MAURY USCG vessel records
← All vessels

PATRIOT

PATRIOT is a 2012 tank barge. The Coast Guard has recorded 17 inspections since 2011, most recently in September 2025, along with 3 deficiencies.

Records from 2011 to 2025. Most recent: inspection, 5 September 2025.

Built
2012
Last inspected
5 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1128689
Flag
UNITED STATES
Maury page id
psix-1128689

Inspections, by type

Years with a record 14 calendar years (2011–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)192.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 677 / net 677
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it677 - Simplified, Gross Ton
677 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 17

5 September 2025 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8227831
9 June 2025 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8151659
6 August 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7975377
14 August 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7767764
14 June 2022 Drydock Exam · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7475985
13 August 2021 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7285726
17 July 2020 Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005244
11 June 2020 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973558
25 September 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6820837
12 October 2018 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6559782
12 July 2017 Deficiency Check · Cargo Tank Internal · COI Inspection · Drydock Exam · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6208083
1 July 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6078223
15 July 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5218767
29 June 2015 Periodic Inspection · Deficiency Check · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5167884
1 July 2014 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4906938
30 July 2013 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4668132
14 June 2011 Hull Examination · COI Inspection · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Initial Certification · Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4137257

Deficiency record · 3

Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 18 July 2017 Resolved
If the voltage of a distribution system is less than 1000V, a tank vessel must not have a grounded distribution system. Single pole breakers ID'd w/ 240V Generator Switchboard feeding 120V panel without transformer.
Due 18 August 2017
Resolved 26 July 2017
Resolution: Recieved technician report from General Marine Electric, see document attached to activity.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 29 June 2015 Resolved
Barge's service power system does not have ground detection. Install ground detection iaw provisions within 46 CFR 111.05-23. Cite: 46CFR 111.05-25
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 July 2015
Resolved 15 July 2015
Resolution: Ground detection for the 120v system has been installed.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 29 June 2015 Resolved
During the ISE in 1S Void, a suspected cargo leak was discovered in the 3rd Bay. Cite: 46CFR31.10-21
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2015
Resolved 1 July 2015
Resolution: Performed an air test inspection on the 1S cargo tank and determined that there is no leak. Pressed the 1S cargo tank up to 2psi.

Ownership record