MSC DIVINA
MSC DIVINA is a 2012 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2014, most recently in November 2025, along with 26 deficiencies and 4 operational controls.
Records from 2014 to 2025. Most recent: inspection, 3 November 2025.
- Built
- 2012
- Last inspected
- 3 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9585285 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FFA5
1115347
Flag
PANAMA
—
Maury page id
psix-1115347
Inspections, by type
…with no type recorded3
Years with a record
12 calendar years (2014–2025)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it135000 - Regulatory (Subpart C or D), Gross Ton
139072 - Convention (Subpart B), Gross Ton
12198 - Dead Weight, Ton
67238 - Displacement, Ton
139072 - Convention (Subpart B), Gross Ton
12198 - Dead Weight, Ton
67238 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
3 November 2025
COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8261121
22 November 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038720
18 November 2024
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8036050
18 February 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7867032
25 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855659
11 December 2023
COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7837308
26 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7676227
10 March 2023
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7646803
10 March 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7648902
18 August 2022
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7533890
13 February 2022
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7391678
25 August 2021
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7277604
7 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6936427
22 November 2019
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6857470
24 October 2018
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565968
24 October 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6567746
28 October 2017
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6296276
3 May 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6137078
22 March 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6127662
9 November 2016
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6034681
27 April 2016
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5863084
4 April 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5846782
9 March 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5829875
21 January 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5800899
21 November 2015
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5767194
2 November 2015
COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5755394
2 August 2014
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4941726
7 May 2014
COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4842238
Deficiency record · 26
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 November 2025
Resolved
The width of corridors, doorways and stairways which form
part of the evacuation paths shall be not less than 900 mm for passenger craft and 700 mm for cargo craft. This width maybe reduced to 600 mm for corridors, doorways and
stairways serving spaces where persons are not normally
employed. There shall be no protrusions in evacuation paths
which could cause injury, ensnare clothing, damage
lifejackets or restrict evacuation of disabled persons.
Requirements of this paragraph do not apply to aisles (fore-aft passageways separating seating areas) or to spaces
between adjacent rows of seats. However, the width of aisles
and the seat pitch shall be such as to allow the craft to comply with the provisions of 4.8. Observed obstructed means of escape in MVZ4/Deck 4 Crew stairs, Perfum & Liquor
Room, and Laundry Room.
74 SOLAS 2O X/3 HSC Code 4.7.13
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 November 2025
Resolved
The construction of doors and door frames in 'A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire Doors FD04211, FD044102, FD04203, FD05303, and FD06307 did not close completely.
74 SOLAS 20 II-2/9.4.1.1.2
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 November 2024
Resolved
The emergency source of electrical power may be either a generator or an accumulator battery, which shall comply with the following: started automatically upon failure of the electrical supply from the main source of electrical power...
PSCOs received report the vessels transitional UPS system had malfunctioned, resulting in the emergency generator not being able to automatically start in case of an emergency.
74SOLAS Cons. 2020 II-1/42.3.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2024
Resolved
Fire Doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 305 degrees opposing closure. PSCO observed 05 fire doors that failed to close and latch completely. The doors are, FD 16307, FD 13804, FD 05705, FD 05707, and FD 06402.
74 SOLAS 20 II-2/9.4.1.1.5.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 November 2024
Resolved
Control handles shall be provided at each side of the bulkhead at a minimum height of 1.6m above the floor and shall be so arranged as to enable persons passing through the doorway to hold both handles in the open position without being able to set the power closing mechanism in operation accidentally. The direction of movement of the handles in opening and closing the door shall be in the direction of door movement and shall be clearly indicated. PSCOs observed that after activating one of the handles for the watertight door 401 it failed to operated and close.
74 SOLAS 04 II-1/15.7.4
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 18 November 2024
Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or floating platforms shall carry a garbage management plan which the crew shall follow. PSCO observed a garbage bin located in the theater changing area by door 05105 that was being used incorrectly by having food, plastic, metal, and paper waste products when is should only have had paper products.
MARPOL 2017 Annex V/10.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2024
Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Within the medical center, PSCOs observed medical equipment incorrectly stored in the hallway leading to the exit.
74 SOLAS 20 II-2/13.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. Crew stair 38 double leaf fire door 04403 closes both doors in 5 seconds from start of movement.
74 SOLAS 20 II-2/9.4.1.1.5.2
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 December 2023
Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Vessel does not have testing procedures for the oily water separator.
MARPOL 2017 Annex I/14.2 MEPC.107(49) Annex 13.6.1
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 December 2023
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The means of closing shall be easily accessible as well as prominently and permanently marked and shall indicate whether the shut-off is open or closed. Port bow thruster space ventilation fire damper does not remotely actuate.
74 SOLAS 20 II-2/5.2.1.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire doors 02203, 05710, 05802, 06707, and 16209 did not fully close when opened fully and released.
74 SOLAS 20 II-2/9.4.1.1.5.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, hold-back hooks not subject to central control station release are prohibited. Interior fire door 17302 to lift machine space in AC room 573 held open by chain and unattended.
74 SOLAS 20 II-2/9.4.1.1.5.4
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 December 2023
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks shall be as prescribed in tables 9.1 and 9.2 AC room 452 has several cardboard boxes of new AC filters stowed within the space.
74 SOLAS 20 II-2/9.2.2.3.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2023
Resolved
Each NOA must contain all of the information items specified in Tale 160.206 ... (6) Operational condition of equipment. Vessel's AIS does not receive signals from other vessels, transmits signals intermittenly, and also does not communicate with the VDR System. Vessel has a condition of Class, and this Condition of Class states that vessel shall notify all concerned parties. The vessel did not notify the United States by reporting it on their Notice of Arrival.
33 CGR 160.206(a)(6)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 August 2022
Resolved
07105 - Fire Doors/Openings - The approximate uniform rate of closure for sliding doors shall be of no more than 0.2 m/s and no less than 0.1 m/s with the ship in upright position. Fire door 14315 did not close completely, stopping halfway after multiple tries.
74 SOLAS - 20 II-2/9.4.1.1.5.2
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 August 2021
Resolved
07105-Fire Safety- Fire doors in main vertical bulkheads, galley boundaries and stairway enclosures... shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCOs observed galley door 14613 unable to fully close. - 74 SOLAS 09 con. II-2/1.1.4.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 August 2021
Resolved
07199-Fire Safety- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to limit the accumulation of flammable vapours. PSCOs observed the accumulation of diesel fuel in the engine bilge compartments of lifeboats 5, 6, 8, and 12. - 74 SOLAS 09 con. II-2/4.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 October 2018
Resolved
Prior to ship leaving port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Tender #31 STBD engine will not set to neutral.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2018
Resolved
There shall not be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape. Food store deck door to aft mooring station is locked and is the second means of escape. (Deck 4 frame 4 area)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2018
Resolved
Electrical installations shall be suchthat the safety of persons, crew, and ship from electrical hazards will be ensured. 04 ground wires found not connected to rudder angle indicatorsin steering rooms.
Engineering › Thrusters › Motor
Issued 21 January 2016
Resolved
1499 - The condition of rhe ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons on board. Vessel's stern thruster #1 found to have a ground within its motor, stern thruster inoperable. 74SOLAS(2009) CH.I/Reg 11(a)
Lifesaving › Lifeboat › Propulsion Engine
Issued 7 November 2015
Resolved
Passenger ships engaged on international voyages which are not short international voyages shall carry... lifeboats complying with the requirements of section 4.5 or 4.6 of the code on each side... lifeboat #13 is not operational due to starting motor failure. The ships maximum number of passengers has been reduced from 4345 to 4145 based on amended PSSC issued by B.V.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 7 November 2015
Resolved
The construction of doors and door frames in "A" class divisions with the means of securing them when closed. Shall provide resistance to fire and smoke. FD's 13803, 13804, 12702, 1071, 05802 and FSD 14802 did not latch.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 November 2015
Resolved
Furniture in stairway enclosures shall be limited to seating... A linen cart is geing stowed in the galley stair, Aft on Deck 6.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 7 November 2015
Resolved
Flammable storage item found stored in port side theatre store room, carpenter shop, and upolstry shop. Flammable liquids shall be stored in category 14 spaces.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 November 2015
Resolved
In addition to the emergency lighting required by regulations II-1-42 and III / 11.5, the means of escape, including stairways and exits, shall be marked by lighting.. The exit sign in the simulator room is not illuminating by electric power.