Offshore Supply Vessel · Offshore class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named C-CONFIDENCE
C-CONFIDENCE is a 2012 offshore supply vessel. The Coast Guard has recorded 19 inspections since 2012, most recently in June 2026, along with 25 deficiencies and 2 casualty investigations between 2014 and 2016.
Records from 2012 to 2026. Most recent: inspection, 9 June 2026.
- Built
- 2012
- Last inspected
- 9 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2014–2016
Identity
1236257
9619880 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG3712
1118720
Flag
UNITED STATES
366757000
Maury page id
psix-1118720
Inspections, by type
…with no type recorded1
Years with a record
13 calendar years (2012–2026)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)278.4 ft × 60.0 ft × 26.0 ft
Registered tonnagegross 4,032 / net 2,425
ITC dimensions (L × B × D)278.4 ft × 60.0 ft × 26.0 ft
ITC tonnagegross 4,032 / net 2,425
BuilderLA Ship LLC · HOUMA, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4032 - Convention (Subpart B), Gross Ton
2425 - Convention (Subpart B), Net Ton
5097 - Dead Weight, Gross Ton
2425 - Convention (Subpart B), Net Ton
5097 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG3712MMSI 366757000 · active · compulsorily equipped · granted 7 April 2022, expires 3 May 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 19
9 June 2026
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8395834
21 October 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268487
19 May 2025
ACP COI Oversight · MTSA/ISPS Verification · Annual Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8136598
9 May 2024
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884075
25 October 2023
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7814316
16 May 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7674783
15 September 2022
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7528353
3 May 2021
ACP COI Oversight · Periodic Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188152
15 July 2020
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · COI Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7007268
9 June 2020
ACP Drydock Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6972401
19 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6858210
4 May 2018
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6405520
16 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6288911
16 May 2017
COI Inspection · Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6147641
7 June 2016
ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5900140
24 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5886358
27 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6009559
5 May 2014
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4817762
30 January 2012
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4398391
Deficiency record · 25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2026
Resolved
The emergency bilge system failed to operate as designed during testing. Two of the seven bilge suctions worked only after maintence was done. Prove all seven bilge suctions are working as designed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 May 2024
Resolved
For the purpose of this regulation, the requirements of the code shall be treated as mandatory. In meeting these requirements, the company should ensure that: .1 Inspections are held at appropriate intervals. MI found the nitrogen generator oxygen analyzer is not being calibrated quarterly as indicated in the operations manual. Calibrate the sensor, and conduct testing of the alarms as required by the instructions. Conduct training with the personnel that operate the generator to be familiar with the procedures. Scheduled maintenance needs to be added to the vessel's preventative maintenance SMS. SOLAS (20) IX/3.1, ISM Code 10.2.1
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 September 2022
Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at seas are to be sliding watertight doors capable of being remotely closed from the bridge and are also operated locally from each side of the bulkhead. MI found major hyd leak on actuator for the steering gear compartment class III door. 74 SOLAS 2020 II-1/13-1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022
Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine test to ensure continuous reliable operation. It was noted on CE turnover notes dated 11 Aug 2022 (There is issues with port side SSDGs 1 and 2 - when on DP the running generators reached load limit of 70% the standby gen will not automatically start and assist with the load sharing as per required automation/DP procedures. Conduct troubleshooting and repairs prior to conducting DP operations. 74 SOLAS 2020 II-1.46.2
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 September 2022
Resolved
The inert gas system for tankers required in accordance with regulation 4.5.5.1 shall be operated as to render and maintain the atmosphere of the cargo tanks non flammable, except when such tanks are required to be gas free. During inspection vessel personnel could not provide any procedures for operation and maintenance for the Nitrogen Generator System onboard. Furthermore, vessel personnel was not properly trained to operate/maintain such equipment. Vessel is not permitted to load/discharge cargoes that require the use of the Inert Gas System. 74 SOLAS II-2/16.3.3.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 September 2022
Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements with maybe established by the company. Vessel personnel could not provide maintenance records or procedures and operating procedures for the Nitrogen Generator System.
Company shall provide Non conformity and corrective action plan with in 30 days. 74 SOLAS 2020 IX/3.1 ISM Code 10.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 September 2022
Resolved
Cargo tanks shall be fitted with gauging devices. Marine Inspector observed tank level indicator not working as intended on the starboard methanol cargo tank. Such tank shall not be loaded until proper repairs are made. 74 SOLAS 2020 VII/10.1 IBC Code 13.1.1
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 15 July 2020
Resolved
Every ship shall be provided with radio installations capable of complying with the functional requirements prescribed by regulation 4 of 74SOLAS(14)IV. Noted issue with ship's ability to use IMARSAT C due to technical errors & error code on VDR due to internal clock error. FCC technician on-board was conducting inspection and did not issue CSSR w/ form R or bridge-to-bridge radio certificate due to radio installation issues. Owner shall make effective repairs to radio installations and deficiency to be cleared prior to movement. Deficiency will be cleared once all surveys are complete and all applicable FCC documents/certificates are issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Noted expired water light battery and inoperable water light on 03 level w/ vessel's life rings. Noted multiple wasted and missing SOLAS tape on life rings. Owner shall make repairs to life-saving appliances to maintain in a working order.
Personnel › Training › Fast Rescue Boat
Issued 27 June 2016
Resolved
The SOLAS training manual was missing rescue boat launching and safety instructions.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 June 2016
Resolved
. Upon arrival the fire detection system alerted heat detection in the starboard acid room/ upper level- heat sensor found to be faulty. Alarm started sounding on the bridge.
Construction/Loadline › Markings › Load Line Mark
Issued 27 June 2016
Resolved
Port load line markings were not visible in contrasting color to the hull.
Electrical › Electric Generation Source (emergency) › Grounding Conductor
Issued 27 June 2016
Resolved
E-generator was not properly bonded to vessel.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 27 June 2016
Resolved
Two of the zone levers for the manual operation of the Frac plant Water Mist system were missing the control levers. Bolts were temporarily fitted to the controls to allow manual operation of the system if needed.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 27 June 2016
Resolved
In the water mist room, actuation instructions were confusing and directed you to a lever that wasn't properly labeled.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 5 May 2014
Resolved
Vessel had Node #2 failure in its automation/DP system. Vessel did not report the incident nor has it corrected the issue. Make appropriate repairs and provide a 3rd party tech report to the satisfaction of the attending USCG inspector or ABS surveyor.
Deck/Cargo › Cargo Stowage › General
Issued 5 May 2014
Resolved
Vessel has various hazmat stowed together, but Master nor crew are aware of compatibility status. Immediately, within 24 hours, determine compatibility requirements are met. Develop a mutual agreement between "frac-house" and vessel personnel to ensure compat requirements are met and maintained.
Fire Fighting › Nozzles › Condition
Issued 5 May 2014
Resolved
The vessel's "frac-house" is protected by a water-mist system. Several nozzles were corroded and inspector's question the ability of the nozzles to properly mist. Provide 3rd party report of proper operation of the system, proof of an operators manual and appropriate recommended spare parts.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 May 2014
Resolved
During e-gen test, observed 03 e-flood lights not working.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 5 May 2014
Resolved
Both bridge SART's were zip tied and needed to be snipped with pliers prior to testing.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 May 2014
Resolved
While testing the aft WTD, it stopped and would not operate unless done by hand.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2014
Resolved
Smoke detectors in both upper and lower laundry rooms would not operate. Crew is to conduct hourly rounds of these spaces until resolved.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 May 2014
Resolved
Several self-closing doors were found to be unable to close completely without manual assistance. Make appropriate adjustments/repairs.
Deck/Cargo › Cargo Stowage › General
Issued 5 May 2014
Resolved
Issued one reqirement for 13 observations in the Frac-House to be rectified in 30 days. 835 scanned into vessel docs,
Deck/Cargo › Cargo Stowage › General
Issued 5 May 2014
Resolved
On 18JUL14, Master was issued a 24 hour requirement to verify compat and segragation requirements were met. Vessel was attended again on 20JUL14. Verification had not been conducted. Issued requirement to verify compat and seg prior to conducting cargo ops. In addition, an ISM audit for the carriage of dangerous goods was required and to be scheduled within two weeks. Provide ISM results to USCG.
Casualty record · 2
6 December 2014Routine · role: Involved in a Marine Casualty · activity 5036950
27 February 2016Routine · role: Involved in a Marine Casualty · activity 6009559
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
DEEPSTIM BRASIL II (2014–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.