MAURY USCG vessel records
← All vessels

PACIFIC QUARTZ

PACIFIC QUARTZ is a 2011 tank ship. The Coast Guard has recorded 6 inspections since 2016, most recently in April 2024, along with 1 deficiency and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 19 April 2024.

Built
2011
Last inspected
19 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9573696
1120226
Flag
LIBERIA
Maury page id
psix-1120226

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2016–2024)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it28778 - Convention (Subpart B), Gross Ton
12680 - Convention (Subpart B), Net Ton
47941 - Dead Weight, Metric Ton
58025 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 6

19 April 2024 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897788
26 May 2023 COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7697110
28 May 2022 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7459131
14 September 2020 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7055100
10 June 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6439356
16 March 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5834469

Deficiency record · 1

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2024 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED CRACKED AND BROKEN INTRINSICALLY SAFE LIGHTING IN THE CARGO PUMP ROOM. 74 SOLAS (20) II-I/45.11
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2024

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.