NAVIGATOR GALAXY is a 2011 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in February 2026, along with 6 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 10 February 2026.

Built
2011
Last inspected
10 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 February 2026
…with no type recorded7
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9536363
1140128
Flag
LIBERIA
Maury page id
psix-1140128

Documentation record

Tonnage as PSIX records it16687 - Dead Weight, Metric Ton
24919 - Displacement, Metric Ton
16823 - Convention (Subpart B), Gross Ton
5046 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

10 February 2026 PSC B · COC-GAS Renew
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8305428
29 March 2025 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8098822
14 November 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8034733
14 November 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8045911
11 January 2024 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7845089
26 July 2022 PSC B · COC-GAS Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7512148
23 May 2021 COC-GAS Renew · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199230
29 January 2020 PSC B · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6894738
20 February 2019 Ballast Water Examination · Deficiency Check · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6626437
13 May 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6413122
30 January 2018 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6344841
21 April 2017 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6130190
20 April 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6129341
17 March 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6105911
20 December 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6060666
2 December 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6051632
23 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5884397
29 April 2016 ISPS II Exam · PII Safety Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5865498
4 March 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5827102
5 February 2016 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806331

Deficiency record · 6

12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 10 February 2026 No resolution recorded
Gas detection equipment located in a gas-safe space the exhaust gas from the detector should be discharged to the atmosphere in a safe location. The gas sampling cabinet has been modified after the installation with over a dozen holes drilled through inside the sealed enclosure allowing for the passage of gas sampling into the gas-safe cargo control room. 74 SOLAS (2020) VII/13.1 1993 IGC 13.6.5.2 16 AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 February 2026 Resolved
Non-conducting mats or gratings shall be provided at the front and rear of the switchboard. PSCO observed multiple high voltage switchboards in the engine room without any non-conducting mats or gratings. 74 SOLAS (2020) II-1/45.2 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 February 2026
Resolution: Deficiency rectified while on board. Non-conductive mats were placed in their proper locations.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 July 2022 Resolved
An airlock door should be self-closing. PSCO witnessed airlock door between motor roomand main deck unable to self close. 74SOLAS(2020) VII/13.1 IGC(1993) 3.6.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 July 2022
Resolved 26 July 2022
Resolution: Crew adjusted door to properly close.
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 20 February 2019 Resolved
For the spaces listed in 13.6.7, alarms should be activated for flammable products when the vapour concentration reaches 30% of the lower flammable limit. Crew was unable to verify the fixed gas detection alarms at 30% LEL. Crew was unfamiliar with procedures or testing the low, 20% or high 30% LEL alarms. - 74 SOLAS (2014) VII/13.1 - IGC 13.6.10 - 74 SOLAS (2014) IX/3.1 - ISM Code 7 - 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2019
Resolved 23 February 2019
Resolution: Recieved class report 22FEB19, sensor was replaced. Attended vessel and tested 30% LEL alarms, all sat.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 30 January 2018 Resolved
1870-Special Requirements-Airlock- The doors should be self closing and without any holding back arrangements. Exterior air lock door had hold back. 74 SOLAS (14) VII/13.1 - IGC (93) 3.6.2 - 10 c.
Action required: 705 - Other - as specified
Resolved 30 January 2018
Resolution: Hold back hook wedled to railing was removed.
Construction/Loadline › Markings › Load Line Mark
Issued 30 January 2018 Resolved
1220-Freeboard Marks-The ring, lines and letters shall be painted in white or yellow on a dark ground. Port and starboard loadline paint has faded to same color as hull. ICLL 66 ANNEX I/Reg. 8 - 40 c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2018
Resolution: Submitted pictures verfiying painting of draft marks.