MAURY USCG vessel records
← All vessels

MAERSK CAP JACKSON

MAERSK CAP JACKSON is a 2010 freight ship. The Coast Guard has recorded 28 inspections since 2016, most recently in July 2026, along with 9 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 11 July 2026.

Built
2010
Last inspected
11 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 July 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9484560
9V2249
1116397
Flag
SINGAPORE
Maury page id
psix-1116397

Documentation record

Tonnage as PSIX records it47877 - Convention (Subpart B), Gross Ton
59337 - Dead Weight, Metric Ton
76927 - Displacement, Metric Ton
29554 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

11 July 2026 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8437029
28 October 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8025739
24 October 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8019470
23 October 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8023890
2 February 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631663
30 January 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7630973
21 September 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7563492
15 December 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7368533
16 July 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7007367
17 November 2019 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 6858073
23 August 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6792439
6 June 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6703286
3 August 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6500052
20 July 2018 PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6485379
10 May 2018 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6406077
7 May 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6408045
5 May 2018 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6406385
28 February 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6363718
18 February 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6357384
4 December 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6318215
20 September 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6270413
6 July 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6195847
28 June 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6189995
16 November 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6041873
7 September 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5996703
22 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5980292
16 June 2016 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5906214
10 June 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5903167

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2018 Resolved
74SOLAS(14)II-2/4.1.1 60ac PURPOSE OF THIS REGULATION IS TO PREVENT IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED CONSTANT FUEL LEAK FROM M/E CYL 3, 4, 6.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2018
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2018 Resolved
74SOLAS(14)II-2/4.1.1 60ac PURPOSE OF THIS REGULATION IS TO PREVENT IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAK FROM MAIN ENGINE HIGH PRESSURE PUMP NUMBER 3.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2018
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2018 Resolved
74SOLAS(14)II-2/4.1.4 60ac PURPOSE OF THIS REGULATION IS TO PREVENT IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: IGNITION SOURCES SHALL BE RESTRICTED. PSCO OBSERVED EXCESSIVE FUEL OIL IN BILGE.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2018
Resolution: Received satisfactory class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 20 July 2018 Resolved
74SOLAS(14)II-2/4.1.3 60ac PURPOSE OF THIS REGULATION IS TO PREVENT IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: IGNITABLILITY OF COMBUSTIBLE MATERIALS SHALL BE RESTRICTED. PSCO OBSERVED OIL SOAKED LAGGING AROUND MAIN ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2018
Resolution: Received satisfactory class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2018 Resolved
74SOLAS(14)I/11(b) 50ac AFTER SURVEY OF SHIP UNDER REGS 7,8,9,10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY SURVEY, W/O SANCTION OF ADMIN. PSCO DISCOVERED HOSE LAYING IN BILGE. WHEN ASKED, [name withheld] WAS BEING USED FOR XFERS OF WASTE OIL FROM BILGE WELL TO SLUDGE TK OUTSIDE CLASS APPROVAL FOR SYSTEM.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2018
Resolved 21 July 2018
Resolution: Received satisfactory class report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 July 2018 Resolved
ILL 1/8 40ac RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON DARK GROUND. PSCO OBSERVED CLASS ABBREVIATION ON LOAD LINE WAS NOT CORRECTLY CONTRASTED.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2018
Resolution: Cless sent report stating that load lines had been repainted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 July 2018 Resolved
74SOLAS(14)II-2/4.2.2.3.5.2.2 10ac OIL-LEVEL GAUGES MAY BE USED IN PLACE OF SOUNDING PIPES SUBJ TO FOLLOWING: IN CARGO SHIPS, FAILURE OF SUCH GAUGES OR OVERFILLING OF TANK SHALL NOT PERMIT RELEASE OF FUEL INTO SPACE. PSCO OBSERVED SIGHT GLASS HOLD BACKS ON OIL TANK.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 20 July 2018
Resolution: SHIP'S CREW REMOVED HOLD BACKS FROM SIGHT GLASSES.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 June 2016 Resolved
1430- Auxlliary Engines- Each emergency generating set arranged to be automatically started shall be equiped with starting devices. Gen set is uncapable to start in emergency mode due to dead batteries 74 Solas(09) 11-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2016
Resolution: Received class report attesting to the replacement of the emergency generator battery and successful starting of the generator.
Construction/Loadline › Markings › Load Line Mark
Issued 16 June 2016 Resolved
1220- Freeboard marks- The ring lines and letters shall be painted in white or yellow on a dark ground in black on a light ground. The lines shall be plainly visible. Deck line and load lines are not clearly marked and visible. ICLL Reg 8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 August 2016
Resolution: Recieved pictures showing load line reapainted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.