Records from 2001 to 2026. Most recent: inspection, 2 January 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 January 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation;Be suitable for route and service; and Have suitable propulsion controls to provide the operator full control at each operating station. Vsl suffered a loss of full steering and flanking capabilities. Repair or replace damaged components to original. Conduct test of the system and to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 9 February 2026
Resolution: Conducted a satisfactory inspection and test of the vessels steering and propulsion systems.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 September 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Vessel was found to have extension cords wired in tandem with immersion pump electrical cables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2025
Resolved 14 October 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 September 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space...
Vessel needs to upgrade emergency lighting. Lighting did not cover sufficient spaces. Phosphorescent strips (if used) need to be added to ladder wells, door over heads and egress points.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2025
Resolved 14 October 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
Vessel was found to have excessive oily waste accumulation in the bilges of the E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2025
Resolved 14 October 2025
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 22 September 2025
Resolved
Plastic pipe and associated fittings must be approved to approval series 164.141 as follows:(i) All piping, except pipe used on open decks, in cofferdams, void spaces, or ducts, must meet the flame spread requirements of Appendix 3 of IMO Resolution A.753(18).
Action required: 705 - Other - as specified
Due 30 June 2027
Resolved 14 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 September 2025
No resolution recorded
c)The valve must be installed in the fuel piping directly outside of the fuel oil supply tank.
(e)Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it.
Vessels fuel oil shut off valves were located in line with each engines filters and not closest to the supply tank as possible. Relocate all 03 shut off valves as closest to the supply tanks as possible. Label the remote actuating staitons appropriately.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 September 2024
Resolved
Each towing vessel must perform the tests in Table 143.245(b). There is no record of any of the tests in the table. Complete all of the tests and record IAW 143.245(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 20 September 2024
Resolution: Submitted the twice in five alarms. In documents.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 20 September 2024
Resolved
Crew members must be familiar with their firefighting duties, and, specifically how to fight a fire in the engine room and else whee onboard the towing vessel. Crew members did not know their duties during an engine room fire. Provide proof that crew members have conducted drills and is recorded in accordance with 46CF140.420(g).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 18 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 September 2024
Resolved
Charts, including electronic charts acceptable to the Coast Guard, of appropriate scale to make safe navigation possible. Vessel has Coastal Explorer version of rose point which is for pleasure boaters. Vessel is required commercial grade Rose Point with a Letter of Conformance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 18 October 2024
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 September 2024
Resolved
The emergency duties and duty stations required must be posted at each operating station and in a conspicuous location in a space commonly visited by crew members. If posting is impractical, they may be kept onboard in a location readily available to the crew. There was no emergency duty stations posted on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 18 October 2024
Resolution: Posted station bill for the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists. Alarms must be provided for bilge alarms. There were no visual or audible bilge alarms for the vessel.
46CFR143.230
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2023
Resolution: Audible and visual alarm repaired. test complete in the presence of an MI, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2023
Resolved
All hand portable fire extinguishers onboard the vessel, must be inspected or tested at least once every 12 months. Fire extinguisher in the bottom deck crew berthing was not serviced with the other fire fighting equipment onboard.
46CFR142.240
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2023
Resolved
Each towing vessel must have a fire detection system installed to detect engine room fires. Each detector must be installed, tested and maintained in accordance with the manufacturers design. Fire/heat detector in the engine room was loose/broken.
46CFR142.330
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
Resolution: heat detector re-mounted and tested, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 September 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency conditionexists. An alarm must be provided for the low hydraulic steering fluid. Vessel did not have a low level alarm on their hydraulic tank.
46CFR143.230
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 18 September 2023
Resolution: low steering fluid alarm installed. Test completed in the presence of an MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 September 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Hydraulic steering lines for primary and flanking rudders found worn and cracked, replace affected lines to factory and to the satisfaction of the Marine inspector.
46CFR143.205
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 19 September 2023
Resolution: New hyd. steering lines replaced. steering tested for leaks, all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 September 2023
Resolved
The VHF–FM radio must be installed at each operating station and connected to a functioning battery backup.
Radio was was not connected to battery back up.
46 CFR 140.715(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2023
Resolution: Emergency back up batteries replaced and to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
MDE electrical box has multiple zip ties securing it.
46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 18 September 2023
Resolution: Electrical box re-mounted all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
Switchbox missing hardware on cover. "Off" button missing on face of panel.
46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 18 September 2023
Resolution: Cover plugged preventing shock hazard, all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
Port side overhead juction box face plate needs to be replaced.
46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 18 September 2023
Resolution: Junction box cover replaced, all sat.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 22 June 2022
Resolved
High bilge level alarm must be visual and audible at the operating station. The bilge alarm on vessel does not have a visual indicator at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 19 July 2022
Resolution: Operator installed visual indicator for alarm on bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2022
Resolved
Propulsion machinery must be maintained to ensure proper operation. The fuel delivery line between primary and secondary fuel filter on the starboard main engine is severely chaffed, replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 19 July 2022
Resolution: Fuel line replaced with chaffing gear added.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2022
Resolved
The Employee Assistance Program (EAP) must include display and distribution of community service hot-line telephone number for crewmember assistance. There is currently no EAP hot line numbers displayed on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 19 July 2022
Resolution: EAP poster posted in the galley.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 June 2022
Resolved
Means must be provided for closing each doorway, ventilator and annular space around funnels and other openings into the machinery space. The machinery space ventilation closure is bent and stuck open, rendering it inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 19 July 2022
Resolution: Ventilation closure repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2022
Resolved
A fixed fire pump must be capable of delivering water of at least 50psi and flow rate of at least 80 gpm. There was debris in the fire starboard fire hose which made the fire nozzle inoperable with no pressure. Crew removed debris and showed good pressure from starboard hose.
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Crew removed debris from hose and showed good pressure from fire pump.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 June 2022
Resolved
Each fire drill must, as far as practicable, be conducted as if there was an actual emergency. When conducting fire drill during inspection, crewmembers were unfamiliar with basic shipboard procedures for a galley fire. Training was completed with crew.
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Completed training with crew and master on shipboard fire fighting procedures.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 June 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas and can be automatic, battery powered lights with duration of no less than 2 hours OR non electric phosphorescent adhesive lighting strips installed along escape routes. There is currently no emergency lighting or phosphorescent strips in accommodation spaces for egress routes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 19 July 2022
Resolution: Illumiscent strips installed in all egress points for accomodation spaces.