Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 12
17 March 2026
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8308336
7 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8111547
27 March 2024
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884901
3 April 2023
Administrative Inspection · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671160
30 March 2022
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7423121
30 March 2021
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7167811
22 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072473
13 March 2019
Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6641783
22 March 2018
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6399155
29 July 2017
Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6226742
17 April 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131886
14 March 2016
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5833798
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 March 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
02 air leaks were discovered during overpressure leak test:
- Starboard Sponson: underside of chamber 3, underside of fwd chamber
46 CFR 177.100
JOINT CGD13/17INST 16711.1A 9.c.3
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2026
Resolution: O/o repaired damage and conducted satisfactory overpressure test
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
04 air leaks were discovered during working pressure leak test and delamination was observed on the starboard end of the inflatable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 2 June 2025
Resolution: Superceded, approved inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25.
Portable fuel tank was not secured in accordance with ABYC H-25.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 2 June 2025
Resolution: Superceded, approved inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2024
Resolved
The following items shall be carried onboard all inflatables: Pressure gauge to check individual inflatable chambers of the boat.
Inflatable did not have a gauge onboard, vessel o/o had ordered one prior to inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 2 June 2025
Resolution: Superceded, approved inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 27 March 2024
Resolved
State registration, COI, stability letter, life jacket placard, emergency broadcast placard, emergency instructions, and merchant mariner credentials shall be carried onboard each vessel in a suitable waterproof manner.
Merchant mariner credentials were not carried in a suitable waterproof manner.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 2 June 2025
Resolution: Superceded, approved inspection.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 March 2018
Resolved
Blown baffle between number 4 and 5 chambers. Vessel reps are working to replace pontoon. Vessel will be operating as a UPV until pontoon is replaced.
Action required: 705 - Other - as specified
Due 1 August 2018
Resolved 13 March 2019