Records from 2018 to 2022. Most recent: inspection, 30 March 2022.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2022
No resolution recorded
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined in accordance with the fire test procedures code. The fire door in the "A" class boundary between the officers mess and pantry had holes in door from the locking mechanism being removed. 74 SOLAS(20) II-2/9.4.2.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2022
No resolution recorded
Fire Doors in Main Vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing. Upper deck stairway access and galley to cold store stairway doors were not self closing. 74 SOLAS(20) II-2/9.4.1.1.5.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 30 March 2022
No resolution recorded
The training manual shall explain the following in detail: Escape systems and appliances. Training manual only addresses one type of EEBD. Vessel has three types of EEBDs onboard.
74 SOLAS(20) II-2/15.2.3.4.7
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2022 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 20 February 2018
Resolved
1410 Propulsion main engine: Means shall be provided to control leaks of flammable liquids. Identified fuel leaks on main engine fuel pumps #1-#5. 74SOLAS(09)II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2018
Resolution: Received, reviewed and accepted class report / proper documentation from ABS stating the deficiency was rectified. Fuel pumps one through five repaired, tested and found satisfactory.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 20 February 2018
Resolved
1499 Other (Prop. & Aux. Machinery): Means shall be provided to control leaks of flammable liquids. Fuel leak on #1 Diesel Generator injector fuel supply line. 74SOLAS(09)II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2018
Resolution: Received, reviewed and accepted class report / proper documentation from ABS stating the deficiency was rectified. Fuel supply line for diesel generator repaired, tested and found satisfactory.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 20 February 2018
Resolved
1499 Other (Prop. & Aux. Machinery): Means shall be provided to control leaks of flammable liquids. Oil found pooling on the #3 diesel generator surrounding the turbo. 74SOLAS(09)II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2018
Resolution: Received, reviewed and accepted class report / proper documentation from ABS stating the deficiency was rectified. Leakage around number three diesel generator surrounding turbo charger repaired, tested and found satisfactory.