MAURY USCG vessel records
← All vessels

VALLESINA

VALLESINA is a 2009 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in July 2017, along with 3 deficiencies.

Records from 2016 to 2017. Most recent: inspection, 31 July 2017.

Built
2009
Last inspected
31 July 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 July 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9417311
1129788
Flag
ITALY
Maury page id
psix-1129788

Documentation record

Tonnage as PSIX records it60185 - Convention (Subpart B), Gross Ton
109089 - Dead Weight, Metric Ton
127354 - Displacement, Metric Ton
33762 - Convention (Subpart B), Net Ton
60185 - Simplified, Gross Ton
33762 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

31 July 2017 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6226068
18 March 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6106958
3 February 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6082141
4 January 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5789829

Deficiency record · 3

Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 4 January 2016 Resolved
1199 - Other(cargo) - This valve shall be automatically controlled to close as required in paragraph 2.3.1.5. PSCO observed that the Main Gas Regulating Valve to deck was disconnected and did not function automatically. Crew is unabe to follow cargo discharge procedures in regards to maintaining IG system pressure on the cargo tanks. 74 SOLAS (2014) II-2/4.5.6.1 FSS 2.3.1.3.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 6 January 2016
Resolution: Recieved RINA Class report stating that technicians were able to adjust control voltage and repair the GRV. Tested satisfactory and placed into working operation.
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 4 January 2016 Resolved
1199 - Other(cargo) - Arrangements for gas measurements in double-hull spaces and double-bottom spaces. Vessel is equipped with fixed gas sampling and is in fully loaded cargo condition. PSCO's observed that the fixed gas sampling was disabled in all ballast tanks prior to preparation for cargo operations to occur on 07JAN15, was not indicated in manual as normal practice. 74 SOLAS II-2/4.5.7.2.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 5 January 2016
Resolution: Recieved Class report. New procedures will include checklist along with ballasting preperations in order to prevent future gas sampling valves from being shut prior to operations.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 4 January 2016 Resolved
9900 -Other(not clearly hazardous)- The master, owner, agent, or person in charge of a vessel subject to this subpart bound for ports or places of the United States must provide the information required by 151.2070 of this subpart in electronic or written form to the USCG through the NBIC web site. A report hasn't been submitted since June 2015 and is operating in COTP New Orleans. 33 CFR 151.2060
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 January 2016
Resolved 11 January 2016
Resolution: Verified submission of Ballastwater report and provided training to onboard crew and provided guidance about future submissions.

Ownership record