Records from 2017 to 2025. Most recent: inspection, 1 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,158 / net 347
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
1158 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
347 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
10 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
1 April 2025
MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8103506
11 March 2024
COI Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7872201
26 November 2019
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6861866
18 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599815
8 November 2018
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6577941
23 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6571393
9 February 2018
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6352504
31 October 2017
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6301832
7 September 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6298265
9 January 2017
Ballast Water Examination · Annual Inspection · MTSA Verification · VRP Review · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6073356
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 April 2025
Resolved
Each liferaft must be capable of flot-free launching and be arranged as follows: each lifefloat must be individually attached to the group's single painter by its own painter. Lifefloats were improperly stowed. Make correction as per required stowage.
46 CFR 133.130(c)(3)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Vessel rep sent photos showing correct arrangement for float free to the satisfaction of the Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Tables of working hours
Issued 1 April 2025
Resolved
A licensed individual may not be required to work more than 12 of 24 hours at sea. 02 crew members logged 24 hrs work/watches on 07NOV24, 17DEC24, and 18MAR25. Corretced through training.
46 u.s.c. 8104(b)
Action required: 10 - Deficiency Rectified
Resolved 1 April 2025
Resolution: Conducted training with master and vessel rep while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 1 April 2025
Resolved
Each engine of a rescue boat must be run ahead and astern for not less than 3 minutes. Weekly test on rescue boat was not being conducted and/or logged. Corrected through onboard training.
46 CFR 131.560(b)
Action required: 10 - Deficiency Rectified
Resolved 1 April 2025
Resolution: Corrected onbaord through training.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 November 2019
Resolved
Emergency escape hatches must be properly watertight. STBD esacpe hatch in engine room is not watertight, vsl must adjust hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2019
Resolved 27 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019
Resolved
On each metallic vessel, a grounded distribution system must be grounded to the hull. Inspectors ovserved a ground detection on the 480V Bus B Phase C Supply.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 28 November 2019
Resolution: ABS Surveyor [name withheld] witnessed proper operation of main switchboard and ground fault detection on USCG behalf. Def cleared. -SM
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019
Resolved
Nonmetallic flexible hose may be used in lube oil, fuel oil, and fluid power systems. Inspectors observed wasted low pressure fuel hose on port MDE and wasted diesel return lines from both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2019
Resolved 27 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019
Resolved
Each vessel must have a means of communication between the navigating bridge and engine control room. Inspectors observed sound powered phone for internal communication in engine room that was defective.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2019
Resolved 27 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 November 2019
Resolved
No means may be provided for locking an exterior door used as a means of escape unless it is always operable from the inside.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 27 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 November 2019
Resolved
Each life float mus tbe fitted with type-II retro-reflective material. Life floats found with non-approved DOT-style tape.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 27 November 2019