GRAVEL GERTY is a 2012 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in April 2025, along with 9 deficiencies and 1 casualty investigation in 2015.
Records from 2015 to 2025. Most recent: inspection, 16 April 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)47.0 ft × 15.7 ft × 5.1 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWATERMAN WELDING · KANAB, UT, UNITED STATES · built 2012
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portLAUGHLIN, NV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton 13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
16 April 2025Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8105357
25 March 2024Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890723
9 January 2023Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7630116
28 February 2022COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7401375
27 February 2022Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7385068
10 March 2021Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185908
16 June 2020Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992921
26 March 2019Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641442
27 March 2018Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6392782
28 March 2017Deficiency Check · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6101348
6 April 2016Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5846948
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 March 2024Resolved
Provision must be made for closing all supply/exhaust duct openings for a space protected by a fixed gas extinguishing system. Current louvers not able to provide adequate seal to prevent fixed extinguishing system gas from escaping space in the event of a fire. Must rectify to satisfaction of USCG OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 21 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 June 2020Resolved
Prove proper operation of port side engine room bilge alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 June 2020
Resolution: Vessel rep replaced float switch, tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020Resolved
Prove operation of life ring water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2020
Resolution: Vessel rep replaced battery, test sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2020Resolved
Prove operation of stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2020
Resolution: Vessel rep replaced bulb, all sat.
Construction/Loadline › Penetrations › Weld
Issued 27 March 2018Resolved
Weld in forward port compartment has pinhole or small tear above the waterline. Repair weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 11 April 2018
Resolution: Weld repaired.
Construction/Loadline › Penetrations › Weld
Issued 27 March 2018Resolved
Weld in starboard side compartment has pinhole or small tear above the waterline facing inboard. Repair weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 11 April 2018
Resolution: Weld repaired.
Documentation › Certificates/Documents › Stability Letter
Issued 28 March 2017Resolved
Stability letter was not available at time of inspection; obtain letter from Sector San [name withheld] and post IVO operating station.
Due 28 April 2017
Resolved 14 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2017Resolved
Post COI at a location where passengers can easily view.
7 March 2015Routine · role: Involved in a Marine Casualty · activity 5102917
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.