GREENTEC

GREENTEC is a 2008 freight ship. The Coast Guard has recorded 3 inspections in 2017, along with 4 deficiencies and 1 operational control.

Records in 2017. Most recent: inspection, 22 April 2017.

Built
2008
Last inspected
22 April 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2017
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9493509
1115791
Flag
HONG KONG
Maury page id
psix-1115791

Documentation record

Tonnage as PSIX records it20763 - Convention (Subpart B), Gross Ton
11627 - Convention (Subpart B), Net Ton
33035 - Dead Weight, Metric Ton
41799 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

22 April 2017 COE-Offshore · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6130181
18 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127190
7 February 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6078328

Deficiency record · 4

Fire Fighting › Fixed Fire Detection System › Alarms
Issued 7 February 2017 Resolved
1000 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed that the alarm monitoring system malfunctioned and was unable to display and record active or previous alarms - 74SOLAS(14) I/11(a) - 60a
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2017
Resolved 9 February 2017
Resolution: Received, reviewed and accepted class report from China [name withheld] stating the deficiency was rectified.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 7 February 2017 Resolved
1099 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed that the high pressure oil pipe leakage alarm resevoir was full of oil, with no alarm active or detected. PSCO noted that monthly maintenance had not been conducted on the alarm since November 2016 - 74SOLAS(14)I/11(a) - 60a
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2017
Resolved 9 February 2017
Resolution: Received, reviewed and accepted class report from China [name withheld] stating the deficiency was rectified.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 7 February 2017 Resolved
9900 - The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks must maintain a ballast water management plan that has been developed specifically for the vessel. PSCO noted that the vessel conducts empty-refill ballast water exchanges, but the plan specifies flow-through as the only exchange method - 33CFR151.2050(g) - 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2017
Resolved 22 April 2017
Resolution: Vessel provided ballast water records showing that the vessel now performs "Flow-through method" as per their BW plan.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 7 February 2017 Resolved
9900 - Vessel master/crew must complete visual inspections in accordance with section 4 of the VGP and record all results in the vessel's recordkeeping documentation. The master/crew could not produce documentation that the visual inspections have been conducted or recorded - 33 USC 1251 - VGP Part 4 - 10c
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: The vessel's master was advised of U.S. Environmental Protection Agency's VGP requirements.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.