← All vessels
NAVIGATOR GENESIS
NAVIGATOR GENESIS is a 2011 tank ship. The Coast Guard has recorded 8 inspections since 2018, most recently in January 2025, along with 5 deficiencies and 3 operational controls.
Records from 2018 to 2025. Most recent: inspection, 15 January 2025.
- Built
- 2011
- Last inspected
- 15 January 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9531519 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5DQ3
1124277
Flag
LIBERIA
—
Maury page id
psix-1124277
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2018–2025)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it16823 - Convention (Subpart B), Gross Ton
5046 - Convention (Subpart B), Net Ton
16687 - Dead Weight, Ton
24919 - Displacement, Ton
5046 - Convention (Subpart B), Net Ton
16687 - Dead Weight, Ton
24919 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
15 January 2025
COC-GAS Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8057169
15 January 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7621663
1 July 2022
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7485866
13 March 2020
PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6923417
13 February 2019
COE-Dockside · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6622329
9 February 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6622957
12 December 2018
ISPS II Exam · Administrative Inspection · Deficiency Check · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6594425
11 December 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6595938
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 December 2018
Resolved
Ships in which carriage of flammable products is intended should be fitted with fixed dry chemical powder type extinguishing systems for the purpose of fighting fire on the cargo area. The systems should be capable of delivering powder from at least 2 hand hose lines to any part of the above-deck exposed cargo area including above-deck cargo piping.
Vessel is currently in heel with 130 metric tons of propane, a flammable cargo. PSCOs observed that the #2 DCP hose station's hose is cracked and the #1 DCP hose station's N2 bottle is at 60 bar pressure, where 90 bar is required. Both of these items were noted during the 06JUN2018 shore-side servicing and remain uncorrected to date.
74 SOLAS 14 VII/13.1 REF IGC 93/11.4
07109
30 a/b/c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 December 2018
Resolved
The safety management system should ensure compliance with mandatory rules and regulations [ISM 1.2.3.1]. The Company should ensure that for any non-conformities identified, appropriate corrective action is taken [ISM 10.2.3].
Vessel's COF authorizes 0.28 bar "at sea" and 0.45 bar "in harbor" MARV settings IAW IGC 4.2.6.4, 8.2.6.2, and 8.2.7. From review of the deck log book, vessel departed Point Lisas, Trinidad and Tobago at 2100 on 04DEC2018, but the "in harbor" setting was not removed until 0930 on 06DEC2018, while vessel was at sea in Caribbean enroute Houston. This provides objective evidence that "in harbor" MARVS were used at sea in direct violation of IGC 93/4.2.6.4. Vessel's MARV changing procedure, Document P23, states "the cargo tank is designed for a maximum internal pressure of 0.28 bar during sea condition. Therefore the set point of the safety relief valves should be adjusted down to 0.28 bar prior leaving harbour."
As denoted in deficiency #1, the deficient condition of the DCP hose #2 and N2 pilot cylinder #1 was noted in 06JUN2018 technician's report, but no corrective action was taken.
The fixed gas detection system has been operating erratically since 10OCT2018. The same was reported by the Chief Mate on many occasions, but appropriate corrective action has not been taken.
74 SOLAS 14 IX/3.1 REF ISM 1.2.3.1 and 10.2.3
15109
30 b/c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 12 December 2018
Resolved
Gas detection equipment acceptable to the Administration should be provided. According to Salwico SW2020 manual, the operating panel must display, in clear text, the sampling point and last measured value.
Fixed gas detection display is showing a variety of random symbols and characters, constantly changing, making the display not properly legible.
Additionally, ship's drawing no. 015 for Hull Nos. 2351-2356, shows the system should be fitted with a ST600 catalytic sensor. The system is currently fitted with a GD 10 infrared sensor. Administration [or RO] to confirm that change in sensor is acceptable, and if so, drawing to be appropriately updated to reflect onboard equipment.
74 SOLAS 14 VII/13.1 REF IGC 93/13.6.1
06105
17 a/c
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 December 2018
Resolved
Maintenance, testing, and inspection of firefighting equipment shall be carried out based off the guidelines developed by the Organization [MSC Circ. 1432]. MSC Circular 1432 Section 8.2.4 requires that a sample of the dry powder be tested for moisture content every 2 years.
Last DCP moisture analysis is from June 2016. DCP servicing was carried out in June 2018 but no moisture analysis of a sample was performed.
74 SOLAS 14 II-2/14.2.2
50c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 December 2018
Resolved
Cargo compressor rooms should be fitted with mechanical ventilation systems. Provisions should be made to ventilate such spaces prior to entering the compartment. Mechanical ventilation inlets and outlets should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable vapors and to ensure safe working environment, but in no case should the ventilation system have a capacity of less than 30 air changes per hour.
Upon entering compressor room, PSCO noted little to no air flow. PSCOs noted no negative pressure/suction at mechanical exhaust point at the bottom of the compressor room. It was subsequently determined that a fire damper (on the mechanical extraction vent trunk on the roof of the compressor room) was closed and thus, although the mechanical extraction fan was running, no air was being mechanically extracted from the space.
74 SOLAS 14 VII/13.1 REF IGC 93/12.1
10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National