MARJORIE C

MARJORIE C is a 2015 freight ship. The Coast Guard has recorded 59 inspections since 2016, most recently in June 2026, along with 43 deficiencies, 3 operational controls and 16 casualty investigations between 2015 and 2023.

Records from 2015 to 2026. Most recent: inspection, 15 June 2026.

Built
2015
Last inspected
15 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2026
…with no type recorded16
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9619684
WHD6745
1135771
Flag
UNITED STATES
Maury page id
psix-1135771

Documentation record

Registered dimensions (L × B × D)667.4 ft × 105.8 ft × 70.6 ft
Registered tonnagegross 47,279 / net 14,183
ITC dimensions (L × B × D)667.4 ft × 105.8 ft × 70.6 ft
ITC tonnagegross 47,279 / net 14,183
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47279 - Convention (Subpart B), Gross Ton
14183 - Convention (Subpart B), Net Ton
27402 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 59

15 June 2026 Administrative Inspection · ACP Annual Oversight · Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8354018
16 December 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284229
30 September 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8244160
12 July 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8187625
15 June 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8159556
7 April 2025 ACP COI Oversight · MTSA/ISPS Verification · Deficiency Check · Re-Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8106405
8 July 2024 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7953571
2 January 2024 In-Service Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7844532
2 January 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7844533
29 December 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7909359
19 December 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7840655
10 November 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7826243
8 November 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7822328
8 November 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7855870
17 July 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7741479
15 May 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690818
5 July 2022 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7439523
21 June 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7483658
21 July 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7263442
21 July 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7276429
6 July 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301532
23 November 2020 ACP Additional Oversight – Risk Assessment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7100463
30 September 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7068898
29 September 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7105972
9 August 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7027486
6 August 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7036813
18 May 2020 Administrative Inspection · Examination of Repairs · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6955637
31 March 2020 Administrative Inspection · Annual Inspection · ACP COI Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937994
4 February 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6903684
4 February 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6903819
3 February 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6902055
6 January 2020 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6882424
8 December 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6874881
6 November 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6850605
5 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6849655
25 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842481
27 September 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847444
8 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6742812
2 July 2019 Deficiency Check · Annual Inspection · ISM Oversight · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6720123
4 February 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6619719
29 January 2019 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6617030
10 September 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6537615
9 July 2018 ACP Periodic Oversight · MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6469979
25 June 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6431560
25 April 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6399191
25 April 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6399529
26 September 2017 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6276295
7 September 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6262138
16 August 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6286733
18 July 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6213818
11 July 2017 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6204955
6 July 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6208417
12 June 2017 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6170836
28 November 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6048845
21 November 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6048883
8 August 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5966144
21 July 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5947906
1 July 2016 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5926250
28 March 2016 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5842372

Deficiency record · 43

04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 12 July 2025 Resolved
Vessel emergency fire pump failed. Send tech report to local OCMI once repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2025
Resolution: Vessel sent tech report to local [name withheld].
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 April 2025 Resolved
No vessel may be navigated unless it has its service and on board the crew complement as required by the COI. During ACP COI oversight found the vessel did not have required Able Body Seaman on board. Vessel is required to submit a request for sailing short or attest to meeting minimum manning on valid COI prior to departing the Port of San Diego. Cite: 46 CFR 15.515
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Vessel fully manned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2024 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the administration. Ship reported that there is a hydraulic leak from the upper steering gear to rudder stock seal. Repair the steering gear's upper seal in accordance with OEM specifications. Repairs shall be to the satisfaction of attending marine inspector or the vessels RO surveyor.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2024
Resolved 9 July 2024
Resolution: Reviewed and accepted survey report from class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2021 Resolved
The Machinery shall be of design and construction adequate for the service for which they are intended. Vessel suffered a reduction in propulsion from a failed Start Air Valve for the #2 Cylinder. Vessel to prove proper operation of the propulsion engine.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: Received Class report attesting to the proper repair and operational testing of the propulsion engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2020 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. Vessel reported an engineering issue with the #3 cylinder on the Main Engine causing the vessel not to exceed dead slow ahead. Prove proper operation of the Main Engine to the satisfaction of attending Class Surveyor. 74 SOLAS (09 Cons) II-1 / 26.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2020
Resolved 1 October 2020
Resolution: Received class and tech reports that M/E is operating properly
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 13 July 2020 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessels emergency fire pump was able to maintain adequate pressure, however was leaking significantly from pump seal. 74 SOLAS (09) II-2/14.2.1.2
Action required: 15 - Rectify deficiencies by next port
Due 23 July 2020
Resolved 13 July 2020
Resolution: Accepted by DNV-GL 7/13/2020.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 July 2020 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/43. The vessel's forward port side emergency liferaft embarkation station is not illuminated. 74 SOLAS (14) III/11.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 July 2020
Resolution: Accepted by DNV-GL 7/13/2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2020 Resolved
Not less than two lifebuoys shall be provided with lifebuoy self-activating smoke signals complying with the requirements of paragraph 2.1.3 of the Life Saving Appliances Code and be capable of quick release from the navigation bridge. Approved lifesaving appliance means carrying an approval granted by the Commandant under subchapter Q (46 CFR 159-165) of this chapter. 74 SOLAS (14) III/7.1.3 U.S. Supplement to DNV GL Rules for Classification of Ships and International Conventions 3.6.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 July 2020
Resolution: Accepted by DNV-GL 7/13/2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 April 2020 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. In accordance with U.S. Coast Guard Marine Safety Information Bulletin 09-20 "Vessel Inspections, Exams, and Documentation", the vessel was issued a temporary COI based upon acceptance of objective evidence from the vessel's owner and/or operator attesting to the vessel being fit for its intended route and service. The vessel's owner or operator shall ensure that the vessel completes a USCG Marine Inspector attended COI Renewal inspection within 90 days of issuance of this CG-835V requirement. Failure to complete a USCG Marine Inspector attended COI Renewal inspection may result in the vessel being restricted from carrying cargo. 46 CFR 176.404
Action required: 705 - Other - as specified
Due 22 July 2020
Resolved 14 July 2020
Resolution: Vessel completed satisfactory ACP COI Oversight Inspection on 13Jul20. All deficiencies rectified on 14Jul20. Deficiency resolved. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions ofthe present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The crew reported that the pump bearing for the s/w cooling pump outfitted with the engine room emergency bilge suction caught on fire rendering the pump non-operational.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Pump rebuilt.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 January 2020 Resolved
Oil fuel pipes, which, if damaged would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valce directly on the tank capable of being closed from a safe position outside the space. The fuel quick closing valve assembly in the 5 deck fire control station is leaking air past the systems relief valve. 74SOLAS(14)II-2/4.2.2.3.4
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2020
Resolved 27 January 2020
Resolution: valve rebuilt and tested satisfactory by DNV-GL
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 January 2020 Resolved
An alarm system shall be provided indicating any fault requiring attention. Main Engine Cylinder Piston Cooling Flow Sensor is not operating as designed. 74SOLAS(09)II-1/51.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 17 January 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 January 2020 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Pressure gauge for emergency fire pump at local control station not operable. 74SOLAS(14)II-1/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2020
Resolved 17 January 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 January 2020 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Two overhead beams found damaged and inset on cargo ramp from deck 2 to deck 1 at frame 122 and 116. Submit repair proposal to crop and renew during vessel's next scheduled drydock in April 2020. 74SOLAS(14)II-1/3-1
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 17 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 January 2020 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection, including fire-resisting divisions, and protection of openings in these divisions. Opening in A-class fire division of fire door BL6 found not in good working order, with the latching mechanism preventing full closure of the door. 74SOLAS(09)II-2/ 14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Fire door adusted and tested, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 6 January 2020 Resolved
The lines shall be painted in white or yellow on a dark ground. Deck line rusted and no longer white. ILLC Reg 8
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Deck line painted
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 January 2020 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall satisfy the following requirements: (.1) the doors shall be self-closing. (.4) hold-back hooks not subject to central control station release are prohibited. Galley A-60 door found with hold-back and unable to self-close. 74SOLAS(09)II-2/9.4.1.1.4
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Hold back removed.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 6 January 2020 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. Starboard lifeboat and starboard liferaft emergency embarkation station lighting found inoperable. 74SOLAS(14)III/11.4
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Lights replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 November 2019 Resolved
Every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration. The MAJORIE C experienced a intermittent failure of steering system. Demonstrate satisfactory operation of steering system prior to departure to class surveyor. Provide report to [name withheld] vessel is prohibited from departing from any port within the Sector San [name withheld] Zone. 74SOLAS(14) II-1/29.1 46CFR182.600 46CFR185.320
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
Resolution: DNV GL survey report provided to [name withheld] lifted and is cleared for departure.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 October 2019 Resolved
Every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration. The MAJORIE C experienced a intermittent failure of steering system 1,050 nautical miles NE of Oahu on 24 October 2019. Demonstrate satisfactory operation of steering system prior to departure. Your vessel is prohibited from transiting in any port within the Sector Honolulu COTP Zone without the assistance from towing vessels of adequate horsepower and maneuverability. Such assistance from towing vessels must be under the direction and control of an individual holding a Merchant Marine Credential (MMC) authorizing them to engage in assistance towing under the provisions of 46 CFR 11.482. 74SOLAS(14) II-1/29.1
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2019
Resolved 29 October 2019
Resolution: Received a DNV-GL class report and a Navtech Technicians steering system report attesting to the proper operation of the vessel's steering system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2019 Resolved
[name withheld] reported a main engine slow down activation due to a deviation alarm for exhaust gas #3 cylinder while underway 400 nm from Honolulu, HI. Crew members removed the exhaust vale and identified a fractured fuel injector. [name withheld] reported that the exhaust valve and forward/aft fuel injectors were replaced in kind. Operator shall provide an ACS/RO report to OCMI attesting to repair of main engine. Master shall ensure adequate size and hp tugs are alongside when transitting in Honolulu Harbor prior to receiving ACS/RO report attesting to repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2019
Resolved 9 July 2019
Resolution: Received report from class verifying proper repair procedures for the main engine. Email with class action attached in docs. All sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 July 2019 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. (ISM Code 6.3) The company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties. Instructions which are essential to be provided prior to sailing should be identified, documented and given. (ISM Code 7) The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Vessel has no procedures, checklists, or familiarization requirements to operate the Oily Water Separator and no personnel on board were able to operate the OWS. Familiarization training is also required as per MEPC.107(49) Paragraph 1.1.5. Objective evidence indicates a serious failure of the implementation of the SMS, an SMC external audit must be carried out by the RO prior to this ship being released from detention. 74 SOLAS (2014 Consl.) IX / 3 ISM Code (2014) 6.3 and 7
Action required: 30 - Ship detained
Resolved 3 July 2019
Resolution: DNV-GL conducted Safety Management audit of system related to operation of the Oily Water Separator. Issued non-conformity. See DNV-GL job ID No. 1327920 for report.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 July 2019 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position. Quick-closing valve on the emergency diesel generator fuel tank was unable to be closed from outside the space. 74 SOLAS (2014 Consl.) II-2/4.2.2.3.4
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2019
Resolution: Repaired and demonstrated during inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 2 July 2019 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. MIs identified a soft patch installed and active leak on the condensate drain line from main diesel engine turbochargers. 74 SOLAS (2014) I/11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 July 2019 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids,. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. MIs identified fuel leaks on #3, #4, and #5 cylinders on main diesel engine. 74 SOLAS (2014) II-2/4.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 July 2019 Resolved
Except as provided in paragraphs 3.4.4 and 3.4.5, each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least once every three months during an abandon ship drill. MIs unable to witness proper operation of the lifeboats during the ACP Annual Inspection. Crew shall conduct operational tests of port and starboard lifeboats. 74 SOLAS (2014 Consl.) III/19.3.4.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 July 2019
Resolution: Witnessed operational test of the port side life boat on 09JUL19. Vessel plans to demonstrate operation of the starboard life boat in 2 weeks when they return. 22JUL2019: Witnessed operational test of starboard life boat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2019 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Blow dry compressed air or nitrogen through the discharge piping or otherwise confirm the pipe work and nozzles are clear of any obstructions. This may require the removal of nozzles, if applicable. MSC.1/Circ.1432 8.1.2 74 SOLAS (2014 Consl.) II-2/14.2.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2019 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. MIs identified multi-cable transits (MCTs) which were not correctly installed or tightened on the bulkhead of the engine control room and entering the paint locker. 74 SOLAS (2014 Consl.) II-2/9.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 July 2019 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use… Low pressure CO2 system’s timed closing valve will leak after actuating and partially closing requiring crew to manually close after CO2 has been released into a space. Without closing the CO2 system manually, CO2 would continue to enter the space activated for and all CO2 would be exhausted from low pressure reservoir. 74 SOLAS (2014) II-2/9.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 July 2019 Resolved
Instructions for on-board maintenance of life-saving appliances complying with regulation 36 shall be provided and maintenance shall be carried out accordingly. MI's identified a significant gap between the wedge and new wire rope terminal end and wire rope was replaced not by a manufacturer's representative. 74 SOLAS (2014 Consl.) III / 20.3 74 SOLAS (2014 Consl.) III / 20.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2019
Resolution: Fassmer approved servicing technician attended vessel after Breakwater technician serviced wedge & wire to reduce the gaps. See HIGH SEAS TRADING Company servicing report.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 July 2019 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. (Paragraph 6) Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Vessel was unable to prove proper operation of the OWS built to MEPC.107(49) and received no familiarization training, in accordance with MEPC 107(49) Paragraph 1.1.5, to properly operate the OWS. MARPOL (2018) Annex I/14.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2019
Resolution: Vessel crew proved proper operation of and familiarity with OWS equipment.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 July 2019 Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally exhaust ventilation and closure of ventilator dampers. MI witnessed ventilation dampers not fully closing in the following locations: Aft outboard engine room, all starboard side shell cargo decks natural ventilation, and 05-03 on main deck forward ventilation for cargo hold. 74 SOLAS (2014) II-2/5.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2019
Resolution: Damper closures tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 2 July 2019 Resolved
Flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the administration. In all spaces protected by a carbon dioxide system, except cargo spaces, stopping of the ventilating fans is to be automatically actuated upon operation of the carbon dioxide system. Ventilation shutdown for paint locker did not automatically shut down upon actuating the pressure switch. 74 SOLAS (2014) II-2/6.3.2, US Supplement to DNV Rules (Rev 11)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2019
Resolution: CO2 ventilation shutdown operated satisfactorily.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 11 July 2017 Resolved
The main engine overspeed trip circuitry is improperly activating causing the main engine to shut down before max parameters are met. USCG is requiring Lyngso Marine Tech Rep to attend and truoubleshoot/repair prior to departure from next port in LA.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 5 September 2017
Resolution: Malfunctioning components identified and replaced. Tests conducted and satisfactory on 3 successive voyages.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 11 July 2017 Resolved
Provide an approved PSTP to conduct the main engine overspeed trip automation testing iaw the Manufactures testing procedure. Current procedure does not allow testing to be done unless vessel is underway.
Action required: 705 - Other - as specified
Due 4 September 2017
Resolved 7 September 2017
Resolution: Received a revised DNV-GL approved PSTP to conduct the main engine overspeed trip automation testing iaw the Manufactures testing procedure.
Construction/Loadline › Markings › Load Line Mark
Issued 12 June 2017 Resolved
Starboard side deck mark shall be painted in a contrasting color to the hull.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 June 2017 Resolved
Found stuffing tube missing on junction box for starboard lifeboat limit switch. Electronics in the junction box were found corroded. Clean electrical connections and replace stuffing tube material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Communications › Public Address System › Loudspeaker
Issued 12 June 2017 Resolved
General alarm speaker located in the vicinity of the forward mooring deck is inoperable. Make repairs to general alarm speaker and complete satisfactory operational test of equipment.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 12 June 2017 Resolved
Found cracked welds on support bracket for low pressure CO2 distribution piping located under the stairwell in the low pressure CO2 space. Submit weld repair proposal to OCMI for review and repair piping support brackets once weld procedures are approved by OCMI.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Lifesaving › Launching Appliances › Davit
Issued 12 June 2017 Resolved
Verify approximate distance for measurement location to determine limit switch cut off for lifeboat davits. Prove proper operation of limit switch with minimum distance from stowed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 20 June 2017
Resolution: Received email with documentation from manufacturer on where measurement must be taken, and service report which shows limit switch settings were re-adjusted to stop the davit 200mm from final stowage position.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 12 June 2017 Resolved
Submit PSTP for steering gear loss of phase alarm that complies with 46 CFR 61.40.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Engineering › Steering Gear System › Piping
Issued 12 June 2017 Resolved
Make permanent repairs to hydraulic leaks on the steering hydraulic system piping located between the filter and DCV.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017
Lifesaving › Launching Appliances › Winch Brake
Issued 12 June 2017 Resolved
Conduct a dynamic winch brake test on the starboard lifeboat and submit proof of test to OCMI.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 11 July 2017

Casualty record · 16

29 May 2015Routine · role: Involved in a Marine Casualty · activity 5145026
24 September 2015Routine · role: Involved in a Marine Casualty · activity 5733013
21 November 2016Routine · role: Involved in a Marine Casualty · activity 6048883
6 July 2017Routine · role: Involved in a Marine Casualty · activity 6208417
16 August 2017Routine · role: Involved in a Marine Casualty · activity 6286733
25 April 2018Routine · role: Involved in a Marine Casualty · activity 6399529
27 September 2019Routine · role: Involved in a Marine Casualty · activity 6847444
6 November 2019Routine · role: Involved in a Marine Casualty · activity 6850605
8 December 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6874881
6 August 2020Routine · role: Involved in a Marine Casualty · activity 7036813
9 August 2020Routine · role: Involved in a Marine Casualty · activity 7027486
29 September 2020Routine · role: Involved in a Marine Casualty · activity 7105972
21 July 2021Routine · role: Involved in a Marine Casualty · activity 7276429
8 November 2023Routine · role: Involved in a Marine Casualty · activity 7855870
10 November 2023Routine · role: Involved in a Marine Casualty · activity 7826243
29 December 2023Routine · role: Involved in a Marine Casualty · activity 7909359
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.