THUNDERBIRD is a 2011 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in March 2024, along with 5 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 2016 to 2024. Most recent: operational control imposed, 27 March 2024.

Built
2011
Last inspected
27 March 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 March 2024
…with no type recorded1
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9497335
1135314
Flag
MARSHALL ISLANDS
Maury page id
psix-1135314

Documentation record

Tonnage as PSIX records it79508 - Dead Weight, Metric Ton
43717 - Convention (Subpart B), Gross Ton
26502 - Convention (Subpart B), Net Ton
93287 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

27 March 2024 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7886230
27 March 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7913408
22 March 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7879780
14 December 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7365892
18 April 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6658861
2 August 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5953687

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2024 Resolved
Daily service tank having a capacity of 500l and above, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. PSCO observed ships engineers not capable of demonstrating the operational readiness of remote quick closing valve on EDG day tank. 74SOLAS(am),II-2/4.2.2 60 ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 22 March 2024
Resolved 22 March 2024
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 22 March 2024 No resolution recorded
Every ship of 100 gross tonnage and above, shall carry a garbage management plan which the crew shall follow. PSCO indentified ships crew using ships incinerator to manage garbage. Ships garbage management plan states in appendix I that ships incinerator shall not be used. Requesting clarification from certificate issuing authority to the continued acceptance. MARPOL 73/78 ANNEX V 10.2 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2024 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 March 2024 Resolved
A self contained source of electrical power shall be provided. PSCO observed EDG ampmeter not operational. 74SOLAS (am) II-1 43
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2024
Resolved 22 March 2024
14 - Pollution Prevention › 148 - Ballast Water › Extraordinary Condition Claims
Issued 22 March 2024 No resolution recorded
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations. 33 CFR 151.2025(a) 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2021 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. PSCO observed an electrical conduit box fractured in between cargo holds 02 and 03. Conduct permanent repairs to the satisfaction of certificate issuing authority. 74 SOLAS II-1/45.5.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2024
Resolution: Received, reviewed and accepted class report.

Ownership record