MSC DIVINA

MSC DIVINA is a 2012 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in November 2025, along with 21 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 3 November 2025.

Built
2012
Last inspected
3 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 November 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9585285
1115347
Flag
PANAMA
Maury page id
psix-1115347

Documentation record

Tonnage as PSIX records it135000 - Regulatory (Subpart C or D), Gross Ton
139072 - Convention (Subpart B), Gross Ton
12198 - Dead Weight, Ton
67238 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

3 November 2025 COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8261121
22 November 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038720
18 November 2024 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8036050
18 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7867032
25 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855659
11 December 2023 COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7837308
26 April 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7676227
10 March 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7646803
10 March 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7648902
18 August 2022 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7533890
13 February 2022 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7391678
25 August 2021 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7277604
7 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6936427
22 November 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6857470
24 October 2018 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565968
24 October 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6567746
28 October 2017 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6296276
3 May 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6137078
22 March 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6127662
9 November 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6034681
27 April 2016 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5863084
4 April 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5846782
9 March 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5829875
21 January 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5800899

Deficiency record · 21

09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 November 2025 Resolved
The width of corridors, doorways and stairways which form part of the evacuation paths shall be not less than 900 mm for passenger craft and 700 mm for cargo craft. This width maybe reduced to 600 mm for corridors, doorways and stairways serving spaces where persons are not normally employed. There shall be no protrusions in evacuation paths which could cause injury, ensnare clothing, damage lifejackets or restrict evacuation of disabled persons. Requirements of this paragraph do not apply to aisles (fore-aft passageways separating seating areas) or to spaces between adjacent rows of seats. However, the width of aisles and the seat pitch shall be such as to allow the craft to comply with the provisions of 4.8. Observed obstructed means of escape in MVZ4/Deck 4 Crew stairs, Perfum & Liquor Room, and Laundry Room. 74 SOLAS 2O X/3 HSC Code 4.7.13
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
Resolution: Crew cleared obstructed areas.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 November 2025 Resolved
The construction of doors and door frames in 'A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire Doors FD04211, FD044102, FD04203, FD05303, and FD06307 did not close completely. 74 SOLAS 20 II-2/9.4.1.1.2
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
Resolution: Crew adjusted locking mechanism, PSCO verified proper operations of FDs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 November 2024 Resolved
The emergency source of electrical power may be either a generator or an accumulator battery, which shall comply with the following: started automatically upon failure of the electrical supply from the main source of electrical power... PSCOs received report the vessels transitional UPS system had malfunctioned, resulting in the emergency generator not being able to automatically start in case of an emergency. 74SOLAS Cons. 2020 II-1/42.3.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2024
Resolved 9 December 2024
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2024 Resolved
Fire Doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 305 degrees opposing closure. PSCO observed 05 fire doors that failed to close and latch completely. The doors are, FD 16307, FD 13804, FD 05705, FD 05707, and FD 06402. 74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2024
Resolution: Resolved on the spot during the exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 November 2024 Resolved
Control handles shall be provided at each side of the bulkhead at a minimum height of 1.6m above the floor and shall be so arranged as to enable persons passing through the doorway to hold both handles in the open position without being able to set the power closing mechanism in operation accidentally. The direction of movement of the handles in opening and closing the door shall be in the direction of door movement and shall be clearly indicated. PSCOs observed that after activating one of the handles for the watertight door 401 it failed to operated and close. 74 SOLAS 04 II-1/15.7.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2024
Resolution: Resolved during the exam.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 18 November 2024 Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or floating platforms shall carry a garbage management plan which the crew shall follow. PSCO observed a garbage bin located in the theater changing area by door 05105 that was being used incorrectly by having food, plastic, metal, and paper waste products when is should only have had paper products. MARPOL 2017 Annex V/10.2
Action required: 10 - Deficiency Rectified
Resolved 18 November 2024
Resolution: Resolved during the exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2024 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Within the medical center, PSCOs observed medical equipment incorrectly stored in the hallway leading to the exit. 74 SOLAS 20 II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 18 November 2024
Resolution: Resolved during the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. Crew stair 38 double leaf fire door 04403 closes both doors in 5 seconds from start of movement. 74 SOLAS 20 II-2/9.4.1.1.5.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 11 December 2023
Resolution: Door closure devices adjusted. Door closure test results: 12 seconds.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 December 2023 Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Vessel does not have testing procedures for the oily water separator. MARPOL 2017 Annex I/14.2 MEPC.107(49) Annex 13.6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2024
Resolved 18 February 2024
Resolution: BV Letter of Attestation for the equipment. See Documents Tab of Activity 7867032.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 December 2023 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The means of closing shall be easily accessible as well as prominently and permanently marked and shall indicate whether the shut-off is open or closed. Port bow thruster space ventilation fire damper does not remotely actuate. 74 SOLAS 20 II-2/5.2.1.1
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Remote actuation mechanism troubleshot and tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire doors 02203, 05710, 05802, 06707, and 16209 did not fully close when opened fully and released. 74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Door closure mechanisms adjusted and retested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, hold-back hooks not subject to central control station release are prohibited. Interior fire door 17302 to lift machine space in AC room 573 held open by chain and unattended. 74 SOLAS 20 II-2/9.4.1.1.5.4
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Chain removed from door.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 December 2023 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks shall be as prescribed in tables 9.1 and 9.2 AC room 452 has several cardboard boxes of new AC filters stowed within the space. 74 SOLAS 20 II-2/9.2.2.3.1
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Stowed materials removed from space and properly stowed in adequately rated space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2023 Resolved
Each NOA must contain all of the information items specified in Tale 160.206 ... (6) Operational condition of equipment. Vessel's AIS does not receive signals from other vessels, transmits signals intermittenly, and also does not communicate with the VDR System. Vessel has a condition of Class, and this Condition of Class states that vessel shall notify all concerned parties. The vessel did not notify the United States by reporting it on their Notice of Arrival. 33 CGR 160.206(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 March 2023
Resolved 10 March 2023
Resolution: Rectified on the spot and issued LOD.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 August 2022 Resolved
07105 - Fire Doors/Openings - The approximate uniform rate of closure for sliding doors shall be of no more than 0.2 m/s and no less than 0.1 m/s with the ship in upright position. Fire door 14315 did not close completely, stopping halfway after multiple tries. 74 SOLAS - 20 II-2/9.4.1.1.5.2 74 SOLAS 20 II-2/9.4.1.1.5.2
Action required: 10 - Deficiency Rectified
Resolved 18 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 August 2021 Resolved
07105-Fire Safety- Fire doors in main vertical bulkheads, galley boundaries and stairway enclosures... shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCOs observed galley door 14613 unable to fully close. - 74 SOLAS 09 con. II-2/1.1.4.1
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 August 2021 Resolved
07199-Fire Safety- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to limit the accumulation of flammable vapours. PSCOs observed the accumulation of diesel fuel in the engine bilge compartments of lifeboats 5, 6, 8, and 12. - 74 SOLAS 09 con. II-2/4.1.2
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 October 2018 Resolved
Prior to ship leaving port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Tender #31 STBD engine will not set to neutral.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2018 Resolved
There shall not be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape. Food store deck door to aft mooring station is locked and is the second means of escape. (Deck 4 frame 4 area)
Action required: 10 - Deficiency Rectified
Resolved 24 October 2018
Resolution: Resolved prior to end of exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2018 Resolved
Electrical installations shall be suchthat the safety of persons, crew, and ship from electrical hazards will be ensured. 04 ground wires found not connected to rudder angle indicatorsin steering rooms.
Action required: 10 - Deficiency Rectified
Resolved 24 October 2018
Resolution: Fixed prior to end of exam.
Engineering › Thrusters › Motor
Issued 21 January 2016 Resolved
1499 - The condition of rhe ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons on board. Vessel's stern thruster #1 found to have a ground within its motor, stern thruster inoperable. 74SOLAS(2009) CH.I/Reg 11(a)
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 4 April 2016
Resolution: 4 Apr 2016: Class submitted report to CG, def cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.