Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it51255 - Convention (Subpart B), Gross Ton 31192 - Convention (Subpart B), Net Ton 108706 - Displacement, Ton 93274 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
9 June 2026Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8383599
30 May 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8384307
13 May 2025PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8134749
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 May 2025Resolved
Fire fighting applicances shall be kept in good working order and available for immediate use. PSCO observed damaged hood of fire fighters outfit.
74 SOLAS (24) II-2/14.2.1.2
40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 May 2025Resolved
Means shall be provided to control leaks of flammable liquids. PSCO overserved minor oil leak on sludge pump.
74 SOLAS (09) II-2/4.1.1
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025Resolved
All electrical apparatus shall be so contructed and installed as not to cause injury when handled in normal manner. PSCO observed open live electrical wire near sludge pump.
74 SOLAS (24) II-1/45.1.3
10c
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.