Records from 2016 to 2026. Most recent: inspection, 30 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2026
Resolved
A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. Vessel's flammable vapor detection system has an inoperable sensor; showing a fault alarm.
46 CFR 182.480(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2026
Resolution: no fault alarm present
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2026
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: An audible alarm that sounds upon discharge. Vessel has an inoperable alarm on the pre-engineered fixed gas fire extinguishing system and is unable to be tested due to corrosion.
46 CFR 181.420(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2026
Resolution: tested sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2026
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. The vessel did not have any servicing report for all of their portable fire extinguishers.
46 CFR 176.810(b)(1)(iv)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2026
Resolution: portable extinguishers had a tag with inspection dated Jul 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 July 2026
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator must hold a marine radio operator permit or higher class license. Vessel's Master does not hold a valid marine operator permit.
47 CFR 80.159(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2026
Resolution: Master provided marine op permit
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 16 July 2026
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have any drill logs onboard.
46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 24 July 2026
Resolution: Ran successful MOB drill and logged it.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 July 2026
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel's VHF-DSC radiotelephone does not have the GPS.
47 CFR 80.905(a)(1)
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 17 July 2026
Resolution: O/O provided pictures of GPS inputted into VHF DSC radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2026
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel had did not have lithium batteries in their waterlight.
46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 23 July 2026
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2026
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Markings of vessel's name was faded and needs to be re-marked.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 23 July 2026
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2026
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Vessel did not have the lanyard secured around the body of the ring life buoy.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 23 July 2026
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 July 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel had expired electronic charts.
46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2026
Resolved 12 August 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 June 2026
Resolved
A pre engineered fixed gas fire extinguishing system must (2) be capable of manual actuation from outside the space... the manual pull cable was corroded/disconnected from the pre engineered system. Repair IAW manufacturing standards and to the satisfaction of the Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2026
Resolution: Serviciing was carried out and cable reconnected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 June 2026
Resolved
A flammable vapor detection system must be provided with procedures for checking the proper operation of a flammable vapor detection system at the operating station. Provide procedures at the op station to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2026
Resolved 12 August 2026
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 31 March 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. Current Captain is not familiar with the pre-engineered fire extinguishing system as it was not installed in accordance with the regulations; emergency instructions for firefighting and man overboard are not in accordance with the equipment and installations on board.
46CFR185.420(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2025
Resolution: Captain and deckhand have been proficiently trained and understand how to maintain and operate the system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Vessel does not have water light on board; water must be attached to buoy with a 3’ to 6’ line and a corrosion resistant clip to allow the the waterlight to be quickly disconnected from
the buoy.
46CFR180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2025
Resolution: Proper light was installed on board.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 March 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector, a light to indicate discharge, and an audible alarm that sounds upon discharge. Current installed system is not in accordance with the regulations.
46CFR181.420
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2025
Resolution: New pre-engineered system was satisfactoriy installed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. Vessel’s audible and visible bilge alarms are not functioning.
46CFR182.520(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2025
Resolution: All bilge audible and visible alarms were repaired and witnessed operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 March 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry three hand orange smoke distress signals. Vessel only has 2 smoke flares on board.
46CFR180.68(b)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2025
Resolution: Additional smoke flares have been placed on board.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 31 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instructions for emergencies and donning life jackets are not posted. There is limited room to post the required items in 46CFR Subchapter T; informed Captain that other required items like the COI and Stability letter could be kept in a binder.
46CFR185.510(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2025
Resolution: All instructions have been placed on board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 March 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel does not have portable lights.
46CFR183.430
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2025
Resolution: 02 flashlights have been placed on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel does not have fire buckets on board.
46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2025
Resolution: Fire buckets have been placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel’s lifejackets have prior vessel’s name on them.
46CFR185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 9 April 2025
Resolution: Life jackets names have been changed to TARPON II.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 March 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2025
Resolved 22 April 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024
Resolved
Alterations, or modifications made to the structure or arrangements of an existing vessel, that are a major conversion, on or after March 11, 1996, must comply with the regulations of this part. MI found non-approved generator installation on aft deck.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 February 2024
Resolved 21 May 2025
Resolution: Generator deficiency was resolved.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 8 February 2024
No resolution recorded
The following vessels may undergo the simplified stability proof test detailed in § 178.330 of this part, in the presence of a Coast Guard marine inspector. MI found new generator installation on aft deck of vessel estimating weight gain of 290lbs.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 February 2024 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2023
Resolved
A flammable vapor detection sensor must be located above the expected bilge water level in the lowest part of a space containing a gasoline fuel tank when separate from the machinery space. Gasoline fuel tank compartment did not have an installed flammable vapor detection sensor. Provide repair proposal and install approved system. 46 CFR 182.480 (e)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 16 March 2023
Resolution: Vapor detector was installed properly. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2023
Resolved
A space containing fuel tanks for gasoline must have a ventilation system that consists of at least two natural ventilation supply ducts located at one end of the space and that extend to the lowest part of the space or to the bilge on each side of the space; and mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Fuel tank compartment has inadequate ventilation; natural ventilation supply did not extend to lowest part of the space and no mechanical ventilation is provided meeting the required air changes. Provide repair proposal and install approved system. 46 CFR 182.460 (a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 25 April 2023
Resolution: Mechanical ventilation is not applicable. Supply duct was installed correctly. Ventilation was found satificatory. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window and continued to operate. Annual was completed outside of window.46CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 January 2023
Resolution: USCG inspectors conducted annual inspection and endorsed COI on 30JAN2023.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Fuel tank compartment protected by pre-engineered fixed fire system lacked closure devices for natural ventilation piping.46 CFR 182.460(L)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 1 March 2023
Resolution: Ventilation closure devices installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Port and Stbd gasoline fuel tank vents had improperly installed flame screens which were pushed into vent.46 CFR 182.450(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 25 April 2023
Resolution: Flame screens were installed on the vents. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 January 2023
Resolved
Rail courses or the equivalent must be installed between a top rail required and the deck so that no open space exists that is more than 305 millimeters (12 inches) high. Vessel was missing two courses of chains at embarkation points.46 CFR 177.900(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 25 April 2023
Resolution: Courses were installed. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2023
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Exposed wire ends were found connected to the marine VHF radio.46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 25 April 2023
Resolution: Exposed wiring was properly secured. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel remote shutoff valves were not labeled.46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 1 March 2023
Resolution: Valves were labeled. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 January 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel's portable hand bilge pump suction hose was cracked.46 CFR 182.520(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 1 March 2023
Resolution: Vessel obtained new hand pump; all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 January 2023
Resolved
Abandon ship and man overboard drills and training documentation shall include the date of drill and the general description of scenario and training topics. Documentation shall be available for review by the Coast Guard upon request. Vessel did not have adequate records for drills.46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 1 March 2023
Resolution: Vessel conducted satisfactory drills and provided records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 January 2023
Resolved
Firefighting drills and training documentation shall include the date of drill and the general description of scenario and training topics. Documentation shall be available for review by the Coast Guard upon request. Vessel did not have adequate records for drills.46 CFR 185.524(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 1 March 2023
Resolution: Vessel conducted satisfactory drills and provided records.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 February 2021
Resolved
Annual inspection of the pre engineered system and one portable extinguisher was not completed. Certified inspector must complete annual inspection of the fixed fire fighting system and one portable extinguisher, provide documentation for the same, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2021
Resolved 11 February 2021
Resolution: Received, reviewed and accepted documentary and photographic evidence showing completion of annual inspection of the FF system. Inspection completed by third party tech IWS Gas and Supply Company. One Portable extinguisher replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2021
Resolved
Discovered a cracked cover to a battery cable electrical connection box. The crack in the box cover exposed the internal connections to water and possibly gasoline fumes from the nearby gasoline tank. This condition is creating a fire and electrical hazard. Replace the cover to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2021
Resolved 11 February 2021
Resolution: Operator replaced damaged electrical connection box cover with a new cover.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 February 2021
Resolved
The page 1 and 2 of the original stability letter was not posted or onboard. Locate or attain copy of the issued stability letter and post on board as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2021
Resolved 11 February 2021
Resolution: Original stability was lost. Operator requested and was issued certified true copy of original stability letter for posting on board.
Stability › Intact Stability (when using lifting gear) › General
Issued 9 November 2016
Resolved
When necessary for safe operation, the cognizant OCMI may place specific stability estrictions on a stability letter or COI. OCMI determined the Simplified Stability test on the sister ship [name withheld], Official Number: 1210014 was conducted on a protected route. The vessel operates on a partially protected route.
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Resolution: SST test completed on sistership- WATER EXPRESS II ON: 1210014.
Fire Fighting › Fixed Fire Detection System › Indicator Light
Issued 1 November 2016
Resolved
Indicator light for fixed fire extinguishing system is non-operational. Representative was unable to demonstrate proper testing of fixed-fire extinguishing equipment. The owner/operator must conduct all tests as required by OCMI and make the vessel available for all specific inspections and drills as required by Subchapter H of this part.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2016
Resolved 1 November 2016
Resolution: Vsl provided satisfactory documentation of new indicator light and proper inspection of system by third-party. All sat.