NORWEGIAN GETAWAY is a 2014 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in April 2026, along with 9 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 17 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it145655 - Convention (Subpart B), Gross Ton 132549 - Convention (Subpart B), Net Ton 145655 - Simplified, Gross Ton 16959 - Dead Weight, Metric Ton 69236 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2023Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the d irection of escape flow. 02 twist lock mechanisms were fitted in means of escape for the Humidor
and Entourage Lounge.
74 SOLAS 20 11-2/13.3.2.6.2 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2023
Resolved 6 November 2023
Resolution: Received classification society attesting to the rectification of the removal of the found twist lock mechanisms (see documents).
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 November 2023Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing. PSCO found 04 fire doors (15-6-015, 15-2-10, 15-01-01 , 08-06-002) that did not close in accordance to its construction standards.
74 SOLAS 20 11-2/9.4.1.1.5.1 10c
Action required: 10 - Deficiency Rectified
Resolved 4 November 2023
Resolution: Vessel's carpenter rectified the deficient doors.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2023Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: means of escape systems and appliances. PSCO found that the freezer entrapment alarm in "Sky Ice Bar" was frozen and not operable.
SOLAS 20 11-2/14.2.1.1.3 10c
Action required: 10 - Deficiency Rectified
Resolved 4 November 2023
Resolution: Crew defrosted the detection area. CG witnessed satisfactory test of detection.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 June 2023Resolved
04110 - Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Two stairwell guides in the aft stairwell on Deck 6 were not familiar with assembly station locations and emergency evacuation procedures. 74 solas (20) III/19.2.1 - 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 June 2023
Resolved 3 June 2023
Resolution: Crew members were identified and removed from their emergency duty stations to re-train on procedures and knowledge for abandon ship.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2021Resolved
The sauna door shall open outwards by pushing. Door to sauna in The Haven does not open outwards. SOLAS 04 II-2/9.2.2.3.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2022
Resolved 4 January 2022
Resolution: DNV Survey report confirming the sauna door now opens outwards.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 December 2021Resolved
Detection and alarm for manual operated calls points shall be placed effectively to ensure a readily accessible means of notification. Several manual call points on deck 15 and 16 did not operate. SOLAS 04 II-2/7
Action required: 10 - Deficiency Rectified
Resolved 22 December 2021
Resolution: Crew found that the call point boxes were not making necessary contact to signal an alarm. Crew replaced defective boxes and retested with PSCO's, all SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 December 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Panic alarm in the sauna in The Haven did not notify the reception desk. SOLAS 20 I/11
Action required: 10 - Deficiency Rectified
Resolved 22 December 2021
Resolution: Crew reset the system, and conducted test with the PSCO's present. Spa manager received alarm notification, and responded to the alarm.
Engineering › Electric Propulsion System › Transformer Circuitry
Issued 26 March 2017Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. Vessel starboard pod suffered a reduction in power and is currently operating at 50% capacity. 74 SOLAS(14 CONS) I/11(a)
Action required: 705 - Other - as specified
Resolved 29 October 2017
Resolution: Received Calss report attesting to proper correction of deficiency.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 17 January 2016Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The high fog line found on deck 15 Spa area was found ruptured, leaking large amounts of water. 74SOLAS(14) CH. II-2/14.1.1
Action required: 705 - Other - as specified
Resolved 17 January 2016
Resolution: Rectified on the spot and verified by USCG.