← All vessels
VILLE DE BORDEAUX
VILLE DE BORDEAUX is a 2004 freight ship. The Coast Guard has recorded 35 inspections since 2020, most recently in April 2026, along with 20 deficiencies and 2 operational controls.
Records from 2020 to 2026. Most recent: inspection, 15 April 2026.
- Built
- 2004
- Last inspected
- 15 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9270842 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
FZCE
1119341
Flag
FRANCE
—
Maury page id
psix-1119341
Inspections, by type
…with no type recorded3
Years with a record
7 calendar years (2020–2026)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it21528 - Convention (Subpart B), Gross Ton
5991 - Dead Weight, Metric Ton
8918 - Displacement, Metric Ton
5382 - Convention (Subpart B), Net Ton
5991 - Dead Weight, Metric Ton
8918 - Displacement, Metric Ton
5382 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 35
15 April 2026
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8346117
15 April 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8350048
17 March 2026
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8325889
12 February 2026
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8307268
10 February 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308568
9 January 2026
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290880
3 November 2025
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8261190
1 October 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8242114
1 October 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8244969
10 March 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8089453
22 November 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038787
13 September 2024
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8000097
12 August 2024
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7977321
8 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7977294
2 July 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7943840
14 February 2024
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7864184
24 April 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7674637
18 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7669122
31 January 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7627662
27 January 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628096
14 December 2022
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7607027
9 December 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7606958
8 November 2022
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7588391
7 October 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7570868
28 July 2022
Deficiency Check · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7518494
23 June 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7480232
19 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7481374
18 May 2022
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7450408
15 February 2022
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393983
6 October 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7324128
15 March 2021
PSC B · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7153493
15 March 2021
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156924
17 November 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7096708
16 November 2020
Ballast Water Examination · PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094186
12 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094205
Deficiency record · 20
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 March 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids... The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids . PSCO observed accumulation of oil around, but not limited to, main propulsion engines, auxiliary generators, aft bilge wells in engine room, and oil purifier space.
74 SOLAS (09) II-2/4.1.1
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 17 March 2026
Resolved
Surfaces with temperatures above 220C which may be impinged as a result of fuel system failure shall be properly insulated. PSCO observed damaged and oil soaked lagging throughout engine room and oil purifier room.
74 SOLAS (09) II-2/4.2.2.6.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2026
Resolved
Fire-Fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed inoperable smoke detector above starboard propulsion engine.
74 SOLAS (09) II-2/4.2.1.2
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 17 March 2026
Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the fire safety systems code. PSCO observed missing hardware and corroded condition for both international shore connections.
74 SOLAS (09) II-2/10.2.1.7
FSS CODE 2.2.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2026
Resolved
Ships shall be designed/constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed active leakage at two locations on ballast water piping in engine room.
74 SOLAS (04) II-1/3-1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2026
Resolved
All electrical apparatus shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. PSCO observed EXPOSED wiring in electrical boxes below all low pressure CO2 compressor temp gauges.
74 SOLAS (04) II-1/45.1.3
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 March 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: Inspections are held at appropriate intervals. PSCO observed requirements of ISM Code 10.2.1 are not being met.
74 SOLAS (20) IX/3.1
ISM CODE A 10.2.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 February 2026
Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the purpose of this regulation, the requirement of the code shall be treated as mandatory. The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence. Ship was unable to provide company procedures following 03Feb2026 main engine failure. (SOLAS IX/3; ISM CODE 9.2)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2024
Resolved
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. FLAME DETECTOR TESTING EQUIPMENT WAS NOT ABLE TO CONDUCT AN APPROPRIATE TEST.
CITE: SOLAS 74 (2009 CONSOLIDATED) II-2/14.2.2.1
ACTION CODE: 40ac
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 December 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel master reported cargo space ventilation indicators on the bridge as required by SOLAS II-2 Regulation 20.3.1.3.
74 SOLAS 20 II-2 11(a)
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 7 October 2022
Resolved
Personnel responsible for the operation of an incinerator installed in accordance with requirements of paragraph 6.1 of this regulation shall be trained to implement the guidance provided in the manufacturer's operating manual as required by paragraph 7 of this regulation. PSCO observed that crew did not have knowledge to run incinerator. MARPOL VI/16.8.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 October 2022
Resolved
Any failure of oil filtering equipment shall be recorded in the oil record book part 1. PSCO observed no entry was made in oil record book part 1 when OWS was found to be inoperable. MARPOL I/17.5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as required in table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter. PSCO observed vessel does not have transfer procedures. 33CFR 155.720
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 May 2022
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED OIL ACCUMULATION IN ENGINE ROOM BILGE AND DECK GRATINGS FROM SIGNIFICANT MAIN ENGINE OIL LEAKS THROUGHOUT THE ENGINE BLOCK AND ITS ASSOCIATED SYSTEMS. EXCESSIVE OIL WAS ALSO FOUND IN DRIP PANS AND IN NON-APPROVED CONTAINMENTS MADE OF CANS AND PLASTIC BUCKETS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2022
Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED EXCESSIVE ICE BUILDUP ON THE LOWER #1 COMPRESSOR UNIT PIPING AND SOLENOID VALVES AS WELL AS INCONSISTENT PRESSURES ON GAUGES ACROSS THE SYSTEM RANGING FROM 1.5 MPA TO 6.0 MPA ON THE LOW PRESSURE CO2 SYSTEM, STBD TANK. ADDITIONALLY, TWO GAUGES WERE FOUND TO BE INOPERABLE WITH ONE NEEDLE MISSING AND ONE WITH CONTAMINATED FLUID ON INSIDE BLOCKING THE READING.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022
Resolved
Ships shall be designed, constructed, and maintained in compliance with structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. PSCO Observed oil leaking from both Port and STBD main engines
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2021
Resolved
Oil fuel pipes, which if damaged would allow oil to escape from storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom , shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. PSCO observed emergency generator fuel shut off valve inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted that the engines would not start and deemed inoperable when the vessel tried to depart their berth.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 November 2020
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 1 OF THIS REGULATION SHALL BE OF A DESIGN APPROVED BY THE ADMINISTRATION AND SHALL BE AS WILL ENSURE THAT ANY OILY MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAS AN OIL CONTENT NOT EXCEEDING 15PPM. PSCO OBSERVED OILY WATER SEPARATOR WAS DOWN FOR MAINTENANCE AND UNABLE TO BE TESTED.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 November 2020
Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED. [name withheld] INTO HYDRAULIC PUMP STATION WOULD NOT CLOSE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.