← All vessels
VIOLET RAY
Freight Ship · Ro-Ro Cargo Ship class · Built 2010s · USCG Southwest District (CGD-SW) · Other hulls named VIOLET RAY
VIOLET RAY is a 2010 freight ship. The Coast Guard has recorded 10 inspections since 2012, most recently in February 2026, along with 8 deficiencies.
Records from 2012 to 2026. Most recent: inspection, 6 February 2026.
- Built
- 2010
- Last inspected
- 6 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9395630 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6XG3
1126763
Flag
BAHAMAS, THE
—
Maury page id
psix-1126763
Inspections, by type
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it29324 - Displacement, Ton
49708 - Convention (Subpart B), Gross Ton
14913 - Convention (Subpart B), Net Ton
13370 - Dead Weight, Ton
49708 - Convention (Subpart B), Gross Ton
14913 - Convention (Subpart B), Net Ton
13370 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
6 February 2026
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8305965
23 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8023711
17 April 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7896696
28 September 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7567702
22 September 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7564073
13 September 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6805470
20 August 2018
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6509097
18 August 2016
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5975966
4 November 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5755006
27 June 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4351156
Deficiency record · 8
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 February 2026
Resolved
All lifesaving appliances and arrangements shall comply with the applicable code.
The normal equipment of each lifeboat shall consist of a food ration for each person the liferaft is permitted to accomodate. These rations shall be kept in air tight packaging. PSCO found 31 airtight rations and 05 rations that were not air tight. 34 are required.
74SOLAS(20)III/34
LAS Code 4.4.8.12
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 6 February 2026
Resolved
The ring, lines, and letters shall be painted in white or yellow on a darkground. PSCO observed that the deckline and background are both painted blue.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2024
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: thermal insulation at boundaries shall have due regard to the fire risk of the space and adjacent spaces. PSCO observed missing A-60 insulation along portside bunkering station doorframe.
74SOLAS II-2/9.1.2
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2024
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed both emergency generator and engine control room telephones with exposed wiring.
74SOLAS II-1/45.1.3
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 13 September 2019
Resolved
Piping to and from sludge tanks shall have no direct connection other than the standard discharge connection. The PSCO discovered an non-standard connection welded on the discharge side of the sludge pump that was fixed with a valve and a rubber hose.
Action: 17ac
MARPOL Annex I Reg.12.3
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 September 2019
Resolved
Fuel tanks with a capacity greater than 500l shall be fitted with a quick closing valve. The quick closing valve on the HFO service tank was found blocked with a piece of wood.
Action: 10c
74 SOLAS (14 cons.) Ch.II-2 Reg.4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2019
Resolved
Firefighting systems and appliances shall be kept in good working order. The fire hose in the Engine Room was found dry rotted and not in good working order.
Action: 10c
74 SOLAS (14 cons.) Ch.II-2 Reg.14.2.1.2
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 18 August 2016
Resolved
2510 - Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently is not following Bio-Fouling Management Plan as required by 33CFR 2050(g) reference and IMO MEPC Resolution 207(62). 33CFR 2050(g) and IMO MEPC Resolution 207(62) -(10c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.