EUROPA 2

EUROPA 2 is a 2013 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2016, most recently in December 2025, along with 7 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 11 December 2025.

Built
2013
Last inspected
11 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9616230
9HA3283
1115360
Flag
MALTA
Maury page id
psix-1115360

Documentation record

Tonnage as PSIX records it42830 - Convention (Subpart B), Gross Ton
14406 - Convention (Subpart B), Net Ton
22400 - Displacement, Ton
5285 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

11 December 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8281905
4 April 2025 COC-CVE Annual · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8100045
4 April 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8106595
24 May 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7918268
31 March 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7886703
17 October 2023 COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7807701
25 November 2019 COC-CVE Initial · ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6861574
24 October 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6293881
25 September 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6006520

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 December 2025 Resolved
The widths, number and continuity of escapes shall be in accordance with the requirements in Fire Safety Systems Code. Shall not be less than 900 mm in clear with. The minimum clear width shall be increased by 10 mm for every one person provided in excess of 90 persons. PSCO observed tables in the port side dining area of Yacht Club, obstructing the egress route by minimizing the width of means of escape. 74 SOLAS (09) II-2 / 13.3.2.4.5, FSS CODE 13.2.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 11 December 2025
Resolution: Tables were moved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2025 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of teh fire safety measures the ship provided with. for this purpose, the following functional requirements shall be met: 1, fire protection systems and fire-fighting systems and applainces shall be maintained ready for use; and 2. fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. While testing the automatic release capabilities of teh hi-fog system for the incinerator, the main valve inside the section valve bank was found in the closed position. 74 SOLAS 20 II-2/14.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2025
Resolution: Crew realigned valve and will conduct training.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 April 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capbale of closing with an angle of inclination of up to 3.5 degree opposing closure. Fire screen door 03-3-32, 05-2-09, 05-2-04, 05-4-04 would not fully travel to altached position. 74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2025
Resolution: Vessel maintenance team made all required door adjustments to operate correctly upon subsequent inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 31 March 2024 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every life boat shall consist of a food ration totaling not less than 10,000kJ for each person the lifeboat is permitted to accommodate; kept in airtight packaging and be stored in a watertight container. A total of 27 food rations lost their airtight seal. 74 SOLAS 20 III/34 LSA Code 4.4.8.12
Action required: 10 - Deficiency Rectified
Due 31 March 2024
Resolved 31 March 2024
Resolution: Replaced bad food rations.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5deg opposing closure. Fire Doors FD-03-3-32 and FD-06-4-02 are not fully closing. 74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Due 31 March 2024
Resolved 31 March 2024
Resolution: Fire doors fixed to now fully close.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 October 2023 Resolved
ESCAPE DOORS FROM PUBLIC SPACES THAT ARE NORMALLY LATCHED SHALL BE FITTED WITH A MEANS OF QUICK RELEASE. SUCH MEANS SHALL CONSIST OF DOOR-LATCHING MECHANISM INCORPORATING A DEVICE THAT RELEASES THE LATCH UPON THE APPLICATION OF A FORCE IN THE DIRECTION OF ESCAPE FLOW. USCG PSCO OBSERVED 03 TWIST LOCK MECHANISMS IN THE KIDS CLUB'S ESCAPE ROUTES. 74 SOLAS 20 II-2/13.3.2.6.2
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2023
Resolution: Received Master's statement attesting to rectification of twist locks for the Kids Club room onboard (see documents).
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 November 2019 Resolved
The fire penetrations of the divisions shall be maintained at openings and penetrations. B class bulkhead in escape route to lifeboat embarkation on deck 8 has penetation measuring approx. 1/2 sq. foot. 74 SOLAS (14) Ch II-2 Reg 9.1
Action required: 10 - Deficiency Rectified
Due 25 December 2019
Resolved 4 December 2019
Resolution: VSL provided documents with repairs completed and email with approval from DNV GL. Door penetration closed by metal plate and fitted with rock wool.

Ownership record