ZANTE DAWN is a 2011 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in November 2025, along with 1 deficiency and 2 operational controls.
Records from 2017 to 2025. Most recent: inspection, 3 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11607 - Convention (Subpart B), Net Ton 22419 - Simplified, Gross Ton 34125 - Dead Weight, Metric Ton 42723 - Displacement, Metric Ton 22419 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
3 November 2025PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8262257
30 October 2025Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8262623
25 March 2024Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7884727
11 March 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7874377
25 May 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6960012
14 April 2020PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6936040
21 June 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6443913
22 June 2017Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6182466
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 June 2017Resolved
0360: To contain a fire in the space of origin, the fire integrity of the division shall be maintained at openings and penetrations. On ceah deck in accomodations, wires are run through cable/duct space decks and bulkheads without proper seal being maintained to contain fire. 74 SOLAS (2014 CONS.) II-2/9.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 June 2017
Resolution: Crew applied material around wire runs to maintain the necessary level of fire protection.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.