Records from 2017 to 2025. Most recent: inspection, 10 July 2025.
Inspection history · 9
10 July 2025
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8182214
21 October 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022007
12 November 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7823466
2 June 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7213138
14 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6684083
8 April 2019
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6655606
14 February 2018
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6350553
1 February 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6081097
14 January 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6070868
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 April 2019
Resolved
11101 - Lifeboats - The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations. The vessel's starboard lifeboat has a 120mm - 130mm long crack in the fiberglass top shell on the forward port bow.
74SOLAS14CON.CHI/REG11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2019
Resolution: MSD Port Canaveral received class report attesting to the repairs of the starboard lifeboat. Report attached to activity.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 January 2017
Resolved
The fixed fire detection and fire alarm system required in paragraph 4.1.1 shall be so designed and the detectors so positioned as to detect rapidly the onset of fire. The smoke detection system was being circumvented over the #3 generator via a hose from a ventilation duct to the detector head. 74 SOLAS (am) II-2/7.4.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 14 January 2017
Lifesaving › Launching Appliances › Lines
Issued 14 January 2017
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The gripes on the port lifeboat were badly frayed. 74SOLAS(AM) III/20.2
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 14 January 2017
Fire Fighting › Combustible Materials › Insulation
Issued 14 January 2017
Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapours. The lagging on the port side of the lower engine room was oil soaked. 74SOLAS(AM) II-2/4.4.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2017
Resolved 1 February 2017
Resolution: Flag Attestation was received and found satisfactory.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 January 2017
Resolved
At least 3 two-way VHF radiotelephone apparatus shall be provided. Such apparatus shall conform to performance standards not inferior to those adopted by the organization. A primary battery needed to beused to verify a VHF radiotelephone's operability. 74SOLA(AM) III/6.2.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2017
Resolved 16 January 2017
Resolution: Received battery invoice from agent and pictures of operable radios.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 January 2017
Resolved
On each tanker of 10,000 GT or more that is subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability. The long range radar was not working properly. 33CFR164.37(B)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 14 January 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 January 2017
Resolved
The safety management system shall be maintained in accordance with the provisions of the international safety management code. Fire detection system was circumvented. Provide corrective action report and service technicians report of proper operation of fire detection system in the engine room. 74SOLAS(AM) IX/5
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 January 2017
Resolved 1 February 2017
Resolution: Flag Attestation and Technician's Report was received and found satisfactory.