MAURY USCG vessel records
← All vessels

HONG FU

HONG FU is a 2009 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in January 2026, along with 9 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 9 January 2026.

Built
2009
Last inspected
9 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9548550
1128019
Flag
HONG KONG
Maury page id
psix-1128019

Documentation record

Tonnage as PSIX records it40896 - Convention (Subpart B), Gross Ton
76402 - Dead Weight, Metric Ton
88499 - Displacement, Metric Ton
25825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

9 January 2026 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8287989
22 August 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7774453
4 April 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7659634
19 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7562446
22 June 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7221557
16 June 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7226360
20 August 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6789144
12 April 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6658500
11 January 2019 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6603770
14 October 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6014700

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2023 Resolved
IN CARGO SHIPS, THERE SHALL BE AN ALERNATE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP. PSCO'S OBSERVED SUBSTANTIAL LACK OF PRESSURE FROM EMERGENCY FIRE PUMP. 74 SOLAS (04) II-2/10.2.2.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 4 April 2023
Resolution: PSCO WITNESSED APPROPRIATE PRESSURE FROM THE EMERGENCY FIRE PUMP PRIOR TO DEPARTING THE VESSEL.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 April 2023 Resolved
CARGO SHIPS SHALL CARRY AT LEAST ONE RESCUE BOAT COMPLYING WITH 5.1 OF THE CODE. RESCUE BOATS SHALL COMPLY WITH THE REQUIREMENTS OF PARAGRAPHS 4.4.1 TO 4.4.7.4. PROVISIONS SHALL BE MADE FOR AHEAD AND ASTERN PROPULSION. PSCO OBSERVED THE INABILITY OF THE RESCUE BOAT TO GO ASTERN. CREWMEMBER HAD TO PHYSICALLY HOLD SHIFT LINKAGE TO STAY ASTERN. 74 SOLAS (20) III/31.2, LSA CODE 5.1, LSA CODE 4.4.6.5
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2023
Resolved 5 April 2023
Resolution: Recieved report from class attesting to operation
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 4 April 2023 Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED WHITE OR YELLOW ON A DARK BACKGROUN. PSCO OBSERVED PAINTED OVER LOAD LINE AND PLIMSAL. ICLL REG 8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 22 August 2023
Resolution: Received report attesting to proper amrking of loadline.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 22 June 2021 Resolved
Rudder & operational mode indicators to determine and display rudder angle all to be readable from conning position. Rudder angle indicators on bridge wings were 2 to 6 degrees off rudder angle shown at conning position.
Action required: 10 - Deficiency Rectified
Resolved 14 September 2021
Resolution: Vessel submitted pictures of rudder angle indicators fixed and properly functioning.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 22 June 2021 Resolved
The normal equipment of every lifeboat shall consist of... a food ration, these rations shall be kept in airtight packaging. 20 food rations not airtight onboard freefall lifeboat.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Crew was able to replace all 20 lifeboat food rations while we were still onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO found breaker on switchboard taped open to prevent tripping.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: PSCO witnessed crew removing the tape holding the breaker open.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO found front panels off of ballast water control station not guarding crew from potential shock hazards.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Crew reattached the panels on the front of the ballast water control panel.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 12 April 2019 Resolved
VESSELS HULL MUST BE FREE OF FOULING ORGANISMS. VESSEL HAD EXCESS GROWTH ON HULL. 33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2019
Resolution: PICTURES OF DRYDOCKED VESSEL WITH SANDBLASTED AND PAINTED HULL.
Stability › Watertight Integrity › General
Issued 14 October 2016 Resolved
1270-Doors- Access openings shall be fitted with doors and fitted so that the whole structure is of equivalent strength to the un-pierced bulkhead and weather tight when close. Doors to steering and boiler room are no weather tight. ICLL Annex I/II - 12(1)- 10c
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 14 October 2016
Resolution: Door gasket material was replaced during inspection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.