← All vessels
PHOENIX ADMIRAL
PHOENIX ADMIRAL is a 2011 tank ship. The Coast Guard has recorded 21 inspections since 2017, most recently in June 2026, along with 9 deficiencies and 2 operational controls.
Records from 2017 to 2026. Most recent: inspection, 15 June 2026.
- Built
- 2011
- Last inspected
- 15 June 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9482603
9V8776
1116514
Flag
SINGAPORE
Maury page id
psix-1116514
Inspections, by type
…with no type recorded2
Years with a record
10 calendar years (2017–2026)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it62234 - Convention (Subpart B), Gross Ton
34915 - Convention (Subpart B), Net Ton
62234 - Regulatory (Subpart C or D), Gross Ton
34915 - Regulatory (Subpart C or D), Net Ton
114024 - Dead Weight, Metric Ton
134045 - Displacement, Metric Ton
34915 - Convention (Subpart B), Net Ton
62234 - Regulatory (Subpart C or D), Gross Ton
34915 - Regulatory (Subpart C or D), Net Ton
114024 - Dead Weight, Metric Ton
134045 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 21
15 June 2026
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8405103
21 October 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8256462
10 October 2025
PSC B · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8249527
22 October 2024
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022693
14 April 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7894866
15 October 2023
PSC B · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7808617
28 June 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7725775
12 October 2022
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7575798
22 October 2021
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7337542
14 April 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7174962
24 October 2020
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7083045
3 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6966948
14 July 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6746451
2 December 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6585034
19 July 2018
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482115
1 July 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6462739
1 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7044818
9 November 2017
COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6297471
8 August 2017
COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6219485
7 July 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201216
3 July 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6195472
Deficiency record · 9
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 October 2025
Resolved
Every steam pipe and every fitting comected thereto tt-lough which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed leaking steam pipe in lower engine room overhead.
74SOLAS II-1/33.1
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 10 October 2025
Resolved
Secondary means of allowing full flow relief of vapor...Pressure sensors may be fitted in each tank. Such monitoring equipment shall also provide an alarm facility which is activated by detection of over-pressure or under-pressure conditions within a tank. PSCO observed malfunctioning pressure sensor for number 5 stbd cargo tank.
74 SOLAS (20) II-2/11.6.3.2
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 10 October 2025
Resolved
The ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a soft patch on the #2 ballast water drain line in the pumproom. PSCO also observed excessive leak on the #1 ballast pump packing.
74 SOLAS(20) I/11(a)
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 April 2024
Resolved
All ships 300 GT and above engaged on international voyages, shall be fitted with an automatic identification system(AIS) that shall provide automatically to various shore stations, other ships, including the ship;s identity, type, position, course, speed, navigational status, and other safety-related information. Vessel's AIS was identified to be broadcasting intermittently during transit to berth. - 74SOLAS (20) V/19.2.4.5.1 - 17(c)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022
Resolved
The height of bulwarks or guard rails shall be at least 1 meter. Areas of guard rail replaced by chain do not meet the requirements. ICLL Reg 25(2)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 October 2022
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Hyper mist nozzles found to be partialy obstructed by plastic in purifier room and over generators. 74SOLAS (20 CONS) II-2/14.2.1.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 24 October 2020
Resolved
High level alarms must be visible and audible so that it can be seen and herad on vessel where cargo is controlled. HIgh level alarm cannot be seen/heard on deck. Def to be repaired prior to loading cargo.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2018
Resolved
001 - 7110 - Isloation valves shall be provided in the foam main, and the fire main when this is an integral part of the deck foam system immediately forward of any monitor position to isolate damaged sections of those mains. PSCO observed number 2 isolation valve for foam monitors inoperative. SOLAS 74 AM 14/10.8.1 FSS CODE 14/2.3.4 40a
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 19 July 2018
Resolved
002 - 6106 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects shall remain fit to proceed to sea without danger to the ship or persons on board. PSCO could not witness test of cargo pumps due. Chief officer did not want to run due to no cargo. Vessel restricted from discharging cargo in united states until cargo pumps are tested. SOLAS 74 AM I/11 40c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.