Records from 2016 to 2026. Most recent: inspection, 6 February 2026.
Inspection history · 8
6 February 2026
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8305965
23 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8023711
17 April 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7896696
28 September 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7567702
22 September 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7564073
13 September 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6805470
20 August 2018
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6509097
18 August 2016
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5975966
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 February 2026
Resolved
All lifesaving appliances and arrangements shall comply with the applicable code.
The normal equipment of each lifeboat shall consist of a food ration for each person the liferaft is permitted to accomodate. These rations shall be kept in air tight packaging. PSCO found 31 airtight rations and 05 rations that were not air tight. 34 are required.
74SOLAS(20)III/34
LAS Code 4.4.8.12
Action required: 15 - Rectify deficiencies by next port
Resolved 24 March 2026
Resolution: Received satisfactory class report attesting to the ship receiving new lifeboat provisions. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 6 February 2026
Resolved
The ring, lines, and letters shall be painted in white or yellow on a darkground. PSCO observed that the deckline and background are both painted blue.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 March 2026
Resolution: Received class report attesting to the ships crew painting hull markings. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2024
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: thermal insulation at boundaries shall have due regard to the fire risk of the space and adjacent spaces. PSCO observed missing A-60 insulation along portside bunkering station doorframe.
74SOLAS II-2/9.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2024
Resolution: Received DNV class report attesting to successful repairs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2024
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed both emergency generator and engine control room telephones with exposed wiring.
74SOLAS II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2024
Resolution: Received DNV class report attesting to successful repairs. The damaged cable for the phones were replaced and found to be in order.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 13 September 2019
Resolved
Piping to and from sludge tanks shall have no direct connection other than the standard discharge connection. The PSCO discovered an non-standard connection welded on the discharge side of the sludge pump that was fixed with a valve and a rubber hose.
Action: 17ac
MARPOL Annex I Reg.12.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2019
Resolution: Survey report provided by class attesting to remedy of deficiency. Additional connection was blanked off and welded with piece of plate. Permanent new pipe spool was prepared and to be installed before arriving at the next port.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 September 2019
Resolved
Fuel tanks with a capacity greater than 500l shall be fitted with a quick closing valve. The quick closing valve on the HFO service tank was found blocked with a piece of wood.
Action: 10c
74 SOLAS (14 cons.) Ch.II-2 Reg.4.2.2.3.4
Action required: 10 - Deficiency Rectified
Resolved 14 September 2019
Resolution: Crew removed wood block on quick closing valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2019
Resolved
Firefighting systems and appliances shall be kept in good working order. The fire hose in the Engine Room was found dry rotted and not in good working order.
Action: 10c
74 SOLAS (14 cons.) Ch.II-2 Reg.14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 14 September 2019
Resolution: Crew replaced fire hose.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 18 August 2016
Resolved
2510 - Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently is not following Bio-Fouling Management Plan as required by 33CFR 2050(g) reference and IMO MEPC Resolution 207(62). 33CFR 2050(g) and IMO MEPC Resolution 207(62) -(10c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: Vessel was advised about Bio-Fouling recordkeeping in accordance with 33CFR 2050(g) and IMO MEPC Resolution 207(62)