Records from 2016 to 2026. Most recent: inspection, 9 January 2026.
Inspection history · 10
9 January 2026
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8287989
22 August 2023
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7774453
4 April 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7659634
19 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7562446
22 June 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7221557
16 June 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7226360
20 August 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6789144
12 April 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6658500
11 January 2019
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6603770
14 October 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6014700
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2023
Resolved
IN CARGO SHIPS, THERE SHALL BE AN ALERNATE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP. PSCO'S OBSERVED SUBSTANTIAL LACK OF PRESSURE FROM EMERGENCY FIRE PUMP. 74 SOLAS (04) II-2/10.2.2.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 4 April 2023
Resolution: PSCO WITNESSED APPROPRIATE PRESSURE FROM THE EMERGENCY FIRE PUMP PRIOR TO DEPARTING THE VESSEL.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 April 2023
Resolved
CARGO SHIPS SHALL CARRY AT LEAST ONE RESCUE BOAT COMPLYING WITH 5.1 OF THE CODE. RESCUE BOATS SHALL COMPLY WITH THE REQUIREMENTS OF PARAGRAPHS 4.4.1 TO 4.4.7.4. PROVISIONS SHALL BE MADE FOR AHEAD AND ASTERN PROPULSION. PSCO OBSERVED THE INABILITY OF THE RESCUE BOAT TO GO ASTERN. CREWMEMBER HAD TO PHYSICALLY HOLD SHIFT LINKAGE TO STAY ASTERN. 74 SOLAS (20) III/31.2, LSA CODE 5.1, LSA CODE 4.4.6.5
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 5 April 2023
Resolution: Recieved report from class attesting to operation
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 4 April 2023
Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED WHITE OR YELLOW ON A DARK BACKGROUN. PSCO OBSERVED PAINTED OVER LOAD LINE AND PLIMSAL. ICLL REG 8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 22 August 2023
Resolution: Received report attesting to proper amrking of loadline.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 22 June 2021
Resolved
Rudder & operational mode indicators to determine and display rudder angle all to be readable from conning position. Rudder angle indicators on bridge wings were 2 to 6 degrees off rudder angle shown at conning position.
Action required: 10 - Deficiency Rectified
Resolved 14 September 2021
Resolution: Vessel submitted pictures of rudder angle indicators fixed and properly functioning.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 22 June 2021
Resolved
The normal equipment of every lifeboat shall consist of... a food ration, these rations shall be kept in airtight packaging. 20 food rations not airtight onboard freefall lifeboat.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Crew was able to replace all 20 lifeboat food rations while we were still onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021
Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO found breaker on switchboard taped open to prevent tripping.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: PSCO witnessed crew removing the tape holding the breaker open.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021
Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO found front panels off of ballast water control station not guarding crew from potential shock hazards.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Crew reattached the panels on the front of the ballast water control panel.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 12 April 2019
Resolved
VESSELS HULL MUST BE FREE OF FOULING ORGANISMS.
VESSEL HAD EXCESS GROWTH ON HULL.
33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2019
Resolution: PICTURES OF DRYDOCKED VESSEL WITH SANDBLASTED AND PAINTED HULL.
Stability › Watertight Integrity › General
Issued 14 October 2016
Resolved
1270-Doors- Access openings shall be fitted with doors and fitted so that the whole structure is of equivalent strength to the un-pierced bulkhead and weather tight when close. Doors to steering and boiler room are no weather tight. ICLL Annex I/II - 12(1)- 10c
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 14 October 2016
Resolution: Door gasket material was replaced during inspection.