MAURY USCG vessel records Sign in
← All vessels

TROPIC EXPRESS

TROPIC EXPRESS is a 2011 freight ship. The Coast Guard has recorded 22 inspections since 2011, most recently in May 2026, along with 12 deficiencies and 1 operational control.

Records from 2011 to 2026. Most recent: inspection, 8 May 2026.

Built
2011
Last inspected
8 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9510046 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1130671
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-1130671

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2011–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3744 - Convention (Subpart B), Gross Ton
3744 - Simplified, Gross Ton
5226 - Dead Weight, Metric Ton
7608 - Displacement, Metric Ton
1123 - Convention (Subpart B), Net Ton
1123 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

8 May 2026 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8369107
2 April 2025 PSC A
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8102304
22 April 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7180624
7 April 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7170222
16 March 2021 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7154887
3 November 2018 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6573216
12 July 2018 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6476479
14 June 2018 NPV Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6444376
23 May 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6421344
5 June 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6164911
23 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6153095
28 November 2016 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6048320
22 November 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6045698
20 May 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5877602
17 November 2015 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5765329
29 August 2015 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5231941
19 May 2014 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4862501
14 May 2014 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4858454
14 May 2014 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4858915
26 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4391368
3 July 2012 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4365638
1 July 2011 ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4063932

Deficiency record · 12

04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 16 March 2021 Resolved
All ships of 500GT and upwards shall have a gyro-compass heading repeater or other means, to supply heading information visually at the emergency position if provided. Vessels gyro-repeater in the steering gear room is not operational - 74SOLAS(2014) V/19.2.5.2 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 7 April 2021
Resolution: Received technician report stating that the gyro repeater in the steering gear room was replaced with new unit. System was checked and all was found in good working order. MSD Lake Worth has accepted is report. Deficiency Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 March 2021 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs; structural fire protection of openings and penetrations in these divisions. Starboard side engine room emergency escape door frame is wasted with penetrations - 74SOLAS(2014) II-2/14.2.1.1.1 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 28 April 2021
Resolution: Emergency escape door repaired. Class report received.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 14 June 2018 Resolved
EQUIPMENT AND ARRANGEMENTS FOR PILOT TRANSFER INSTALLED SHALL COMPLY WITH STANDARDS ADOPTED BY THE ORGANIZATION, RESOLUTION A.1045(27). PILOT LADDER ARRANGEMENTS ON BOARD WERE FOUND WITH UNEQUALLY SPACED STEPS, SOME STEPS WERE WARPPED AND RUBBER GROMETS HARDWARE WERE LOOSE. 74SOLAS(14) V/23.1.2 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2018
Resolved 11 July 2018
Resolution: Vessel acquired a new pilot ladder IAW regulations and provided documentation to COTP
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2017 Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Coast Guard officer observed several broken rails. Check rails and repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: The damaged rail was definetively repaired by the vessels crew.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 23 May 2017 Resolved
Fixed pressure water spray extinguishing system must comply with provision of the fire safety systems code. Valves over the number 1 and 3 generators were leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: All valves were locked out and the control valves were tested for leakage. The system was placed back in service after satisfactory testing.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 22 November 2016 Resolved
0799- The fire resistant door shall be gas tight and self closing. 01 self closing door for the escape hatch in the Engine room could not self close. Solas 74 Cons Ed 2014 Reg II-2 9.12.2 16(A)(C)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 28 November 2016
Resolution: Received class report.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 22 November 2016 Resolved
1499- Hydroloc power- operated steering gear shall be provided a low level alarm for each hydrolic fluidresevoir. Vessels crew was unable to initiate a low fluid alarm for thier steering pumps.
Condition: Improper/Lack of Maintenance
Due 6 December 2016
Resolved 28 November 2016
Resolution: Received class report.
Operations/Management › Vessel Activity › Cleaning/Stripping
Issued 22 November 2016 Resolved
1499- The condition of the ship and equipment shall be maintained with the provisionspresent regulations to ensure that the ship is in all respects will remain fit to proceed to sea with out danger to the ship or personson board. Large amounts of hydrolic oil was leakingfrom the steering gear. Solas 74 Cons Ed 2014 Ch I Reg II (a) 10(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2016
Resolved 22 November 2016
Resolution: Crew cleaned the floor and drip pans in the steering gear room.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 14 May 2014 Resolved
Vessel failed to submit a Notice of Arrival to meet the required timeline per 33 CFR160.212 prior to entering the Port of Palm Beach.
Action required: 705 - Other - as specified
Resolved 14 May 2014
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 3 July 2012 Resolved
Emergency generator bulkhead A60 boundary insulation is saturated with oil. Replace saturated insulation.
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 26 July 2012
Resolution: Insulation was replaced as required upon inspection.
Fire Fighting › Means of Escape › Blocked
Issued 1 July 2011 Resolved
Emergency escape hatch from steering gear room has wing nut bolt that is locked from rust, preventing egress. Rectify deficiencies prior to next U.S. port after sailing foreign to the satisfaction of Flag Administration and U.S. Coast Guard.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 July 2011
Fire Fighting › Means of Escape › Doorways
Issued 1 July 2011 Resolved
Emergency escape hatch from engine room STBD side and exit door on Port side have hasps on doors for locking from the outside creating a potentially hazardous condition. also, STBD side egress grated platform has no means of securing the platform from falling on crew member. Gasket on exit door must be permanently attached to the door.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 July 2011

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.