Records from 2016 to 2026. Most recent: inspection, 25 February 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATERSPORT INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
25 February 2026
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8316722
13 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209373
23 February 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7869371
5 January 2024
Examination of Repairs · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845651
26 May 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7700683
8 April 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7427301
15 March 2022
Drydock Exam · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412031
17 June 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7228023
14 June 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7224913
17 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7010975
4 March 2020
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6920381
10 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6906432
22 May 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6690593
26 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6491617
5 March 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6365979
15 November 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6307673
5 June 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6167102
8 March 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101411
22 July 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5949411
29 June 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5923761
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2025
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel past due annual inspection date. Vessel not authorized to operate until a marine inspector conducts inspection.
46 CFR 176.500 (b)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Conducted annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 August 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) six hand red flare distress signals... and (2) six orange smoke distress signals. Vessel was missing 02 distress signals.
46 CFR 180.68
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2025
Resolution: received evidence of proper number of flares on board
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 7 March 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspector found 01 adult and 02 child life jackets to be cracked and non serviceable. Replace.
*Passengers allowed is reduced by 01 adult and no children are allowed.8
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Vessel rep [name withheld] emailed pictures of new life jackets. Marine Inspector reviewed and found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 7 March 2024
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designess. Marine Inspector found radio MMSI does not match MMSI assigned on FCC Station License. Update.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2024
Resolution: Vessel rep [name withheld] emailed pictures of MMSI being reprogrammed. Marine Inspector reviewed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 June 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.Vessel only had two fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 14 June 2023
Resolution: photo evidence received of new fire bucket
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 8 June 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Main engine was missing machinery guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 14 June 2023
Resolution: photo evidence received of machinery guard cover installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 June 2021
Resolved
Vessels equipped with radios must display emergency broadcast instruction placard. Vessel had replaced console panel and failed to install new placard. Install new placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 17 June 2021
Resolution: Owner/Operator submitted picture of emergency broadcast placard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 February 2020
Resolved
Vessels hull examination expired on 31DEC2020.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2020
Resolution: Vessel had successful hull exam
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2019
Resolved
Engine room bilge high level alarm sounded, but the light did not illuminate. High level alarms must have audio and visual alarms. Repair high level alarm light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 20 June 2019
Resolution: Replaced alarm indicating component
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 June 2019
Resolved
Navigation charts not up-to-date. Vessel must have updated charts. Update navigational charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 2 July 2019
Resolution: Procured new charts
Fire Fighting › Fire Bucket › Capacity
Issued 17 April 2018
Resolved
Replace 01 fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 26 July 2018
Resolution: Owner provided photograph of 3 Fire Buckets
Communications › Alarms/Indicators › High Water Alarm
Issued 17 April 2017
Resolved
Both high water alarms not working.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 June 2017
Resolution: High water alarms checked and worked.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 April 2017
Resolved
Need current issue of COLREGS.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 April 2017
Resolution: Rule of the roads (NAVRULE) not required.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 April 2017
Resolved
Replace life ring light.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 June 2017
Resolution: Life ring light battery replaced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 April 2017
Resolved
Renew expired Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 June 2017
Resolution: New FCC safet cert issued.
Lifesaving › Lifebuoys › Serviceable
Issued 5 July 2016
Resolved
Life ring needs replacement
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 22 July 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 5 July 2016
Resolved
vessel's forward high water light and bilge pump operation light inoperable. Ensure lights operational
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 22 July 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 July 2016
Resolved
ENG room machinery guard missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 22 July 2016
Documentation › Logs/Records › Logbook (official)
Issued 5 July 2016
Resolved
Life saving and drill logs missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 22 July 2016
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2016
Resolved
Charts outdated must be made current
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 22 July 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 5 July 2016
Resolved
EAP supervisory training required
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 26 July 2016