BOTTIGLIERI FLAVIO BORRIELLO is a freight ship. The Coast Guard has recorded 6 inspections since 2015, most recently in November 2019, along with 5 deficiencies and 3 operational controls.
Records from 2015 to 2019. Most recent: inspection, 11 November 2019.
- Built
- Not recorded
- Last inspected
- 11 November 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9426099 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ICRZ
1128088
Flag
ITALY
—
Maury page id
psix-1128088
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it51255 - Convention (Subpart B), Gross Ton
31192 - Convention (Subpart B), Net Ton
31192 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
11 November 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6853348
24 November 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5769534
24 November 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5769551
24 November 2015
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5769632
20 November 2015
Deficiency Check · Administrative Inspection · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5763369
17 November 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5765535
Deficiency record · 5
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 November 2015
Resolved
1730There are claer grounds for believing the crew are not familiar with procedures relating to prevention of pollution by oil. Upon testing the OWS/OCM, crew was unable to demonstrate proper operation of the system. The sample inlet allowed a negligible amount of sample to pass the OCM. Crew thought this was proper operation. MARPOL 73/78 Annex I 17ac
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 November 2015
Resolved
1730 Oil filtering equipment shall be provided with arrangmeents to ensure any discharge is automatically stopped when oil content of effluent exceeds 15PPM. OWS is unable to process bilge water to a content under 15PPM. Crew operated system for 2 hours with unsatisfactory results. MARPOL 73/78 Ann I 14.7 MEPC107.49 17ac
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 20 November 2015
Resolved
1530Means shall be provided to control leaks of flammable liquids. Multiple fuel leaks were found on valves, tank sensors, and flanges IVO the HFO setteling tank and on the HFO bunnker line in the void space immediatly adjacent to the HFO settling tank. 74SOLAS14 II-2/14.1.1 17ac
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 November 2015
Resolved
0720 Fire fighting systems and appliances shall be maintained ready for use. The semi portable fire extinguisher located near the incinerator had a worn and cracked discharge hose. 74SOLAS14 II-2/17.1.1 17ac
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 20 November 2015
Resolved
0710 The ship in all repsects will remain fit to proceed to sea without danger to the ship. Several cracks to the refractory brick and missing refractory were found on the ships incinerator, posing a potential fire hazard to the ship and its crew. 74SOLAS14 I/11(a) 50ac