VELEBIT

VELEBIT is a 2011 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in July 2026, along with 4 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 20 July 2026.

Built
2011
Last inspected
20 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9455741
9AA7659
1119898
Flag
CROATIA
Maury page id
psix-1119898

Inspections, by type

Years with a record 8 calendar years (2016–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it30638 - Convention (Subpart B), Gross Ton
14202 - Convention (Subpart B), Net Ton
49999 - Dead Weight, Metric Ton
61418 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

20 July 2026 COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8439661
17 March 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8095199
28 February 2025 COC-CHEM Renew
Type not classified · Sector North Carolina · USCG East District (CGD-E) · Activity 8086136
31 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7824881
31 August 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7776973
2 August 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7275515
27 July 2021 COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7268286
6 February 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6903042
17 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6664409
21 March 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6642803
10 February 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6623203
16 March 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6373310
9 August 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5973811
17 July 2016 COC-CHEM Renew · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5933446

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 March 2025 Resolved
Machinery spaces of category A and above 500M3 shall in addition to the fixed fire extinguishing system required in paragraph 5.1.1 must be protected by an approved type water-based fire extinguishing system; Fixed water-based extinguishing system serving IGG space has separated branch lines rendering system inoperable.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 15 March 2025
Resolved 17 March 2025
Resolution: crew replaced piping with material in kind. Tested to class surveyors satisfaction.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 27 July 2021 Resolved
FOR TANKERS OF 20,000 TONNES DEADWEIGHT AND UPWARDS THE PROTECTION OF THE CARGO TANK SHALL BE ACHIEVED BY A FIXED GAS INERT SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE FIRE SAFETY SYSTEM CODE. THE INERT GAS SYSTEM REFERRED TO IN CHAPTER II-2 OF THE CONVENTION SHALL BE DESIGNED CONSTRUCTED AND TESTED TO THE SATISFACTION OF THE ADMINISTRATION, IT SHALL BE DESIGNED TO BE CAPABLE OF RENDERING AND MAINTAINING THE ATMOSPHERE OF THE RELEVANT CARGO TANKS NON-FLAMMABLE. PSCOS OBSERVED INERT GAS WAS UNABLE TO BE STARTED. PRIOR TO CARGO DISCHARGE OPERATION PROVIDE DOCUMENTATION OF CORRECTIVE ACTION./ VESSEL WAS ABLE TO DEMONSTRATE PROPER OPERATION OF INERT GAS GENERATOR PRIOR TO USCG DEPARTURE. DEFICIENCY ISSUED AND CLEARED. 74 SOLAS (14) II-2/4.5.5.1.1 FSS CODE 15.2.2.1.1 17a 10c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2021
Resolved 27 July 2021
Resolution: CREW REPLACED INOPERABLE SENSOR WITH WORKING SENSOR TESTED, SAT 10c
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 22 March 2019 Resolved
THE INERT GAS SYSTEM SHALL BE CAPABLE OF INERTING, PURGING AND GAS FREEING EMPTY TANKS AND MAINTAINING THE ATMOSHPERE IN CARGO TANKS WITH THE REQUIRED OXYGEN CONTENT. CREW WAS UNABLE TO START IGG OR BLOWER MOTORS FOR OPERATIONAL TEST AND ALARM/SHUTDOWN TESTING. AFTER CARGO IS FINISHED LOADING, WITHOUT AN OPERATIONAL IGG, THE CREW WOULD NOT HAVE THE CAPABILITY TO MAINTAIN THE ATMOSPHERE IN THE CARGO TANKS IF THEY WERE REQUIRED TOPPING OFF INERT GAS. 74SOLAS(14) II-2/4.5.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 April 2019
Resolution: SEC HOU-GAL received satisfactory documentation from BUREAU VERITAS clearing the deficiency.
Engineering › Bilge Water Management System › Not Operational
Issued 18 July 2016 Resolved
50(a,c) - 1700 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention without presenting an unreasonable threat to the marine environment. The vessel's oily water separator is inoperable. MARPOL 73/78, Annex I, Regulation 6.
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 8 August 2016
Resolution: Accepted Bureau Veritas Class Report attesting to operation of OWS system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.