Records from 2016 to 2026. Most recent: inspection, 5 February 2026.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
5 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304088
20 February 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082493
3 February 2025
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074099
11 December 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837709
25 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7752280
9 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631806
17 January 2023
Hull Examination · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7621216
27 January 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386687
18 March 2021
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7158606
21 January 2021
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128559
13 February 2020
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6906818
27 January 2020
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6899894
31 January 2019
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6618656
23 October 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570690
10 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6384293
18 January 2018
Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6338462
9 February 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6083375
24 May 2016
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5882143
18 February 2016
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5845344
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 February 2025
Resolved
(a) Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had 6 red hand held flares on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 8 April 2025
Resolution: Verified distress signals replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 March 2022
Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate of Documentation for that vessel in accordance with 67.163.Vessel's COD is expired and may not operate with passengers. Vessel can operate 6 or less passengers for hire provided the vessel has proper state documentation, and the requirements of 46 CFR 176.114 shall apply. Equipment required by the certificate of inspection shall not be removed or altered without the permission of the cognizant officer in charge marine inspection (OCMI).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: Vessel has valid COD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021
Resolved
Fwd fire extinguisher bracket was corroded and broken. Replace bracket to satisfaction of MI
46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2021
Resolution: Attended call out for def, installed new bracket to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 March 2021
Resolved
Vessel did not have ventillation covers for machinery space. O/O indicated that covers had been ordered but not yet recieved. Vessels can not cut off air flow to machinery space without covers.
46 CFR 181.420(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2021
Resolution: Vessel had new ventillation covers fabricated to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2021
Resolved
Port side fuel shutoff valve would not operate in both directions. Valve could be manually closed from operating station but could not be returned to open position. Replace cable to ensure both directional operations.
46 CFR 182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 14 April 2021
Resolution: Vessel submitted objective evidence clearing deficiency to satisfaction of MI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 February 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
Resolution: Acquired all Publications
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 February 2020
Resolved
Up to date charts not onboard the vessel. Need up to date charts prior to passenger carriage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2020
Resolution: Acquired updated charts
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 18 January 2018
Resolved
Replace/lubricate and clean engine suction valve. Conduct test to ensure full open and closing of valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2018
Resolved 30 January 2018
Resolution: Vessel conducted satisfactory test.
Stability › Weathertight Integrity › General
Issued 18 January 2018
Resolved
Replace missing hatch securing latches
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2018
Resolved 30 January 2018
Resolution: Vessel replaced latches
Construction/Loadline › Penetrations › Valve Flange
Issued 18 January 2018
Resolved
Remove strainer from fwd valve and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2018
Resolved 30 January 2018
Resolution: Vessel conducted satisfactory test of valve.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 24 May 2016
Resolved
Provide fire detection system service report
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 28 June 2016
Resolution: Vessel provided valid report
Lifesaving › Lifebuoys › Stowage
Issued 24 May 2016
Resolved
Install ringbuoy light mounting bracket
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 25 May 2016
Resolution: Vessel provided mounting bracket
Lifesaving › Hand Flares › Quantity
Issued 24 May 2016
Resolved
Provide one approved distress signal
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 25 May 2016
Resolution: Vessel provided flare
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 May 2016
Resolved
Replace / repair fwd fire extinguisher mounting bracket
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 25 May 2016
Resolution: Vessel repaired bracket
Engineering › Bilge Water Management System › Interface Detector
Issued 24 May 2016
Resolved
Replace engineroom bilge audible alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 25 May 2016
Resolution: Vessel replaced alarm
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 18 February 2016
Resolved
Replace fwd fire extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2016
Resolved 28 March 2016
Resolution: Vessel replaced extinguisher
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 February 2016
Resolved
Replace ring buoy line
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2016
Resolved 28 March 2016
Resolution: Vessel replaced buoy