← All vessels
PS ROMA
PS ROMA is a 2011 tank ship. The Coast Guard has recorded 15 inspections since 2017, most recently in December 2025, along with 19 deficiencies and 2 operational controls.
Records from 2017 to 2025. Most recent: inspection, 4 December 2025.
- Built
- 2011
- Last inspected
- 4 December 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2017–2025)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it29717 - Convention (Subpart B), Gross Ton
13609 - Convention (Subpart B), Net Ton
51062 - Dead Weight, Metric Ton
61343 - Displacement, Metric Ton
13609 - Convention (Subpart B), Net Ton
51062 - Dead Weight, Metric Ton
61343 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 15
4 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8277686
21 November 2025
PSC B · COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8270705
29 September 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8243460
24 November 2024
COC-CHEM & TVE Renew · Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8038021
20 August 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7772333
12 October 2022
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7571288
7 October 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7573404
31 January 2022
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7388535
28 January 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7387398
24 September 2021
PSC C · Deficiency Check · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7317090
24 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7145667
21 January 2021
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7128468
19 April 2020
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6941160
18 April 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6940814
6 June 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6160128
Deficiency record · 19
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2025
Resolved
74SOLAS(20)VII/10.1 IBC CODE 10.2.2.1
ELECTRICAL INSTALLATIONS SHALL BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS. PSCO OBSERVED 01 EXPLOSION PROOF LIGHT MISSING GROUNDING WIRE AND 01 EXPLOSION PROOF LIGHT WITH COMPROMISED GLANDS NEAR STARBOARD SIDE LADDER TO FORECASTLE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2025
Resolved
74SOLAS(20)II-2/4.1.1
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF FLAMMABLE LIQUIDS. THE FOLLOWING FUNCTIONAL REQUIREMETNS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL LEAK FROM POWER PACK FOR CARGO PUMPS IN ENGINE ROOM.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 November 2025
Resolved
74SOLAS(20)II-2/4.5.7.3.1 FSS CODE 16.2.2.2.1.4
AT A GAS CONCENTRATION OF 30% OF THE LOWER FLAMMABLE LIMIT INSIDE THE STEEL ENCLOSURE THE ENTIRE GAS ANALYZING UNIT IS TO BE AUTOMATICALLY SHUT DOWN. PSCO OBSERVED SETPOINT FOR LEL ON HYDROCARBON DETECTION SYSTEM AT 50%
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 21 November 2025
Resolved
ICLL 66 ANNEX I REG 08
THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK BACKGROUND. PSCO OBSERVED FRESH WATER ALLOWABLE LINE NOT PAINTED IN CONTRASTING COLOR.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 21 November 2025
Resolved
46CFR39.3001(c)(2)
FOR EACH CARGO TRANSFERRED USING A VAPOR COLLECTION SYSTEM (VCS) THE PRESSURE DROP MUST BE CALCULATED USING A DENSITY ESTIMATE FOR THE CARGO VAPOR. PSCO OBSERVED VCS LETTER MISSING CARGO DENSITY AND STATEMENT THAT INERT GAS SYSTEM COMPLIES WITH 49 CFR 32.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 24 November 2024
Resolved
TANKERS SHALL BE EQUIPPED WITH AT LEAST ONE PORTABLE INSTRUMENT FOR MEASURING OXYGEN.
PSCO OBSERVED BOTH METERS USED TO MEASURE OXYGEN WITH INOPERABLE 02 SENSORS.
74 SOLAS (2020)
II-2/4.5.7.1
17AC
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2024
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS.
PSCO OBSERVED TWO EXPLOSION PROOF LIGHTS (BATTERY ROOM BRIDGE AND PORTSIDE CARGO DECK ON FORWARD SUPER STRUCTURE) WITH COMPROMISED GLANDS AND MISSING GROUNDING WIRES.
74 SOLAS (2020)
VII/10.1
IBC CODE 10.1.2.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 November 2024
Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION THEY ARE FITTED, THIS BEING DETTERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE. DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATERGOTY A SHALL BE RESONABLE GASTIGHT AND SELF CLOSING.
PSCO OBSERVED A-60 SELF CLOSING FIRE DOORS TO THE ENGONE ROOM FROM UPPER DECK AND ENGINE CHANGING ROOM UNABLE TO PROPERLY LATCH. ADDITIONALLY, PSCO OBSERVED A-0 SELF CLOSING FIRE DOOR FROM FIRE LOCKER TO MAIN STAIRWELL MISSING SELF CLOSING DEVICE AND FITTED WITH A HOLDBACK HOOK. FINALLY PSCO OBSERVED A-CLASS FIRE DOOR FROM AIR CONDITIONING ROOM TO MAIN STAIRWELL UNABLE TO PROPERLY LATCH.
74 SOLAS (2020)
II-2/9.4.2.1
17AC
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 24 November 2024
Resolved
SUCH CERTIFICATE SHALL BE ISSUED OR ENDORSED AS APPROPRIATE EITHER BY THE ADMINISTRATION OR BY ANDY PERSON OR ORGANIZATION DULY AUTHORIZED BY IT. IN EVERY CASE THE ADMINISTRATION ASSUMES FULL RESPONSIBILITY FOR THE CERTIFICATE.
PSCO OBSERVED IOPP MISSING INFORMATION IN BLOCKS 2 THROUGH 5. TO INCLUDE OWS THROUGH PUT, SLUDGE TANKS, BILGE HOLDING TANKS, BALLAST TANKS, ECT.
MARPOL ANNEX 1
REG 7.2
17AC
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 24 November 2024
Resolved
WHERE "A" CLASS DIVIDIOND ARE PENETRATED... SUCH PENETRATIONS SHALL BE SUTABLE INSULATED AT EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION.
PSCO OBSERVED MULTIPLE CABLE RUNS IN THE A,B, AND C DECK PIPE/CABLE PORTS ARE MISSING INSULATION.
74 SOLAS (2004)
II-2/9.3.1
16AC
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 24 November 2024
Resolved
THE RATING OR APPROPRIATE SETTING OF THE OVERLOAD PROTECTIVE DEVICE FOR EACH CIRCUT SHALL BE PREMANENTLY INDICATED AT THE LOCATION OF THE PROTECTIVE DEVICE.
[name withheld] CIRCUT BREAKERS ON THE MAIN SWITCHBOARD FOR BWMS 1 AND 2 ARE MISSING THE OVERLOAD PROTECTIVE DEVICE RATING 1 SETTING.
74 SOLAS (2014)
II-1/45.6.2
16AC
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 November 2024
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 2 OF THIS REGULATION SHALL COMPLY WITH PARAGRAPH 5 OF THIS REGULATION. IN ADDITION IT SHALL BE PREVIDED WITH ALARM.ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED THE SYSTEM ALSO BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15PPM. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVAL, THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION.
PSCO OBSERVED OWS SYSTEM LEAKING FROM THREADED PROTECTION FROM ON TOP OF FILTERING EQUIPMENT.
MARPOL ANNEX 1
REG 13.7
16AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2022
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL MASTER REPORTED WATER INGRESS THROUGH THE OUTER STERN TUBE SEAL. THIS RESULTED IN THE FAILURE OF THE PRIMARY OIL SEAL. THE BACKUP OIL SEAL 3S WAS ENGAGED IN ACCORDNACE WITH MANUFACTURERS INSTRUCTIONS. 74 SOLAS (2020) CHAPTER I REGULATION IIa
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 24 September 2021
Resolved
A secondary means of allowing full flow relief of vapor or alternatively a pressure sensor must be fitted to each tank. Vessels installed pressure guages are incorporated to tank radar system which is inoperable.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 24 September 2021
Resolved
Oil Record Book shall be preserved for the last three years after the last entry has been made. Vessel does not have complete records prior to 06JUL2021
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 24 September 2021
Resolved
IOPP shall be drawn up in a form corresponding to appendix II of annex I. Vessel is equipped with segregated ballast tanks, however tanks are not noted on IOPP supplement.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 18 April 2020
Resolved
The International Oil Pollution Certificate shall be drawn up in the form corresponding to the model given in Appendix II to this Annex. PSCO observed maximum throughtout of the oil filtering equipment noted in section 2.4 was not listed.
Marpol Annex I/9
16ac
Deck/Cargo › Cargo Stowage › General
Issued 6 June 2017
Resolved
The stowage space shall be: cell divided in order to avoid shifting of the bottles at sea. Samples shall not be retained on board longer than necessary. Sample locker found overly full, disorganized, and contained samples over 2 years old. Annex I & II cargo and bunker samples were not segregated. IBC 16.5.2.1 & 16.5.4- 50ac
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 6 June 2017
Resolved
Ships shall have on board sufficient but not less than three complete sets of safety equipment, each permitting personnel to enter a gas filled compartment. 01 safety suit found with an unsealed seam on mask-piece. IBC 14.2.1- 40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.