MAURY USCG vessel records
← All vessels

C-CONFIDENCE

C-CONFIDENCE is a 2012 offshore supply vessel. The Coast Guard has recorded 17 inspections since 2016, most recently in June 2026, along with 15 deficiencies and 2 casualty investigations between 2014 and 2016.

Records from 2014 to 2026. Most recent: inspection, 9 June 2026.

Built
2012
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9619880
WDG3712
1118720
Flag
UNITED STATES
Maury page id
psix-1118720

Documentation record

Registered dimensions (L × B × D)278.4 ft × 60.0 ft × 26.0 ft
Registered tonnagegross 4,032 / net 2,425
ITC dimensions (L × B × D)278.4 ft × 60.0 ft × 26.0 ft
ITC tonnagegross 4,032 / net 2,425
BuilderLA Ship LLC · HOUMA, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4032 - Convention (Subpart B), Gross Ton
2425 - Convention (Subpart B), Net Ton
5097 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

9 June 2026 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8395834
21 October 2025 ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268487
19 May 2025 ACP COI Oversight · MTSA/ISPS Verification · Annual Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8136598
9 May 2024 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884075
25 October 2023 ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7814316
16 May 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7674783
15 September 2022 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7528353
3 May 2021 ACP COI Oversight · Periodic Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188152
15 July 2020 Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · COI Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7007268
9 June 2020 ACP Drydock Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6972401
19 November 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6858210
4 May 2018 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6405520
16 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6288911
16 May 2017 COI Inspection · Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6147641
7 June 2016 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5900140
24 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5886358
27 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6009559

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2026 Resolved
The emergency bilge system failed to operate as designed during testing. Two of the seven bilge suctions worked only after maintence was done. Prove all seven bilge suctions are working as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2026
Resolution: ABS report saated "The bilge systems have been re-inspected and operationally tested to the satisfaction of the attending ABS surveyor, and its operations were found to be satisfactory."
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 May 2024 Resolved
For the purpose of this regulation, the requirements of the code shall be treated as mandatory. In meeting these requirements, the company should ensure that: .1 Inspections are held at appropriate intervals. MI found the nitrogen generator oxygen analyzer is not being calibrated quarterly as indicated in the operations manual. Calibrate the sensor, and conduct testing of the alarms as required by the instructions. Conduct training with the personnel that operate the generator to be familiar with the procedures. Scheduled maintenance needs to be added to the vessel's preventative maintenance SMS. SOLAS (20) IX/3.1, ISM Code 10.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 22 May 2024
Resolution: Accepted as condition of class, finding #464 (ABS).
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 September 2022 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at seas are to be sliding watertight doors capable of being remotely closed from the bridge and are also operated locally from each side of the bulkhead. MI found major hyd leak on actuator for the steering gear compartment class III door. 74 SOLAS 2020 II-1/13-1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2022
Resolution: ABS accepted as a condition of class
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine test to ensure continuous reliable operation. It was noted on CE turnover notes dated 11 Aug 2022 (There is issues with port side SSDGs 1 and 2 - when on DP the running generators reached load limit of 70% the standby gen will not automatically start and assist with the load sharing as per required automation/DP procedures. Conduct troubleshooting and repairs prior to conducting DP operations. 74 SOLAS 2020 II-1.46.2
Action required: 705 - Other - as specified
Resolved 19 September 2022
Resolution: ABS accepted as a condition of class
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 September 2022 Resolved
The inert gas system for tankers required in accordance with regulation 4.5.5.1 shall be operated as to render and maintain the atmosphere of the cargo tanks non flammable, except when such tanks are required to be gas free. During inspection vessel personnel could not provide any procedures for operation and maintenance for the Nitrogen Generator System onboard. Furthermore, vessel personnel was not properly trained to operate/maintain such equipment. Vessel is not permitted to load/discharge cargoes that require the use of the Inert Gas System. 74 SOLAS II-2/16.3.3.1
Action required: 705 - Other - as specified
Resolved 19 September 2022
Resolution: ABS accepted as a condition of class
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 September 2022 Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements with maybe established by the company. Vessel personnel could not provide maintenance records or procedures and operating procedures for the Nitrogen Generator System. Company shall provide Non conformity and corrective action plan with in 30 days. 74 SOLAS 2020 IX/3.1 ISM Code 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2022
Resolution: ABS accepted as a condition of class.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 September 2022 Resolved
Cargo tanks shall be fitted with gauging devices. Marine Inspector observed tank level indicator not working as intended on the starboard methanol cargo tank. Such tank shall not be loaded until proper repairs are made. 74 SOLAS 2020 VII/10.1 IBC Code 13.1.1
Action required: 705 - Other - as specified
Resolved 19 September 2022
Resolution: ABS accepted as condition of class.
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 15 July 2020 Resolved
Every ship shall be provided with radio installations capable of complying with the functional requirements prescribed by regulation 4 of 74SOLAS(14)IV. Noted issue with ship's ability to use IMARSAT C due to technical errors & error code on VDR due to internal clock error. FCC technician on-board was conducting inspection and did not issue CSSR w/ form R or bridge-to-bridge radio certificate due to radio installation issues. Owner shall make effective repairs to radio installations and deficiency to be cleared prior to movement. Deficiency will be cleared once all surveys are complete and all applicable FCC documents/certificates are issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
Resolution: Radio surveys completed, no discrepancies and all certs issued to vsl.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Noted expired water light battery and inoperable water light on 03 level w/ vessel's life rings. Noted multiple wasted and missing SOLAS tape on life rings. Owner shall make repairs to life-saving appliances to maintain in a working order.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 17 July 2020
Resolution: Received picture of corrected life rings and receipt for new batteries.
Personnel › Training › Fast Rescue Boat
Issued 27 June 2016 Resolved
The SOLAS training manual was missing rescue boat launching and safety instructions.
Due 27 June 2016
Resolved 27 June 2016
Resolution: Corrected on the spot.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 June 2016 Resolved
. Upon arrival the fire detection system alerted heat detection in the starboard acid room/ upper level- heat sensor found to be faulty. Alarm started sounding on the bridge.
Due 27 June 2016
Resolved 27 June 2016
Resolution: heat sensor found to be faulty, replaced and tested/ corrected on the spot. heat sensor found to be faulty, replaced and tested/ corrected on the spot. heat sensor found to be faulty, replaced and tested/ corrected on the spot.
Construction/Loadline › Markings › Load Line Mark
Issued 27 June 2016 Resolved
Port load line markings were not visible in contrasting color to the hull.
Due 27 July 2016
Resolved 27 June 2016
Resolution: Outstanding condition of class.
Electrical › Electric Generation Source (emergency) › Grounding Conductor
Issued 27 June 2016 Resolved
E-generator was not properly bonded to vessel.
Due 27 July 2016
Resolved 27 June 2016
Resolution: Outstanding condition of class
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 27 June 2016 Resolved
Two of the zone levers for the manual operation of the Frac plant Water Mist system were missing the control levers. Bolts were temporarily fitted to the controls to allow manual operation of the system if needed.
Due 27 July 2016
Resolved 27 June 2016
Resolution: Outstanding condition of class.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 27 June 2016 Resolved
In the water mist room, actuation instructions were confusing and directed you to a lever that wasn't properly labeled.
Due 27 June 2016
Resolved 27 June 2016
Resolution: Bad instructions were removed. New instructions were posted.

Casualty record · 2

6 December 2014Routine · role: Involved in a Marine Casualty · activity 5036950
27 February 2016Routine · role: Involved in a Marine Casualty · activity 6009559
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DEEPSTIM BRASIL II (2014–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.