← All vessels
SPLASH ISLAND
- Built
- 2000
- Last inspected
- 28 August 2000
- Deficiencies
- 18 recorded · 4 without a recorded resolution
- Controls
- None recorded without a removal date
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Inspection record
Last inspected
28 August 2000
Deficiencies
18 recorded · 4
without a recorded resolution
…past their stated due date4
Operational controls
None recorded without a removal date
Years with a record
1 calendar year (2000)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
11169
Flag
UNITED STATES
Tonnage
—
Maury page id
psix-11169
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
28 August 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1059221
2 August 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 823651
1 July 2000
COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361581
Deficiency record · 18
Deck/Cargo
Issued 2 August 2000
Resolved
Anchor barge in accordance with the previously submitted and USCG reviewed securing plan.
Fire Fighting
Issued 2 August 2000
Resolved
Properly mount all fire extinguishers.
Lifesaving
Issued 2 August 2000
Resolved
Evenly space out the vessel life ring buoys and attach a 60 feet buoyant lifeline to one.
Unknown
Issued 1 July 2000
No resolution recorded
Conduct required crew drug/alcohol training.
Unknown
Issued 1 July 2000
No resolution recorded
Provide covered number of employees (licensed/unlicensed) for chemical testing program.
Documentation
Issued 1 July 2000
No resolution recorded
Provide vessel's drydocking plan.
Accommodation/Occupational Safety
Issued 1 July 2000
Resolved
Install protection on all steel cleat corners and turnbuckle supports.
Accommodation/Occupational Safety
Issued 1 July 2000
Resolved
Install protection to the interior edges of the exterior pools.
Documentation
Issued 1 July 2000
Resolved
Provide/implement complete operations manual as per described list.
Accommodation/Occupational Safety
Issued 1 July 2000
Resolved
Provide/post safety instructions.
Lifesaving
Issued 1 July 2000
Resolved
Provide securing strap extensions to the Type III life preservers. PFD's must be able to fit all sizes of people.
Accommodation/Occupational Safety
Issued 1 July 2000
Resolved
Install mid and lower rail courses at all openings.
Documentation
Issued 1 July 2000
Resolved
Provide written company designation letter of person in charge.
Unknown
Issued 1 July 2000
No resolution recorded
Conduct required supervisor drug & alcohol training (60 min).
Accommodation/Occupational Safety
Issued 1 July 2000
Resolved
Install escape ladders for both exterior pools.
Lifesaving
Issued 1 July 2000
Resolved
Install permanent safety netting to the center swimming pool.
Navigation
Issued 1 July 2000
Resolved
Permanently mount anchor light.
Lifesaving
Issued 1 July 2000
Resolved
Provide additional 30" CG approved ring buoy.