Records from 2014 to 2025. Most recent: inspection, 16 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
16 December 2025
COI Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8276719
26 June 2025
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8161806
4 June 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7927047
1 December 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7602063
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573596
19 September 2022
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7561765
19 January 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7381926
13 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7075937
3 September 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7046610
4 September 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6803830
29 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6615960
28 September 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6550159
6 November 2017
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6296167
30 January 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6079795
6 September 2016
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5974995
17 September 2015
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5231341
23 October 2014
DAPI Audit · Hull Examination · Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4992576
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2024
Resolved
Vessel must undergo a annual inspection within 3 months before or after each anniversary date. Vessel's COI anniversary date is October 22nd and last annual was due no later than January 22nd, 2024.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2025
Resolution: Upon completion of the COI inspection on 16DEC2025, the deficeincy is considered rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 December 2022
Resolution: Vessel underwent a successful annual inspection (Activity 7602063) and no damage affecting the safety and seaworthness of the vessel was identified.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 January 2017
Resolved
The Certificate of Inspection for the ISLAND SUN expired on January 28, 2017
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 3 February 2017
Resolution: The vessel's Second Annual Inspection was completed with no deficiencies noted. The COI was endorsed and the "No sail" Order was rescinded.
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 23 October 2014
Resolved
Lifering does not have the appropriate amount of retroreflective material.
Action required: 705 - Other - as specified
Resolved 28 October 2014
Resolution: Retroreflective tape was placed on the lifering.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 23 October 2014
Resolved
Name and hailing port is not on the vessel.
Action required: 705 - Other - as specified
Resolved 12 November 2014
Resolution: Owner emailed photos of the vessel properly marked with name and hailing port.