readily accessible for use following SMIs.
MI observed no acceptable urine-specimen collection and shipping kits onboard.
Vessel route is restricted to limited coastwise.
46 CFR 4.06-15(b)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2023
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Per the table, vessel is required to have 1 fixed power pump and 1 portable hand pump.
MI observed that vessel did not have a portable hand pump onboard.
Rectify within 7 days.
46 CFR 182.25-10(a)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2023
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway.
MI observed strength and general condition of painter for life floats was significantly deteriorated due to exposure.
46 CFR 185.700(a)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 February 2023
Resolved
Paddles shall be lashed on the sides of the life floats to which they belong.
MI observed paddles were not secured to life floats.
46 CFR 180.15-10
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 February 2023
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel.
MI observed that EAP training had not been conducted for any of the crewmembers.
46 CFR 16.401(b)
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 February 2023
Resolved
The master of the vessel shall ensure that: Each EPIRB...must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative.
MI observed that log entries did not indicate EPIRB testing monthly and vessel rep confirmed testing was not completed on a monthly basis.
46 CFR 185.728(a)
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 17 October 2019
Resolved
Vessel is restricted from carrying overnight passengers until plans from owner are approved and completed repairs and maintenance are inspected by an attending marine inspector. Cited under 46 CFR 177.202 Plans and information required / 46 CFR 177.810 Overnight accommodations.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 2 October 2018
Resolved
Vessel must be in compliance with this subpart. Wood keel forward of fuel tank has considerable rot. Renew wasted and rotted material. - 46CFR176.25-1
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 October 2018
Resolved
Each Buoyant Apparatus must be fitted with a life line. Life line on buoyant apparatus wasted. Replace life line. - 46CFR180.175(e)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 October 2018
Resolved
Each port light with sill located below margin line must have hinged, inside dead cover. Port side missing cover and bolts. Replace dead cover and bolts. - 46CFR171.117
Construction/Loadline › Hull › Keel
Issued 1 May 2018
Resolved
0983 - Proposed alterations shall be approved by the OCMI before work is started. Submit a repair proposal for the rotted section of wood on the aft keel. - 46CFR176.20-1(b)
Communications › Radio Communications › VHF Radiotelephone
Issued 21 November 2016
Resolved
Place MMSI in VHF-DSC Radio and ensure GPS is also hooked into the VHF-DSC Radio and have FCC Certified Tech verify proper instalation.
Engineering › Steering Gear System › Bracket/Clamp
Issued 26 April 2016
Resolved
Repair flexible clamps on port and starboard stuffing boxes.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 26 April 2016
Resolved
Replace Transducer mounts on port side.
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2016
Resolved
Repair port side splash rail to satisfaction of Marine Inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 10 September 2015
Resolved
Restrict passenger carriage to 49 passengers until the vessel complies with the fixed fire pump requirements found in 46 CFR 181.300(b).
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 8 September 2015
Resolved
The vessel is not fitted with a rescue platform. Provide proof of a fitted rescue platform. NOTE: the O/O was emailed a copy of the local CID memo that dictates the build requirements for the rescue platform.
Engineering › Bilge Water Management System › Valve
Issued 8 September 2015
Resolved
The port side bilge pump is not fitted with a positive shutoff valve installed at the hull penetration IAW 46 CFR 182.520(e)(7). Provide proof that a valve is installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 September 2015
Resolved
The remote fuel shutoff station must be provided with signs/directions of how to properly operate the valve. Provide directions IAW 46 CFR 185.608.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2015
Resolved
Provide a first-aid kid that complies with 46 CFR 184.710.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2010
Resolved
Provide eyewash and ammonia inhalants for First Aid Kit.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 September 2010
Resolved
Provide 3 additional adult Type I PFD's. Vsl is restricted to 63 total persons until completed.
Stability › Unintentional Flooding › General
Issued 28 September 2010
Resolved
Install gaskets on fwd escape hatch and engine room access.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 28 September 2010
Resolved
Provide new modular smoke detector for overnight accommodation space. Vsl is restricted from overnight accommodations.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 September 2010
Resolved
Provide MF radio. Vsl is restricted to trips of no more than 20 NM.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 3 September 2008
Resolved
Make repairs to MF radio, will not transmit or receive. Vsl is reduced to 20 NM until repairs are made.
Lifesaving › Buoyant Apparatus › Marking
Issued 5 June 2006
Resolved
Stencil the paddles for all life floats with vessel name.
Communications › Radio Communications › EPIRB
Issued 5 June 2006
Resolved
Provide the proper type of hydrostatic release for the EPIRB.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 June 2006
Resolved
Provide the vessel with an appropriate alcohol test kit for testing within 2 hours of a SMI.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 July 2005
Resolved
Prior to utilizing your overnight accommodations, provide a smoke detector that meets 46CFR181.450(a)(1). They had installed house hold fir detectors in accommodation space.
Engineering › Fuel Oil Service System › Valve
Issued 7 July 2005
Resolved
Label emergency fuel oil shut off valves. Seats were painted and there was no way to identifying the shut off valves.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 July 2005
Resolved
Re-label all life preserver stowage areas as discussed. Labels have worn off and un-readable.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 July 2005
Resolved
Re-mount safety shields by bilge pump. They had removed the safety shield to work on pump and alternator and did not replace shield. The bilge manifold is under the pump pulley and could cause injury if a crewmember fell into it.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 7 July 2005
Resolved
Re-pack PORT shaft stern tube. Shaft is leaking and the packing nut is bottomed out. O/O has packing onboard and will replace today.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 September 2004
Resolved
REPLACE PORT/STBD RUNNING LIGHT LENSES.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 15 September 2004
Resolved
REPLACE WATER FILLED WATERLIGHT ON STARBOARD LIFEFLOAT PRIOR TO CARRIAGE OF PASSENGERS.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 2004
Resolved
REPAIR GLOBE ON AFT STARBOARD STERN LIGHTING.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 15 September 2004
Resolved
REPLACE RETRO ON LIFEFLOATS AS NEEDED.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 September 2004
Resolved
Owner/operator failed to make vessel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI.
Construction/Loadline › Hull › Bracket
Issued 11 May 2004
Resolved
PROVIDE DEAD LIGHT COVERS ON ALL WINDOWS BELOW MAIN DECK.
Construction/Loadline › Penetrations
Issued 12 September 2003
Resolved
Plug/cap through hull valve located in FWD berthing area. LEGACY COMPONENT DESC: Valve Flange
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 12 September 2003
Resolved
Label both sides of emergency escape hatch. LEGACY COMPONENT DESC: FWD berth
Engineering › Bilge Water Management System
Issued 12 September 2003
Resolved
Label bilge manifold. LEGACY COMPONENT DESC: Manifold
Accommodation/Occupational Safety › Occupational Safety
Issued 12 September 2003
Resolved
Replace safety shields over pulley assy. IWO BMDE's, FWD. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Engineering › Bilge Water Management System
Issued 12 September 2003
Resolved
Replace valve for engine room pick-up, on bilge manifold prior to the carriage of passengers. LEGACY COMPONENT DESC: Manifold
Engineering › Bilge Water Management System
Issued 12 September 2003
Resolved
Double hose clamp hose from bilge/fire pump discharge. LEGACY COMPONENT DESC: Hose
Electrical › Electrical Distribution System (service)
Issued 12 September 2003
Resolved
Replace door for battery charger fuse box. LEGACY COMPONENT DESC: Distribution Panel Bus
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 September 2003
Resolved
Relocate one B-II portable fire extinguisher out from engine room. LEGACY COMPONENT DESC: Location
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 September 2003
Resolved
Repair GENSET so it will shut down via the FFFE system. LEGACY COMPONENT DESC: Operating Controls
Engineering › Fuel Oil Service System
Issued 12 September 2003
Resolved
Repair emergency fuel shut down valve. (Linkage would not close valve) LEGACY COMPONENT DESC: Valve, Control
Construction/Loadline › Penetrations
Issued 12 September 2003
Resolved
Plug 1" hole in FWD engine room BLKHD, IWO bilge/keel area. LEGACY COMPONENT DESC: BLKHD
Lifesaving › Buoyant Apparatus
Issued 12 September 2003
Resolved
Replace retro-reflective tape on life ring and the top life float. LEGACY COMPONENT DESC: Retro-reflective tape
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 September 2002
Resolved
REPAIR GENSET SHUT DOWN FOR FIXED FIRE SYSTEM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Operating Controls
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 September 2002
Resolved
REPAIR SHORT IN STARBOARD STARTER PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Starter
Communications › Radio Communications
Issued 17 September 2002
Resolved
REPLACE HYDROSTATIC RELEASE ON 406MHZ EPIRB PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: EPIRB
Operations/Management › Pollution
Issued 17 September 2002
Resolved
POST GARBAGE PLACARD. LEGACY COMPONENT DESC: Control of Garbage
Lifesaving › Hand Flares
Issued 17 September 2002
Resolved
PROVIDE 12 DAY/NIGHT HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS LEGACY COMPONENT DESC: Condition
Construction/Loadline › Hull › Hull Plating
Issued 14 May 2002
Resolved
Arrest rot around port shaft packing.
Construction/Loadline › Hull › Bottom Plating
Issued 14 May 2002
Resolved
Arrest rot around port and starboard rudder packings.
Stability › Watertight Integrity
Issued 14 May 2002
Resolved
Replace/Cap off thru-hull on portside rudder compartment. LEGACY COMPONENT DESC: Sideshell Pentration
Operations/Management
Issued 14 May 2002
Resolved
Conduct a satisfactory sea trial of vessel with a marine inpector in attendace prior to operation.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 January 2002
Resolved
Submit a CG-2692, ASAP. to MSO Tampa attention Investigation Department. LEGACY COMPONENT DESC: Deck Rail
Accommodation/Occupational Safety › Occupational Safety
Issued 18 January 2002
Resolved
Repair stern gunnel. LEGACY COMPONENT DESC: Deck Rail
Engineering
Issued 19 September 2000
Resolved
REPAIR EXHAUST LEAK ON STBD MDE EXHAUST PIPING.
Lifesaving
Issued 19 September 2000
Resolved
PROVIDE PROOF OF CERTIFICATION OF 50% OF CREW IN FIRST AID/CPR.
Construction/Loadline
Issued 23 May 2000
Resolved
CONDUCT SEA TRAILS OF THE VESSEL WITH MARINE INSPECTOR ON BOARD TO WITNESS VESSEL WORKING IN THE SEA.
Fire Fighting
Issued 5 April 1999
Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING EXTINGUISHING SYSTEM AT NEXT COAST GUARD INSPECTION.
Lifesaving
Issued 22 June 1998
Resolved
Replace expired signaling devices (flares/smokes) prior to sailing.
Electrical
Issued 22 June 1998
Resolved
Provide Generator and Motor nameplates prior to placing Ship Service Generator in service.
Construction/Loadline
Issued 22 June 1998
Resolved
Provide sufficient length of suction hose to portable hand pump capable of reaching bilge and descharging overboard.
Electrical
Issued 22 June 1998
Resolved
Install emergency lighting in accomodation spaces prior to carriage of passengers in accomodation spaces._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 June 1998
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL CAP ON THROUGH HULL FITTING PORTSIDE F/O TANK SPACE.
Documentation
Issued 3 June 1998
Resolved
SUBMIT LETTER REQUESTING APPROVAL OF CURRENT DEAD LIGHT CONFIGURATION OR APPROVAL OF A NEW CONFIGURATION.
Electrical
Issued 25 July 1997
Resolved
PROVIDE APPROVAL LETTER FOR EMERGENCY GASOLINE GENERATOR INSTALLED ON UPPERDECK OF VESSEL.
Fire Fighting
Issued 15 July 1996
Resolved
SERVICE PORTABLE F/E'S PRIOR TO THE CARRIAGE OF PASSENGERS.
Documentation
Issued 15 July 1996
Resolved
PROVIDE PROOF OF CONSORTIUM MEMBERSHIP FOR SECOND DECKHAND.
Lifesaving
Issued 15 July 1996
Resolved
INSTALL SPACERS BETWEEN STACKED LIFEFLOATS.
Casualty record · 2
17 January 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1483628
23 July 2010Routine · role: Involved in a Marine Casualty · activity 3803813
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.