MAURY USCG vessel records
← All vessels

CLEANTEC

CLEANTEC is a 2009 freight ship. The Coast Guard has recorded 4 inspections since 2016, most recently in March 2020, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2020. Most recent: inspection, 30 March 2020.

Built
2009
Last inspected
30 March 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2020
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9473418
1115792
Flag
HONG KONG
Maury page id
psix-1115792

Documentation record

Tonnage as PSIX records it20763 - Convention (Subpart B), Gross Ton
11627 - Convention (Subpart B), Net Ton
41799 - Displacement, Ton
33270 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

30 March 2020 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6933366
4 May 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6405536
31 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806857
29 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5805867

Deficiency record · 5

Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2018 Resolved
CARGO SPACES ON CARGO SHIPS OF 2000GT AND UPWARDS SHALL BE PROTECTED BY A FIXED CARBON DIOXIDE OR INERT GAS FIRE EXTINGUISHER SYSTEM.../PSC OBSERVED NUMEROUS LOOSE FLEX LINES FOR CARGO SPACES IN CO2 ROOM. 74SOLAS(14)II-2/10.7.1.3
Action required: 10 - Deficiency Rectified
Resolved 4 May 2018
Communications › Radio Communications › EPIRB
Issued 4 May 2018 Resolved
EVERY SHIP PROVIDED WITH AN EPIRB, THE EPIRB SHALL BE CAPABLE OF FLOATING FREE IF THE SHIP SINKS/ HYDROSTATIC RELEASE ON EPIRB WAS EXPIRED. 74SOLAS(14) IV/7.1.6.6.4
Action required: 10 - Deficiency Rectified
Resolved 1 April 2020
Resolution: Replaced hydrostatic release with new release.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 4 May 2018 Resolved
A LINE THROWING APPLIANCE CONPLYING W/ THE REQUIREMENTS OF SECTION 7.1 OF THE CODE SHALL BE PROVIDED/ ALL LINE THROWING APPLIANCES WERE EXPIRED. 74SOLAS(14)III/18
Action required: 10 - Deficiency Rectified
Resolved 1 April 2020
Resolution: Four new line throwing devices were on board.
Lifesaving › Hand Flares › Expired
Issued 4 May 2018 Resolved
EACH SURVIVAL CRAFT SHALL BE FULLY EQUIPED AS REQUIRED BY THIS CHAPTER AND THE CODE. TWO HAND FLARES WERE EXPIRED. 74SOLAS(14)III/13.1.4 LSA 4.8.8.14
Action required: 10 - Deficiency Rectified
Resolved 1 April 2020
Resolution: New hand flares were on board.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 May 2018 Resolved
CYLINDERS MUST ALWAYS BE SECURED AND WHEN NOT IN USE, THEY MUST BE STOWED WITH VALVE PROTECTION CAP IN PLACE. NUMEROUS CYLINDERS WERE OBSERVED W/OUT CAPS. 46CFR147.60(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2020
Resolution: Vessel provided pictures of all cylinders capped.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.