Records from 2020 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 35
15 April 2026
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8346117
15 April 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8350048
17 March 2026
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8325889
12 February 2026
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8307268
10 February 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308568
9 January 2026
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290880
3 November 2025
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8261190
1 October 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8242114
1 October 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8244969
10 March 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8089453
22 November 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038787
13 September 2024
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8000097
12 August 2024
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7977321
8 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7977294
2 July 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7943840
14 February 2024
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7864184
24 April 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7674637
18 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7669122
31 January 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7627662
27 January 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628096
14 December 2022
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7607027
9 December 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7606958
8 November 2022
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7588391
7 October 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7570868
28 July 2022
Deficiency Check · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7518494
23 June 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7480232
19 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7481374
18 May 2022
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7450408
15 February 2022
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393983
6 October 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7324128
15 March 2021
PSC B · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7153493
15 March 2021
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156924
17 November 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7096708
16 November 2020
Ballast Water Examination · PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094186
12 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094205
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 March 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids... The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids . PSCO observed accumulation of oil around, but not limited to, main propulsion engines, auxiliary generators, aft bilge wells in engine room, and oil purifier space.
74 SOLAS (09) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO observed satisfactory removal of accumulated oil around main propulsion engines, auxiliary generators, aft bilge wells in engine room, and oil purifier space.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 17 March 2026
Resolved
Surfaces with temperatures above 220C which may be impinged as a result of fuel system failure shall be properly insulated. PSCO observed damaged and oil soaked lagging throughout engine room and oil purifier room.
74 SOLAS (09) II-2/4.2.2.6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO observed renewed lagging in engine room and oil purifier room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2026
Resolved
Fire-Fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed inoperable smoke detector above starboard propulsion engine.
74 SOLAS (09) II-2/4.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO observed renewed smoke detector and witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 17 March 2026
Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the fire safety systems code. PSCO observed missing hardware and corroded condition for both international shore connections.
74 SOLAS (09) II-2/10.2.1.7
FSS CODE 2.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO observed international shore connection was cleaned, repainted, and provided with additional hardware.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2026
Resolved
Ships shall be designed/constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed active leakage at two locations on ballast water piping in engine room.
74 SOLAS (04) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO witnessed removal of damaged piping, blanking of connecting piping, and renewal of copper priming line.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2026
Resolved
All electrical apparatus shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. PSCO observed EXPOSED wiring in electrical boxes below all low pressure CO2 compressor temp gauges.
74 SOLAS (04) II-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Following RO attendance, PSCO observed satisfactory installation of protective metal plating.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 March 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: Inspections are held at appropriate intervals. PSCO observed requirements of ISM Code 10.2.1 are not being met.
74 SOLAS (20) IX/3.1
ISM CODE A 10.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2026
Resolution: Reviewed internal audit documents and found satisfactory. See narrative for more details.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 February 2026
Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the purpose of this regulation, the requirement of the code shall be treated as mandatory. The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence. Ship was unable to provide company procedures following 03Feb2026 main engine failure. (SOLAS IX/3; ISM CODE 9.2)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 March 2026
Resolution: Records reviewed & found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2024
Resolved
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. FLAME DETECTOR TESTING EQUIPMENT WAS NOT ABLE TO CONDUCT AN APPROPRIATE TEST.
CITE: SOLAS 74 (2009 CONSOLIDATED) II-2/14.2.2.1
ACTION CODE: 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 September 2024
Resolution: New flame detector testing equipment was installed and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 December 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel master reported cargo space ventilation indicators on the bridge as required by SOLAS II-2 Regulation 20.3.1.3.
74 SOLAS 20 II-2 11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 January 2023
Resolution: Ventilation indicators on navigation bridge were repaired and operationally tested to the satisfaction of class and USCG.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 7 October 2022
Resolved
Personnel responsible for the operation of an incinerator installed in accordance with requirements of paragraph 6.1 of this regulation shall be trained to implement the guidance provided in the manufacturer's operating manual as required by paragraph 7 of this regulation. PSCO observed that crew did not have knowledge to run incinerator. MARPOL VI/16.8.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 November 2022
Resolution: Witnessed satisfactory test of incinerator by ship's crew. Examined incinerator operation procedures.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 October 2022
Resolved
Any failure of oil filtering equipment shall be recorded in the oil record book part 1. PSCO observed no entry was made in oil record book part 1 when OWS was found to be inoperable. MARPOL I/17.5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 7 October 2022
Resolution: Corrected during exam. C/E made entry into ORB prior to completion of the exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as required in table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter. PSCO observed vessel does not have transfer procedures. 33CFR 155.720
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 August 2022
Resolution: Received Transfer Procedures from the vessel meeting the requirements outlined in 33CFR 155.720.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 May 2022
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED OIL ACCUMULATION IN ENGINE ROOM BILGE AND DECK GRATINGS FROM SIGNIFICANT MAIN ENGINE OIL LEAKS THROUGHOUT THE ENGINE BLOCK AND ITS ASSOCIATED SYSTEMS. EXCESSIVE OIL WAS ALSO FOUND IN DRIP PANS AND IN NON-APPROVED CONTAINMENTS MADE OF CANS AND PLASTIC BUCKETS.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 May 2022
Resolution: Recieved class report, vessel risk assessment and plans to get repairs affected next port. Additionally, witnessed onboard the vessel engine was thoroughly cleaned by crew and Chief Engineer implemented a monitoring and reporting schedule posted in E/R
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2022
Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED EXCESSIVE ICE BUILDUP ON THE LOWER #1 COMPRESSOR UNIT PIPING AND SOLENOID VALVES AS WELL AS INCONSISTENT PRESSURES ON GAUGES ACROSS THE SYSTEM RANGING FROM 1.5 MPA TO 6.0 MPA ON THE LOW PRESSURE CO2 SYSTEM, STBD TANK. ADDITIONALLY, TWO GAUGES WERE FOUND TO BE INOPERABLE WITH ONE NEEDLE MISSING AND ONE WITH CONTAMINATED FLUID ON INSIDE BLOCKING THE READING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2022
Resolution: Further inspected the CO2 System; was briefed by the 2nd Engineer that crew added refrigerant on 20May to the system and switched to run the upper compressor. All ice on the lower compressor has melted and pipe condition observed to be satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022
Resolved
Ships shall be designed, constructed, and maintained in compliance with structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. PSCO Observed oil leaking from both Port and STBD main engines
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2022
Resolution: Attended the vessel and observed impressive cleaning of entire engine room including the oil leakage on the main engines
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2021
Resolved
Oil fuel pipes, which if damaged would allow oil to escape from storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom , shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. PSCO observed emergency generator fuel shut off valve inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2021
Resolved 15 March 2021
Resolution: Valve operable before leaving vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted that the engines would not start and deemed inoperable when the vessel tried to depart their berth.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
Resolution: Oil Mist Detector tests conducted by Coast Guard satisfactory. Class report provided by [name withheld] attesting to satisfactory operation of oil mist detectors.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 November 2020
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 1 OF THIS REGULATION SHALL BE OF A DESIGN APPROVED BY THE ADMINISTRATION AND SHALL BE AS WILL ENSURE THAT ANY OILY MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAS AN OIL CONTENT NOT EXCEEDING 15PPM. PSCO OBSERVED OILY WATER SEPARATOR WAS DOWN FOR MAINTENANCE AND UNABLE TO BE TESTED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Verified proper operation of OWS and ensured adequate capacity for Oil generated on board during next voyage. See ACTIVITY #7096708
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 November 2020
Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED. [name withheld] INTO HYDRAULIC PUMP STATION WOULD NOT CLOSE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Verfied that fire door would satisfactorily close under its own power. See ACTIVITY #7096708