MAURY USCG vessel records
← All vessels

OSLO BULK 4

OSLO BULK 4 is a 2010 freight ship. The Coast Guard has recorded 35 inspections since 2016, most recently in July 2026, along with 11 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 31 July 2026.

Built
2010
Last inspected
31 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 July 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9589956
CQ2853
1126795
Flag
PORTUGAL
Maury page id
psix-1126795

Documentation record

Tonnage as PSIX records it5629 - Convention (Subpart B), Gross Ton
8039 - Dead Weight, Metric Ton
11069 - Displacement, Metric Ton
2867 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

31 July 2026 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8451425
9 June 2026 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8397311
17 April 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8350976
26 February 2026 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8316690
28 November 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8274829
17 October 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8251267
27 July 2024 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7967521
22 June 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7939947
19 April 2024 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7894184
1 April 2024 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7885939
13 March 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7878593
6 March 2024 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872686
5 January 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7845604
30 September 2022 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7569214
29 September 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7565700
2 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7466209
19 February 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7398731
19 February 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7399194
16 March 2021 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7151382
18 September 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7061602
11 September 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6807250
7 September 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6800548
1 August 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6769441
22 April 2019 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6662518
16 April 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6663510
5 January 2019 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6605892
9 August 2018 NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6505484
1 August 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6498921
9 March 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6367407
30 October 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6293355
26 April 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6134699
15 November 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6041831
10 November 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6038865
14 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6021683
11 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6014925

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 February 2026 Resolved
Fire detection and fire alarm systems shall be kept in good working order so as to ensure their required performance if a fire occurs. PSCO observed damaged smoke detector in workshop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2026
Resolved 27 February 2026
Resolution: Received class report attesting to proper repair
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 26 February 2026 Resolved
Adequate arrangements are in place to ensure that the performance of equipment required by this chapter is maintained. PSCO observed no VDR input for echo depth sounder.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2026
Resolved 27 February 2026
Resolution: Received class report attesting to proper repair
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 26 February 2026 Resolved
The horizontal field of vision from the conning position shall extend over an arc of not less than 225 degrees. PSCO observed shattered forward facing bridge window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2026
Resolved 26 February 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2026 Resolved
The operator of a vessel with a capacity of 250 or more of oil shall provide transfer procedures that meet the requirements of this part. PSCO observed missing information in transfer procedures.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2026
Resolved 16 April 2026
Resolution: SEC NY PSCDO received transfer procedure manual via email.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 February 2026 Resolved
Whenever an accident occurs or a defect is discovered which affects safety or efficiency of equipment, the master or owner shall report immediately to the port state. PSCO observed vessel failed to report damaged window afecting bridge visibility on notice of arrival.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2026
Resolved 26 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2024 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS OF CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION IN ACCORDANCE WITH THE PROVISIONS OF REGULATION XI/1, OR WITH APPLICABLE NATIONAL STANDARDS OF THE ADMINISTRATION WHICH PROVIDE AN EQUIVILANT LEVEL OF SAFETY. VESSEL SELF-REPORTED AN INOPERABLE #2 AUXILIARY GENERATOR. 74 SOLAS (04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2024
Resolved 27 July 2024
Resolution: Received Class report attesting to repairs and witnessed operational auxiliary engine #2
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 April 2024 Resolved
The folowing Fire Protection Systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO discovered that ship does not have equipment on board for testing flame detectors. 74 SOLAS (04) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2024
Resolution: PSCO observed testing of 03 flame detectors with proper equipment.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 April 2024 Resolved
The maintenance plan shall include at least the following pire protection systems and fire-fighting systems and appliances, where installed: fixed fire detection and fire alarm systems. PSCO discovered ship does not have maintenance procedures for testing flame detectors. 74 SOLAS (04) II-2/14.2.2.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2024
Resolution: PSCO observed proper maintenance procedures for testing of flame detectors.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 1 April 2024 Resolved
During preparation and launching, the survival craft, its launching appliances, and the area of water into which it is being launched shall be adequately illuminated by lighting. PSCO observed 4 of 5 embarkation lights inoperable. 74 SOLAS (04) III/16.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2024
Resolution: PSCO observed all embarkation lights operational
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 September 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed 15 of the 19 immersion suits onboard had substantial deterioration of the rubber seal mating surface on the zipper, including multiple suits with liner seams seperated from the suit. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2022
Resolved 30 September 2022
Resolution: Vessel received 15 new SOLAS approved immersion suits. PSCO from Sector Mobile completed onboard verification.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 7 September 2019 Resolved
04118 - Every ship to which Chapter 1 applies shall carry an appropriate atmosphere testing instrument or instruments. PSCO discovered vessel was utilizing personal gas detector intended to be carried by an individual and not capable of remote sampling. - 74 SOLAS(14) XI-1/7 & MSC.1/CIRC.1477 15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2019
Resolution: Attended vessel and verified gas detection equipment was on board and received Class Report attesting to the same.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.