MAURY USCG vessel records
← All vessels

BERNIS

BERNIS is a 2012 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in March 2025, along with 4 deficiencies and 2 operational controls.

Records from 2017 to 2025. Most recent: inspection, 29 March 2025.

Built
2012
Last inspected
29 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 March 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9498298
V7A4383
1126674
Flag
MARSHALL ISLANDS
Maury page id
psix-1126674

Documentation record

Tonnage as PSIX records it22549 - Convention (Subpart B), Gross Ton
17464 - Simplified, Gross Ton
44892 - Displacement, Metric Ton
35995 - Dead Weight, Metric Ton
12444 - Convention (Subpart B), Net Ton
17464 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

29 March 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8101696
25 March 2024 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7880471
15 August 2022 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7532235
11 March 2021 PSC B · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7148924
4 March 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7149852
11 December 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6871669
11 December 2019 ISM Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6872254
18 April 2019 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6662068
31 July 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6225971
30 July 2017 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6224958
25 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6220332

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 March 2024 Resolved
Oil fuel pipes shall be capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which tanks are situated. PSCO observer wire connected to fuel shut off valve parted while being pulled. 74SOLAS(20) II-2/4.2.2.3.4 - 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 March 2024
Resolved 27 March 2024
Resolution: PSCO observed new wire installed to emergency diesel generator fuel shut off valve. Upon satisfactory observation of operational test of fuel shut off valve, deficiency cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 11 December 2019 Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with national and international requirements; and appropriately manned in order to encompass all aspects of maintaining safe operations on board. Vessel Master who reported 04DEC2019 was relieved of duties after being found intoxicated while getting vessel underway. Vessel currently does not have master onboard to meet safe manning requirements. Cite: 74SOLAS(14) IX/3.1, ISM CODE 6.2. 74SOLAS(14)V/14.2. Code 60b.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 December 2019
Resolution: Received copy of the ISM audit and acceptance from flag of the audit also new master arrived and credentials and licenses checked.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 11 December 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2019
Resolution: Received copy of the ISM audit and acceptance from flag of the audit also new master arrived and credentials and licenses checked.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 July 2017 Resolved
74SOLAS (14 Cons.) II-1/26.1. The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. No. 4 cylinder on main engine is experiencing excessive jacket water leakage.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2017
Resolved 7 August 2017
Resolution: Class report provided. Deficiency cleared.

Ownership record