Records from 2017 to 2020. Most recent: inspection, 30 November 2020.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 November 2020
Resolved
Emergency generator would not start using batteries. Battery charger was found in the off position on switchboard. Corrected on the spot. Came back to generator and tested satisfactory.
Action required: 10 - Deficiency Rectified
Due 30 November 2020
Resolved 30 November 2020
Stability › Watertight Integrity › General
Issued 12 July 2017
Resolved
1499: Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. Hydraulic valve for #4, STBD Side ballast water discharge pipe is not operational and has been inop for three days according to crew. 74 SOLAS (14) II-1/3-1. 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 13 July 2017
Resolution: Item was addressed and corrected to the satisfaction of the attending Classification Representative.
Stability › Watertight Integrity › General
Issued 12 July 2017
Resolved
9900: Ship shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. The cover of an opening adjacent to clean water tank cover is missing and the crew is unable to answer why cover is missing from emergency escape trunk in engine room. 74 SOLAS (14) II-1/3-1. 17ac.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 13 July 2017
Resolution: Item was addressed and corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Water Fog Applicators › Number
Issued 12 July 2017
Resolved
0720: The following fire-extinguishing appliances shall be provided at least three water-fog applicators. Onboard fire control plan list required three, upon inspection, all three brackets in cargo area were empty and crew unable to provide equipment. 74 SOLAS (14) II-2/20.6.2.2.1. 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 13 July 2017
Resolution: Item was addressed and corrected to the satisfaction of the attending Classification Representative and addressed by Panama.
Construction/Loadline › Markings › Load Line Mark
Issued 12 July 2017
Resolved
1299: Details of marking the ring, lines and letter shall be painted in white or yellow on dark ground or black on a light ground. Details of marking on starboard side illegible due to paint applied, ICLL Reg 8, 401c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2018
Resolution: RCVD CCS RPT, SEE DOCUMENTS
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 12 July 2017
Resolved
9900: Ballast Water: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow. Vessel not maintaining documentation in accordance with Ballast Water Management Plan, Sections 9 for sediment and documentation, 33CFR151.2050(g), IMO Res., 207(62), 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2018
Resolution: RCVD CCS RPT, SEE DOCUMENTS
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 July 2017
Resolved
1930: Hazardous condition either aboard a vessel or cause by a vessel or its operation. The owner, agent, Master, operator or person in charge shall immediately notify the nearest USCG Sector Office. Vessel had alarm failure on x-band radar during transit in San Francisco. Vessel failed to make notification of radar failure and PSC exam team only notified 7 hours after alarm, 33CFR160.216, 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 12 July 2017
Resolution: Company via the agent notified repair company. PSC team spoke with Captain and Superintendent about proper notification.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 12 July 2017
Resolved
2099: Every crewmember shall be given instructions which shall include but not necessarily limited to special instruction necessary for use of ships life saving appliances. Ship's crew could not demonstrate a knowledge of aft escape ladder location for six man life-raft. Additionally, pad eyes were painted to deck and not accessible for use, 74 SOLS (14) III.15.4.2.2, 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 12 July 2017
Resolution: Spoke with Captain, [name withheld], Chief Mate, Chief Engineer and Third Mate about proper training for all crewmembers regarding launching life-rafts.