MAURY USCG vessel records
← All vessels

AMFITRITI

AMFITRITI is a 2008 tank ship. The Coast Guard has recorded 4 inspections since 2019, most recently in July 2021, along with 1 deficiency and 1 operational control.

Records from 2019 to 2021. Most recent: inspection, 1 July 2021.

Built
2008
Last inspected
1 July 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 July 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2019–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9419369
1115844
Flag
LIBERIA
Maury page id
psix-1115844

Documentation record

Tonnage as PSIX records it62782 - Convention (Subpart B), Gross Ton
35791 - Convention (Subpart B), Net Ton
132025 - Displacement, Ton
112990 - Dead Weight, Ton
62782 - Regulatory (Subpart C or D), Gross Ton
35791 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

1 July 2021 COC-TVE Renew · PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7241535
19 March 2020 COE-Dockside · PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6928178
15 March 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6926920
19 January 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6612477

Deficiency record · 1

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2019 Resolved
Every steam pipe and every fitting connected there through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. Steam pipe at the lower connection of the cascade tank is leakeing excessively, causing an excess of condensate water to build up behind the insulation and the tank. 74SOLAS(04) Ch. II-1, Reg.33.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 January 2019
Resolved 19 March 2020
Resolution: Received repair report from vessel's master and visually verified repair was complete.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.