MAURY USCG vessel records
← All vessels

TBC PASSION

TBC PASSION is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in January 2024, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 29 January 2024.

Built
2011
Last inspected
29 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9594389
1138363
Flag
PANAMA
Maury page id
psix-1138363

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2016–2024)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it38215 - Dead Weight, Metric Ton
46301 - Displacement, Metric Ton
23264 - Convention (Subpart B), Gross Ton
12134 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 9

29 January 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7849689
18 May 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7453677
4 November 2021 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7345378
23 October 2020 PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7069532
5 August 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6501148
31 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6496833
6 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6099571
24 January 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6076032
7 January 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5787026

Deficiency record · 3

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 August 2018 Resolved
0899 - SHIPS SHALL BE PROVIDED WITH ARRANGEMENTS, EQUIPMENT, AND FITTINGS OF SUFFICIENT SAFE WORKING LOAD TO ENABLE SAFE CONDUCT OF ALL TOWING AND MOORING OPERATIONS. WITNESSED FORWARD PORT BREAST LINE TO BE PAST SERVICABLE CONDITION WITH FRAYED STRANDS. - SOLAS 74 (14)/II-1, 3-8.2/ 40C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 December 2018
Resolved 13 August 2018
Resolution: Received documentation of replacement of mooring lines.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 January 2017 Resolved
1499-Other(prop & aux machinery)-The machinery and other pressure vessels associated piping system shall be a design and construction adequate for the service for which they are intended. A welded patch was found on the main seawater cooling pipe to hydraulic pumps for cargo hold hatches and pipe in steering gear room. SOLAS74(09)II-1/26.1 - 50ac
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 6 March 2017
Resolution: Recieved Class report attesting to the repair. Please see attached class report for more info.
Fire Fighting › Self-contained Breathing Apparatus › Alarm
Issued 24 January 2017 Resolved
0799-Other(Fire Fighting equipment)-At least two self-contained breathing apparatuses additional to those required by reg 10.10 shall be provided. One additional SCBA is inoperable. SOLAS74(09)II-2/19.3.6.2 - 50ac
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 6 March 2017
Resolution: Received Class report attesting to replacement. See attached class report for more info.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.