LISTA is a freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in May 2024, along with 14 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2024. Most recent: operational control imposed, 24 May 2024.

Built
Not recorded
Last inspected
24 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2024
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9514030
V7A2502
1124967
Flag
MARSHALL ISLANDS
Maury page id
psix-1124967

Documentation record

Tonnage as PSIX records it31540 - Convention (Subpart B), Gross Ton
18765 - Convention (Subpart B), Net Ton
65878 - Displacement, Ton
55868 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

24 May 2024 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918544
6 May 2024 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7907222
21 January 2022 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7381048
11 May 2020 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6947832
12 May 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6409916
29 November 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6049109

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 May 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO determind that while getting underway the engineer on watch had No. 1 Main Start air isolated and when low pressure alarm for No. 2 Main Start Air went off, the engineer opened the cross valve which subsequently emptied No. 1 causing another low pressure alarm. It was subsequently identified that only air compressor No. 2 was in standby. 74 SOLAS 20 II-1/26.1
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 24 May 2024
Resolved 25 May 2024
Resolution: Received satisfactory class report attesting to the satisfactory operation of the air compressor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 24 May 2024 No resolution recorded
The Company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the Company. The operational nature of the deficiency noted above provides objective evidence of a serious failure of the implementation of the ISM Code. While questioning the Engineering department related to deficiency No. 1, PSCO found the "presailing check list" was not completed prior to getting underway from Belle Chasse Anchorage. When C/E was asked what the "plant operating instructions" on action 8 of the presailing check list was, C/E could not provide and was unfamiliar. Request external audit is conducted within 90 days. ISM Code 10.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 6 May 2024 Resolved
Found 02 EEBD Discharged in Engine Room. Ships Spares were used as replacements.
Action required: 10 - Deficiency Rectified
Due 10 May 2024
Resolved 10 May 2024
Resolution: Ships spares were used as replacements
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2024 Resolved
The flammable liquids must be in containers of 3.8L (1 Gallon) or less. Found 04 containers of flammable liquids in excess of 1 gallon.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 May 2024
Resolution: Vessel provided photographs showing proper stowage of flammable cargo.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 January 2022 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed a fuel oil leak on the number 5 cylinder of the Main Diesel Engine, 02 buckets placed under the fuel oil transfer pump to catch fuel, and an accumulation of oil sludge in the bilge 74 SOLAS 20 II-2/4.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2022
Resolution: Replacement of the rope packing for the pump installed. Class approved repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 January 2022 Resolved
The arrangements for the storage, distribution and utilization of other flammable oils employed under pressure in power transmission systems, control and activating systems and heating systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed a non permanent hose fixed between 2 metal pipes that transfers fuel oil. 74 SOLAS 20 II-2/4.2.4 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2022
Resolution: Removed the pipe as it is not in accordance with the ships drawing. Class approved removal.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 January 2022 Resolved
fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. Heat detector in ships machine shop is non operational. 74 SOLAS 20 II-2/4.2.1.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2022
Resolution: Removed the malfunctioning heat detector and replaced with the new heat detector from ships’ spares. Class approved repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed active leaks on the ships main salt water service pump and top side tank ballast pipe. 74 SOLAS 20I/11(a) - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2022
Resolution: Replaced the packing on the salt water service pump and installed new gasket in way of the leaking flange of the top side ballast pipe. Class approved repairs.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 21 January 2022 Resolved
The master, owner, operator, agent, person in charge, or responsible officer's printed name, title, and signature attesting to the accuracy of the information provided and that the activities were in accordance with the ballast water management plan. The Ships Ballast Water Record Book requires all ballast water treatment operations be recorded. Ballast water treatment operations have not been recorded. 33 CFR 151.2070(2) - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2022
Resolution: Master and Chief officer received training on how to properly fill BWTS logbook and system use.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 May 2020 Resolved
ANY SHIP 10,000 GROSS TONNAGE AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT APPROVED BY THE ADMINISTRATION AND SHALL BE SUCH AS WILL ENSURE THAT ANY OILY MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAVING AN OIL CONTENT NOT EXCEEDING 15 PPM. PSCO OBSERVED INOPERABLE OIL WATER SEPERATOR AND UNABLE TO BE TESTED BY [name withheld] I/REG 14.6
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2020
Resolved 16 May 2020
Resolution: The ships crew has carried out repair to the OWS by repairing stuck solenoid valve. The OWS has now been fully tested in the presence of the attending surveyor with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 May 2020 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. DURING ATTEMPTED TEST OF OWS, PSCO OBSERVED APPROXIMATELY 80 GALLONS OF DIRTY OIL LEAK OUT OF THE OIL SEPARATION TANK DUE TO MANHOLE COVER NOT BEING SECURED. LEAK WAS CAUSED BY OWS. 74 SOLAS (2014) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2020
Resolved 16 May 2020
Resolution: The ships crew has secured the bolted cover to the oil separation tank. The attending surveyor has confirmed same at this time. Surveyor also confimed bilge is free of oil.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 11 May 2020 Resolved
EVERY COMPANY SHOULD DEVELOP, IMPLEMENT, AND MAINTAIN A SAFETY MANAGEMENT SYSTEM WHICH INCLUDES PROCEDURES FOR REPORTING NON-CONFORMITIES. PSCO OBSERVED THREE SOFT PATCHES ON CARGO HOLD BALLAST PIPES, TWO SOFT PATCHES ON BILGE SUCTION PIPES, AND ONE SOFT PATCH ON A BOILER CONDENSOR PIPE. THE PATCHES WERE NOT REPORTED TO THE COMPANY AS PER THE VESSEL'S SMS SECTION 13.2. 74 SOLAS (14) IX/3.1 ISM CODE PART A 1.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2020
Resolved 16 May 2020
Resolution: The ships’ crew has generated deficiency report in accordance with the SMS and the same has been confirmed by the attending surveyor.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2020 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE WHICH THEY ARE INTENDED. PSCO OBSERVED THREE SOFT PATCHES ON CARGO HOLD BALLAST PIPES, TWO SOFT PATCHES ON BILGE SUCTION PIPES, AND ONE SOFT PATCH ON A BOILER CONDENSOR PIPE. 74 SOLAS (14) 11-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2020
Resolved 16 May 2020
Resolution: The ships’ crew has carried out permanent repair of the identified leaking piping by removing the temporarily repaired section and welding new section in place. The new piping has been tested under operational pressure in the presence of the surveyor.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 May 2020 Resolved
EACH OPERATION SHALL BE FULLY RECORDED IN THE OIL RECORD BOOK SO THAT ALL ENTRIES APPROPRIATE TO THAT OPERATION ARE COMPLETED. DURING EXAMINATION OF OIL RECORD BOOK, PSCO OBSERVED AN OILY WATER SEPARATOR DISCHARGE THAT WAS ONE CUBIC METER GREATER THAN THE MAXIMUM THROUGHPUT FOR FOUR HOURS. MARPOL ANNEX I/17.4
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: [name withheld] TO EXPALIN THE 9.1 CUBIC METER THROUGHPUT. SPOKE TO HIM ABOUT MAKING ACCURATE AND APPRORIATE ENTRIES.

Ownership record