GIZEMDENIZ SULTAN is a 2006 tank ship. The Coast Guard has recorded 5 inspections since 2016, most recently in January 2020, along with 4 deficiencies.
Records from 2016 to 2020. Most recent: inspection, 30 January 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it3934 - Convention (Subpart B), Gross Ton 1771 - Convention (Subpart B), Net Ton 8082 - Displacement, Ton 5795 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
30 January 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6899833
23 December 2019Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6878326
25 November 2019Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6866238
7 November 2019Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6851577
4 September 2016ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5986282
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 23 November 2019Resolved
INERT GAS SYSTEM - Tank environmental control column H - INERT: inerting (9.1.2.1) PAD: Liquid or gas padding (9.1.2.2) dry:drying (9.1.2.3). PSCO observed the installed Nitrogen Generator was not working. Due to the small deadweight of 5794MT and cargo tank capacity less than 3000m3 SOLAS II-2/4.5.5 is not applicable, however the IBC Code requires certain cargos to be inerted, padded or dryed as shown in Chapter 17 column 14. Until the vessel can prove proper operation of the Nitrogen Generator and Oxygen content monitor it cannot carry (Load or Discharge) any cargos with "Inert, pad, or Dry" listed in column H of Chapter 17.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 December 2019
Resolved 23 December 2019
Resolution: IG system was repaired and the [name withheld] Panel Wiew 300 Micro Software was replaced by technician MOS WORLDWIDE SERVICES L.P. and tested and considered satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 23 November 2019Resolved
Condition after survey
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port State Control Officer observed the fixed gas detection required by SOLAS (04) II-2/4 5.7.2.2 is not operating as designed. However the vessel has 3 portable instruments meeting SOLAS (04) II-2/4 5.7.1 with sufficient flexible hoses to test double bottom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2019
Resolved 25 November 2019
Resolution: Vessel cre overhaul sample pump and reassemble the unit. Tested at the presence of attending surveyor and found satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 23 November 2019Resolved
High level alarm must be identified with the legend "HIGH-LEVEL ALARM" in black letters on a white background. High level is white lettering on orange.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2019
Resolved 25 November 2019
Resolution: Vessel crew painted the "High Level Alarm" with black letters over a white background. Attending surveyor verified and found satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 23 November 2019Resolved
Tank overfill alarm must be identified with the legend "TANK OVERFILL ALARM" in black letters on a white background. Is white lettering on orange.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2019
Resolved 25 November 2019
Resolution: Vessel crew painted the "Tank Overfill Alarm" with black letters over a white background. Attending surveyor verified and found satisfactory.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.