Records from 2013 to 2025. Most recent: inspection, 10 October 2025.
Inspection history · 23
10 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250536
13 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8047280
21 November 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8027744
7 August 2023
Damage Survey · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7762701
3 August 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7762160
3 August 2022
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7517600
11 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7343753
19 August 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7270825
9 February 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7129212
23 September 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7056287
29 January 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6898847
10 January 2020
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6885850
7 January 2020
Administrative Inspection · Plan Review "T" Boat · Simplified Stability Test · Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6910840
13 May 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6682756
2 May 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6674219
20 June 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6450686
13 June 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6440619
9 May 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138726
20 April 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6125971
9 June 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5902379
8 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5901047
23 May 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5884055
4 May 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5862125
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 November 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 46 CFR 80.59 once every five years.
Vessel's Communications Act Safety Radiotelephony Certificate does not include the vessel's EPIRB (box not checked) as being verified during the issuance of the certificate (OCT 2025).
46 CFR 184.502
47 CFR 80.93
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 21 November 2025
Resolution: Received emailed copy of re-issued FCC Radiotelephony certificate that included verification of EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Repair to the satisfaction of the U.S. Coast Guard.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2024
Resolution: Received video of affected machinery satisfactory repaired and operating.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 November 2024
Resolved
Vessel must comply with applicable requirements set forth in 47 CFR part 80.
FCC Safety Certificate was not onboard and the master did not have an FCC operators permit.
46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 21 November 2024
Resolution: FCC documents were provided, SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2024
Resolved
Each item of lifesaving equipment must be in serviceable condition.
04 life jackets require new retro reflective tape. Passenger count is reduced to 126 until this is corrected.
46 CFR 176.808
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2024
Resolved 27 November 2024
Resolution: 04 life jackets were onboard and marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2024
Resolved
At each inspection all machinery to include generators shall be inspected.
Both generators had loose belts allowing contact with the machinery guards. Properly tension generator belts to the satisfaction of the Coast Guard.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 27 November 2024
Resolution: Generator belts were replaced and properly tensioned, SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2023
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for COI annual inspection on 23FEB23 and has yet to receive a COI inspection.
Vessel shall not operate with passengers until annual has been completed.
46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2023
Resolved 21 November 2024
Resolution: Completed Inspection, issued COI.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 January 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB.
EPIRB registration is expired. Vessel is limited to Lakes, Bays and Sounds until EPIRB is registered.
46 CFR 180.64
Action required: 705 - Other - as specified
Due 11 January 2022
Resolved 18 January 2022
Resolution: Vessel registered EPIRB.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 19 August 2021
Resolved
MSD shall comply with 33 CFR Part 159.
MSD found overflowing and leaking in forward internal space. Make repairs or replace MSD with larger MSD. MSD to accommodate passengers.
46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2021
Resolved 24 August 2021
Resolution: Vsl rep removed MSD from holding tank and created waste management plan to pump the tanks before starting the day of operations.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 August 2021
Resolved
Crew members shall be trained for emergency situations onboard.
During fire drill, deckhand was unfamiliar with fire isolation valve above pump.
46 CFR 185.420
Action required: 10 - Deficiency Rectified
Resolved 19 August 2021
Resolution: Master provided training to the crew during inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 February 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. It is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. There was no proof on board to show that the EPIRB was registered with NOAA. Provide proof to USCG. Vessel is limited to operations within three nautical miles of land within COI route until rectified.
46 CFR 184.502
47 CFR 80.1061(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2021
Resolved 12 February 2021
Resolution: Owner emailed registration form for EPIRB. EPIRB is not expired and matches info in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Each ring buoy on a vessel must be approved with 160.050 in sub-chapter Q of this chapter. Both ring buoy grab-lines are deteriorated and not serviceable.
46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2019
Resolved 16 May 2019
Resolution: both ring buoys were replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2019
Resolved
provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. An opening within the ventilation duct has free communication between the engine room and #3 compartment.
46CFR182.465(h)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2019
Resolved 16 May 2019
Resolution: Both ventilation duct interior holes were sealed with plywood.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). The electric bilge pump in compartment #4 is inoperable. The hand operated bilge pumps hose does not reach the weather-deck.
46CFR182.520
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 16 May 2019
Resolution: Bilge pump was replaced with new. Hand operated bilge pump hose was extended and demonstrated to marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 May 2019
Resolved
The operator must get vessel underway and conduct drills as required. Vessel has not conducted fire and abandon ship drills as required by OCMI.
46CFR176.404
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2019
Resolved 29 July 2019
Resolution: Witnessed man overboard drill; executed satisfactorily. Reviewed fire drill procedure satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 13 May 2019
Resolved
Where flexible non-metallic hose is permitted for use in piping systems by this section, it must meed SAE J-1942 or be specifically approved by the commandant. Vessel has a short length of fuel hose of unknown approval on both main engines.
46CFR182.720(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 23 May 2019
Resolution: MI was able to cooreleate small length of flexible hose without approval number to fuel hose used on filter assembly to confirm its legitamacy.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 May 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at engine end of the fuel line to stop the fuel flow when servicing accessories. Vessel has no shutoff valve on the engine end of the fuel line.
46CFR182.455(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 23 May 2019
Resolution: MI determined that the fuel shut off on the racor satifies the intent of the regulation, allowing servicing of the accessories (filter).
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 13 May 2019
Resolved
The operator must secure each type I or II device in a manner which prevents discharge of treated or untreated sewage. Vessel does not have a means to secure sanitation device.
33CFR159.7(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 23 May 2019
Resolution: Operator removed handle from overboard valve
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2019
Resolved
A vessel must carry either a first-aid kit approved under series 160.041 or a kit with equivalent contents and instructions. Vessels first aid kit has multiple expired products.
46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 23 May 2019
Resolution: operator procured new first aid kit
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 May 2019
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Belt guards on the port main engine, and both generators
were both removed.
46CFR960
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator re-installed belt guards on both generators and port engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019
Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories (UL) as UL Boat or UL Marine cable. Vessel has a portable extension going from electrical closet to operators station, used as permanent wiring.
46CFR183.340(d)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator removed power strip and extention cord.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2019
Resolved
each vessel must be equipped with at least 2 operable portable battery lights. One of these lights must be located at the operating station. Vessel did not have a portable light at the operating station.
46CFR183.430
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator installed new portable light at operator station.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated on the vessel's security letter, the maximum number of passengers allowed on an upper deck must be indicated by durable markings of at lease 25 millimeters. Vessel has decals printed, but not yet installed.
46CFR185.602(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator installed decals indicating the maximum number of passengers on each deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2019
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Vessel has decals printed, but not yet installed.
46CFR185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator installed decals indicating life jacket stowage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2019
Resolved
On a vessel of not more than 65 feet carrying more than 49 passengers the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi. Vessels gauge is not operable, pressure could not be verified.
46CFR181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: After discussion with CID, the firepump pressure has been determined to be adequate. Future inspectors should pay close attention to ensure the pump does not have any further degregation in pressure.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2019
Resolved
Spanner wrenches must be provided where a 1.5 in ch diameter firehose is required. Vessel does not have a spanner wrench onboard.
46CFR181.310(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator procured a spanner wrench
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2019
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices. Vessel did not have captive chains installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator re-installed all captive chains on hatch covers
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate up-to-date: charts of a large enough scale to make safe navigation possible. Vessel did not have updated charts on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator procured new charts.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 13 May 2019
Resolved
The stability letter must be posted under glass or other suitable transparent material such that all pages are visible. Vessels stability letter was not posted.
46CFR176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
Resolution: operator posted stability letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 May 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel has 02 holes in the weatherdeck deck above compartment #3 that were not documented or approved by the coast guard. Submit repair proposal or provide evidence of Coast Guard approval to satisfaction of marine inspector.
46CFR176.700
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 16 May 2019
Resolution: Both natual ventilation holes in weatherdeck were repaired to origional.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 13 June 2018
Resolved
PRE-ENGINEERED FIXED GAS FIRE EXTINGUISHING SYSTEMS MUST HAVE A LIGHT TO INDICATE DISCHARGE AND AUDIBLE ALARM THAT SOUNDS UPON DISCHARGE AT THE OPERATING STATION. (46CFR181.420)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2018
Resolved 20 June 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 May 2017
Resolved
Vessel's watertight bulkheads are not completely sealed. Renew caulking and seal all penetrations in watertight bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Caulking was renewed and all penetrations in watertight bulkheads were sealed.
Engineering › Fuel Oil Service System › Filter
Issued 8 May 2017
Resolved
Engine room fuel filter is missing flame shield. Install flame shield or change filter type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Flame shield on fuel filter was installed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 May 2017
Resolved
MSD treatment pump removed for servicing. Install MSD pump to satisfaction of the attending CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Pump for MSD was installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 May 2016
Resolved
Light on magnetic compass disabled. Reconnect wiring and prove operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 8 June 2016
Resolution: Compass can now be illuminated.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 May 2016
Resolved
Forward lifejacket storage compartment can be locked. Disable or remove locking mechanism.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 8 June 2016
Resolution: Locking mechanism to lifejacket stowage was removed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 May 2016
Resolved
First watertight bulkhead not watertight at PVC pipe. Properly fill in void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 8 June 2016
Resolution: Foam was used to make area surrounding PVC pipe watertight.