← All vessels
GOOD LUCK
GOOD LUCK is a 2011 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in October 2024, along with 3 deficiencies.
Records from 2016 to 2024. Most recent: inspection, 6 October 2024.
- Built
- 2011
- Last inspected
- 6 October 2024
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9492517
A8ZS4
1140776
Flag
LIBERIA
Maury page id
psix-1140776
Inspections, by type
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it75015 - Dead Weight, Metric Ton
88800 - Displacement, Metric Ton
41074 - Convention (Subpart B), Gross Ton
25643 - Convention (Subpart B), Net Ton
88800 - Displacement, Metric Ton
41074 - Convention (Subpart B), Gross Ton
25643 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
6 October 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8015008
5 October 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7564311
28 July 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7013848
29 January 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6342338
19 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6021596
Deficiency record · 3
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 5 October 2022
Resolved
All ships of 3000 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.5 have a 3 GHz radar or, where considered appropriate by the administration, a second 4 GHz radar. PSCE observed S-Band radar was inoperable. 74 SOLAS (20) V/19.2.7.1
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 5 October 2022
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed unauthorized temporary repair to steam piping located beneath OWS. 74 SOLAS (20) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2020
Resolved
A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces. PSCO observed missing smoke detector head in Purifier room. While conducting test of other smoke detector in Purifier room it failed to operate as intended. 74 SOLAS (2014) II-2/7.4.1.1 40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.