Records from 2000 to 2001. Most recent: inspection, 29 August 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 29 August 2001
Resolved
ON BOTH 58 PERSON LIFEBOATS PROVE PROPER OPERATION OF LOWERING AND RECOVERING EQUIPMENT.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Lifesaving
Issued 29 August 2001
Resolved
HANDLE THAT WAS DAMAGED IN RECENT PERSONNEL EQUIPMENT ACCIDENT WITH LIFEBOAT NR. 2 IS NOT TO LEAVE RIG WITHOUT APPROVAL OF CG OCMI.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Lifesaving
Issued 29 August 2001
Resolved
CG OCMI IS TO BE NOTIFIED PRIOR TO BRAKE DISASSEMBLY ON LIFEBOAT NR. 2.
Condition: Unknown
Due 12 September 2001
Resolved 12 September 2001
Electrical
Issued 19 July 2001
Resolved
Remove temporary installation for washing machine in laundry room.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Construction/Loadline
Issued 19 July 2001
Resolved
Crop and renew wasted bulkhead above door to change room.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Construction/Loadline
Issued 19 July 2001
Resolved
Provide Class Society report attesting to satisfactory water tight integrity of all main deck water tight doors and hatches.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Construction/Loadline
Issued 19 July 2001
Resolved
Provide dogging wrenches for all water tight doors.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Fire Fighting
Issued 19 July 2001
Resolved
Replace or provide servicing report for fire extinguishers number 72 and 73.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Unknown
Issued 19 July 2001
Resolved
Provide documentation or replace pressure relief valve for drill floor pressure vessel.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Lifesaving
Issued 19 July 2001
Resolved
Provide third party survey report/class report for shell damage of number two lifeboat.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Lifesaving
Issued 19 July 2001
Resolved
Repair foward limit switch on number three lifeboat.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Accommodation/Occupational Safety
Issued 19 July 2001
Resolved
Crop and renew vent ilation duct for galley vent on foward side of house.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Electrical
Issued 19 July 2001
Resolved
Label all exterior emergency shutdowns.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Construction/Loadline
Issued 19 July 2001
Resolved
Repair number two bilge pump.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Electrical
Issued 19 July 2001
Resolved
Prove proper operation of emergency generator overspeed trip.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Electrical
Issued 19 July 2001
Resolved
Prove proper operation of number one generator reverse power relay.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Electrical
Issued 19 July 2001
Resolved
Mount all recepticles for luandry equipment.
Condition: Unknown
Due 21 August 2001
Resolved 24 September 2001
Construction/Loadline
Issued 31 July 2000
Resolved
RENEW SOUNDING CAPS 4 EACH IN ENGINE ROOM.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
REPAIR HANDLE ON EYE WASH STATION IN SACK ROOM.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Construction/Loadline
Issued 31 July 2000
Resolved
MAKE REPAIRS TO BILGE PIPING MANIFOLD WHERE SOFT PATCHED, CROP AND RENEW TOGOOD STEEL.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Engineering
Issued 31 July 2000
Resolved
INSTALL FRAME SCREEN ON LUBE OIL TANK IN ENGINE ROOM.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 31 July 2000
Resolved
ALL DEAD END WIRES TO BE REMOVED OR TERMINATED IN A METAL JUNCTION BOX.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Engineering
Issued 31 July 2000
Resolved
PROVIDE DOCUMENTATION AS TO THE STATUS OF THE AUX BOILER.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 31 July 2000
Resolved
RENEW CONTROL TUBING FOR HALON SYSTEM.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 31 July 2000
Resolved
PROVE PROPER OPERATION OF # 1 SSG.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 31 July 2000
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY ON # 3 SSG.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 31 July 2000
Resolved
PROVE PROPER OPERATION OF OVERSPEED ON # 2 SSG.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 31 July 2000
Resolved
REMOVE 55 GAL. DRUMS IN AREA OF HALLON BOTTLE BANK.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
PROVE PROPER OPERATION OF MUD PIT PURGE ALARM AT DRILL FLOOR.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Documentation
Issued 31 July 2000
Resolved
PROVIDE ABS APPROVED OPERATIONS MANUAL AND CONSTRUCTION PORIFOLIO.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
PROVIDE PROOF OF 6 QUALIFIED LIFEBOATMEN.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
OPERATIONALLY TEST ALL LIFEBOATS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
PROVIDE DOCUMENTATION ATTESTING TO LOAD TEST OF LIFEBOAT AND LIFERAFT DAVITS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
CHANGE FUEL OIL ON LIFEBOATS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
MOUNT ALL LIFEBUOYS
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
PLACE LIFEJACKETS IN PROPER LOCATIONS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 31 July 2000
Resolved
LABEL FIRE EXTINGUISHERS
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 31 July 2000
Resolved
PLACE FLASHLIGHTS WITH FIREMAN'S OUTFITS
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Accommodation/Occupational Safety
Issued 31 July 2000
Resolved
PROPERLY RESTOCK HOSPITAL SPACE.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Documentation
Issued 31 July 2000
Resolved
PROVIDE DOCUMENTATION OF AFT CRANE LOAD TEST BY ABS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
CONDUCT FIRE AND BOAT DRILL
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Deck/Cargo
Issued 31 July 2000
Resolved
PROVIDE HAND SIGNAL CHART FOR CRANES
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Accommodation/Occupational Safety
Issued 31 July 2000
Resolved
CROP AND RENEW WASTED HANDRAILS: (1) MAIN DECK, PORT SIDE BOTTOM RAIL (2) PORT SIDE LEADING TO HELIPORT, TOP RAIL AND MIDDLE RAIL.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 31 July 2000
Resolved
TEST EMERGENCY LIGHTS IN ACCOMODATIONS.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 31 July 2000
Resolved
REPAIR DOOR TO HALON RELEASE STATION LOCKER FOR RADIO ROOM
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 31 July 2000
Resolved
PLACE EYE WASH AND SHOWER STATIONS ON LOCATION.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Accommodation/Occupational Safety
Issued 31 July 2000
Resolved
LEVEL 3 TOILET / SHOWER ROOM - REPAIR MIDDLE TOILET AND REPLACE SHOWER HANDLE ON RIGHT SHOWER.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Documentation
Issued 31 July 2000
Resolved
PROVIDE ABS APPROVED FIRE CONTROL AND HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Electrical
Issued 31 July 2000
Resolved
PLACE 12 FEET OF DIELECTRIC MAT IN AREA OF CONTROL ROOM SWITCH BOARD.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000