OLD BULL is a 2011 towing vessel. The Coast Guard has recorded 12 inspections since 2013, most recently in July 2026, along with 22 deficiencies — 4 with no resolution recorded —.
Records from 2013 to 2026. Most recent: inspection, 30 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 19.0 ft × 5.5 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMID AMERICA SHIPYARDS · FAIRBANKS, AK, UNITED STATES · built 2011
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton 27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
30 July 2026Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8450936
17 July 2025DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8182870
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2026Resolved
Lifejackets must have the following attachments and fittings:
(1) Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
(2) Each lifejacket must have a whistle firmly secured by a cord to the lifejacket.
None of the lifejackets onboard had lights or whistles.
46 CFR 141.340 (g)(1) & (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2026
Resolved 20 August 2026
Resolution: Lights and whistles added to PFDs.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 6 August 2026No resolution recorded
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns.
The outlet elbow coming out of the turbo chargers on both main diesel engines did not have exhaust lagging.
46 CFR 144.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2026No resolution recorded
The following systems must be equipped with gauges at the machinery location:
(1)Main engine lubricating oil pressure and main engine RPM;
The tachometer on the STBD main diesel engine was not functioning.
46 CFR 143.230 (c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2026
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 6 August 2026Resolved
The owner, managing operator, or master of each towing vessel must maintain the required navigational-safety equipment in a fully-functioning, operational condition.
The chart plotter/radar was not functioning at the beginning of the inspection.
46 CFR 140.620 (b)
Action required: 10 - Deficiency Rectified
Resolved 6 August 2026
Resolution: Battery charger fuse was replaced which allowed the radar/chart plotter to work.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 30 July 2026No resolution recorded
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040.
The vessel only had one disposable type line throwing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 July 2025Resolved
Install guards on both main engine to prevent personal from coming into contact with the Fly wheel and the belt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2025
Resolved 17 August 2025
Resolution: All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2025Resolved
Replace non operational rpm gauge on starboard main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2025
Resolved 17 August 2025
Resolution: all sat
Prove proper operation of the following alarms.
(1) Main engine low lubricating oil pressure;
(2) Main engine high cooling water temperature;
(3) Auxiliary generator engine low lubricating oil pressure;
(4) Auxiliary generator engine high cooling water temperature;
(5) Low hydraulic steering fluid levels, if applicable; and
(6) Low fuel level, if fitted with a day tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 July 2025Resolved
Any portable pump must have sufficient hose length to reach all space on the vessel to be dewatered. Vessel current portable pump is bolted down and doesn’t have a long enough hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2025
Resolved 17 August 2025
Resolution: Vessel has mounted both of the pumps with quick releases to make the pump easy to quickly move.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024Resolved
All fire-detection systems must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section. The fire detection system was not inspected within the past 12 months and was displaying “system trouble alarm”, have fire detection system inspected.
46 CFR 142.240(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2024
Resolution: Fire detection system was service by GMW and in operation.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 July 2024Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The life raft hydrostatic release unit was found broken and installed incorrectly to the painter line and securing strap, replace life raft hydrostatic release.
46 CFR 141.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2024
Resolution: HRU was replaced and properly installed to life raft.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. An unapproved welded repair was conducted to the pressure vessel, remove pressure vessel from service and provide repair plan for replacement pressure vessel to satisfaction of Marine Inspector.
46 CFR 143.205(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2024
Resolution: Air reciever/compressor unit tagged out and to be replaced with "in-kind" unit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing emergency conditions. A generator was installed on deck to supply power to the vessel’s switchboard via the shore-tie connection plug. The switch board installed onboard is only setup with a 50 amp breaker for the machinery space generator and 50 amp breaker for shore tie connection. Provide documentation on when the installation of the generator was installed outside the machinery space and documentation on the generator rating.
46 CFR 143.205(a)
21AUG2024:Electrical drawings from inital construction were provide which indicate the generator outside was not installed at new construction but was completed prior to Subchapter "M" impltementaion. The generator will be considered as exsisting equipment. The operator has contracted an engineering firm to provide plans to permenatly wire the generator to the switch board in lieu of the the shore tie connection from the generator. Deficeincy has been extended to next scheduled dry dock period, 30JUN2025. Operator to provide P.E. approved electrical drawings for verification during dry dock period.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 17 June 2025
Resolution: Generator has been permanently wired to switch board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The bilge/fire pump is connected by a 50 amp breaker and the machinery space generator is protected by a 50 amp breaker. Provide documentation on the bilge/fire pump motor rating and the machinery space generator rating.
46 CFR 143.2205(a)
12JUL2024: The bilge/fire pump is rated at 18 AMPs, replace 50 AMP breaker at switchboard with appropriately rated breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 21 August 2024
Resolution: Company has the pump tagged out and is utilizing self-priming portable pumps in lieu of the fixed system. Installed pump and electrical connections to be removed during upcoming scheduled dry dock period.
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (6) Low hydraulic steering fluid levels. The hydraulic
steering gear system does not have an alarm at operating
Station.
46 CFR 143.230(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 11 July 2024
Resolution: The hydraulic steering gear system has an alarm at operating station, but was improperly labeled. The alarm indicator was properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 July 2024Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine RPM; (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM; (4) Auxiliary generator engine cooling water temperature. Main engine and auxiliary generator engines did not have gauges locally, install gauges locally.
46 CFR 143.230(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 21 August 2024
Resolution: Gauges were installed at the machinery location for main engines and both generators.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2024Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110.
The floating electric water light had the incorrect
battery installed per manufactures instructions, replace
battery with manufacture required battery.
46 CFR 141.360(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 11 July 2024
Resolution: Batteries were replaced with batteries as per manufacture requiments.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024Resolved
Nonmetallic flexible fuel hose is acceptable if it: (i) Is used in lengths of not more than 0.76 meters (30 inches); (ii) Is visible and easily accessible. The generator installed outside of the machinery space is being supplied fuel from nonmetallic flexible fuel hose approximately 20’ in length and located behind shelving. Provide repair proposal for permanent installation of fuel piping for the generator.
46 CFR 143.265(d)
30JUL2024: Received repair plan to replace exisiting non-metalic flexible fuel hose with seamless steel tubeing and synthetic rubber with an inner tube or reinforced with wire braid hoses. Extended deficiency due date unitl 30JUN2025 during upcoming scheduled dry dock period.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 17 July 2025
Resolution: all sat
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 July 2024Resolved
Each towing vessel must be fitted with a general alarm. There is no general alarm on board to notify crew in event of an emergency, provide repair plan to install general alarm as per 46 CFR 143.235 to satisfaction of Marine Inspector.
46 CFR 143.235
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 21 August 2024
Resolution: General alarms installed in accommodations and machinery space with flashing light. All tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 July 2024Resolved
Controls may not be located in any space that could be cut off from the operator in the event of fire in the protected space. A Sea-Fire Model H240 clean agent system was installed on board with the releasing station installed in the protected space. Provide a repair plan to relocate the release station outside the space the system protects to satisfaction of marine inspector.
46 CFR 136.110
46 CFR 95.16-5
26JUL2024: Received repair plan to relocate remote release control outside machinery space. Extended deficeincy due date to 30JUN2025.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 17 July 2025
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 21 July 2020Resolved
Vessel does not have a line throwing appliance approved under 160.040 or auxiliary line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 18 August 2020
Resolution: Received photographic evidence of the presence of the Line Throwing Appliance and auxilary line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 July 2020Resolved
Installed bilge pump for emergency dewatering is unable to take suction.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 7 August 2020
Resolution: Received video from vessel operator demonstrating the operation of the fixed bilge pump.