MAURY USCG vessel records
← All vessels

HISUI

HISUI is a 2010 tank ship. The Coast Guard has recorded 7 inspections since 2018, most recently in June 2026, along with 1 deficiency.

Records from 2018 to 2026. Most recent: inspection, 17 June 2026.

Built
2010
Last inspected
17 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 June 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9405875
9V5325
1123848
Flag
SINGAPORE
Maury page id
psix-1123848

Documentation record

Tonnage as PSIX records it45815 - Convention (Subpart B), Gross Ton
53012 - Dead Weight, Ton
71173 - Displacement, Ton
13745 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

17 June 2026 Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8407167
9 April 2021 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7169483
9 April 2021 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7180205
7 February 2020 PSC C · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6902286
7 February 2020 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7089414
3 December 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6591391
6 November 2018 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6574914

Deficiency record · 1

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2018 Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products [10.1.2]. Electrical equipment should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the Organization [10.1.4]. PSCOs noted two explosion-proof flood lights installed in hazardous area that do not present as original. One (on top of compressor room) is missing one of bolts for explosion-proof junction box and does not have proper explosion-proof plug for un-needed cable entry. Other (on top of deck storehouse) also does not have proper explosion-proof plug and gasket is wasted away, compromising the MESG (Maximum Experimental Safe Gap). *These lights also meet the deck lighting requirements for the transfer area from 33 CFR 155.790* 74 SOLAS 14 VII/13.1 REF IGC 93/10.1.2 and 10.1.4 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 6 February 2019
Resolution: Received class document attesting to the satisfactory repair of listed flood lights.

Ownership record