MAURY USCG vessel records
← All vessels

FLAGSHIP IVY

FLAGSHIP IVY is a 2011 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in November 2025, along with 5 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 20 November 2025.

Built
2011
Last inspected
20 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9520869
1120506
Flag
MARSHALL ISLANDS
Maury page id
psix-1120506

Inspections, by type

…with no type recorded7
Years with a record 6 calendar years (2016–2025)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it42816 - Convention (Subpart B), Gross Ton
21937 - Convention (Subpart B), Net Ton
74999 - Dead Weight, Metric Ton
89918 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

20 November 2025 PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8271251
18 November 2025 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8270452
8 May 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7683452
5 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7681445
4 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7682780
3 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7680986
1 May 2023 COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7678530
1 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7678828
1 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679108
26 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676324
13 January 2022 COC-TVE Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7379736
10 October 2018 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6554868
15 August 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6241860
8 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5965467

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 13 January 2022 Resolved
FOR TANKERS OF 20000 DWT AND UPWARDS CONSTRUCTED ON OR AFTER 1JULY2002 BUT BEFORE 1JAN2016, THE PROTECTION OF THE CARGO TANKS SHALL BE AVCHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE FSS CODE. THE ARRANGEMENT OF THE WATER SEAL OR EQUIVALENT DEVICES AND ITS ASSOCIATED FITTINGS SHALL BE SUCH THAT IT WILL PREVENT BACKFLOW OF VAPOR AND LIQUIDS AND WILL ENSURE THE PROPER FUNCTIONING. PSCO OBSERVED 2 X 1 CM HOLE IN THE DECK WATER SEAL DUE TO WASTEAGE.DECK WATER SEAL WAS FOUND ACTIVELY LEAKING DURING EXAM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2022
Resolution: Recieved class report attesting to repairs, condition of class has been issued. Class has approved temporary repair. No further action required, def has been cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 January 2022 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AT THE TIME OF INSPECTION PSCO WAS UNABLE TO WITNESS TEST OF FIXED GAS DETECTION SYSTEM. BOTH 10% AND 30% LEL ALARMS ACTIVATED. HOWEVER, LEL PERCENT CONTINUED TO READ 0.0%.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2022
Resolution: Recieved class report from DNV attesting to the operation of fixed gas detection system. Report reviewed and found satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 January 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2022
Resolution: Recieved class report from DNV attesting to the operation of portable gas detectors. Proper gas was provided and sensors had been replaced in accordance with shoreside technical assistance.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 October 2018 Resolved
07126 Fire Safety The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended and shall be so installed and, protected as to reduce to a minimum and danger to persons on board, due regard being paid to moving parts, hot surface and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected. PSCO observed 1, 2, and 4 fuel injector supply valves were closed. Upon opening valves, excessive fuel leaks were evident. 74SOLAS(14)II-1/26.1 60ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 October 2018
Resolution: Recieved, reviewed, and accepted class report from DNV-GL stating the deficiency had be rectified. No leaks were detected.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 October 2018 Resolved
11113 Life Saving Appliances Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed a ruptured accumulator bladder on the davit system of rescue boat which hindered operational readiness of rescue boat. 74SOLAS(14)III/20.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2018
Resolution: Recieved, reviewed, and accepted class report from DNV-GL stating the deficiency had be rectified. Rescue boat davit accumlator was replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.